Vertical Forced Air Drying Oven

Ask for Price$0.00

Shipped From Abroad

Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-29
Brands:: Scitek

Description

Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature
Fluctuation(℃)
±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170

Reviews

There are no reviews yet.

Be the first to review “Vertical Forced Air Drying Oven”

Your email address will not be published. Required fields are marked *

Quick Comparison

Vertical Forced Air Drying Oven removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeAutomatic Pipette remove
NameVertical Forced Air Drying Oven removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeAutomatic Pipette remove
ImageDrug Test Cup
SKUSF1033560130127-29SF1033560084-129SF1033560084-6SF1033560084-125SF1033560084-28SF1033560084-130
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature Fluctuation(℃) ±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar