Vertical Forced Air Drying Oven

$0.00

Shipped From Abroad

Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-29
Brands:: Scitek

Description

Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature
Fluctuation(℃)
±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170

Quick Comparison

SettingsVertical Forced Air Drying Oven removeiSED Fully Automated ESR Analyzer removeApexBio HemoSmart Gold Hemoglobin Meter removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
NameVertical Forced Air Drying Oven removeiSED Fully Automated ESR Analyzer removeApexBio HemoSmart Gold Hemoglobin Meter removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeAGD Erma EL-120 ELectrolyte Analyzer remove
Image
SKUSF1033560130127-29SF1033560084-129SF1033560084-29SF1033560084-106SF1033560060-1SF1033560084-125
Rating
Price

$0.00

$0.00

$55.00

$8.20

$0.00

$1,320.00

Add to cart
DescriptionShipped From Abroad
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature Fluctuation(℃) ±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood. Feature
  • LCD Backlight
  • Small Blood Sample
  • Splash Proof
  • Strip Ejection
  • Hgb/Hct
  • Fast Result
Specification
  • Measurement Range: 0-24.0 g/dL
  • Power Supply: 3A battery X 2
  • Testing Time (seconds): 5 seconds
  • Sample Volume (μL): 1 μL
  • Memory Capabilities: 100 sets with date and time
  • Operating Temperature (°C): 10 °C~40 °C
 
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare