Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-29
Brands:: Scitek

Description

Applications of Forced Air Drying Oven:

Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.

Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature
Fluctuation(℃)
±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170

Reviews

There are no reviews yet.

Be the first to review “Vertical Forced Air Drying Oven”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVertical Forced Air Drying Oven removeAutomatic Pipette removeAvalun LabPad Device removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun 48 INR Microcuvette removeErma B-111 Bilirubin Meter remove
NameVertical Forced Air Drying Oven removeAutomatic Pipette removeAvalun LabPad Device removeDiscover 14 Panel Cup with Adulterants Per Pack removeAvalun 48 INR Microcuvette removeErma B-111 Bilirubin Meter remove
ImageAvalun Labpad machineDrug Test CupAvalun 48 INR Microcuvette
SKUSF1033560130127-29SF1033560084-130SF1033560084-65SF1033560084-28SF1033560084-74SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$715.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Applications of Forced Air Drying Oven:
Forced air drying oven has the characteristics of new design, advanced technology, precise temperature control, stable performance, easy maintenance, and easy operation. It is suitable for drying, baking, wax melting, and heat treatment in laboratories of industrial and mining enterprises, research institutes, pharmaceutical and health institutions, and other units.
Forced Air Drying Oven Features:
  1. The casing of the box is processed and formed from high-quality cold-rolled steel plates, and the surface is treated with electrostatic spraying technology, ensuring corrosion resistance and durability.
  2. The turbine centrifugal fan blades, with a unique combination of bottom blower and bottom heater, are equipped with vertical double air ducts for vertical hot air circulation, making the temperature distribution in the studio more uniform.
  3. The inner chamber is formed by high-quality mirror stainless steel processing, with four corners forming a semi circular transition surface treated with anti-corrosion technology. The spacing between partitions is adjustable, and the side plate of the air duct and the bottom heating cover have a quick disassembly structure, which is easy to clean.
  4. PID microcomputer intelligent temperature controller with timing and overtemperature alarm, precise temperature control, and convenient reading.
  5. Using a low noise blower.
  6. The box door with a new structure has good insulation effect, and is equipped with a double layer tempered glass large angle observation window in the middle. It is equipped with a lock type elastic adjustment door lock and a high-temperature resistant silicone sealing strip to ensure good sealing and prevent heat loss.
Forced Air Drying Oven Specifications:
Model FDO-30BI FDO-45B FDO-65B FDO-125B FDO-230B FDO-625B
Capacity(L) 30 45 65 125 230 625
Display LCD Display Screen
Temperature Range(℃) RT+10-300℃
Temperature Fluctuation(℃) ±1℃
Temperature Uniformity ±2.5%
Temperature Resolution(℃) 0.1℃
Time Setting 1~9999mins
Shelves 2pcs
Sensor Pt100
Power Supply AC220V±10%, 50/60Hz(Standard); AC110V, 60Hz(Optional) AC220V±10%, 50/60Hz
Power(W) 800 1200 1600 2300 3000 5000
Chamber Size (W×D×H)(mm) 310x310x310 350x350x350 400x360x450 500x450x550 600x500x750 660x760x1250
Size (W×D×H)(mm) 440x510x675 500x550x735 550x550x840 636x680x915 730x670x1220 895x925x1830
Shipping Size (W×D×H)(mm) 570x590x785 640x605x820 660x660x925 750x740x1020 920x820x1370 1020x1100x2020
N.W./G.W. (kg) 39/55 42/60 47/65 56/75 70/110 90/170
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare