Visible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-53
Brands:: Scitek

Description

Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer’s solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.

 

Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128×64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer, Bandwidth 2/4nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer, Bandwidth 2/4nm removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeiSED Fully Automated ESR Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack remove
NameVisible Spectrophotometer, Bandwidth 2/4nm removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeiSED Fully Automated ESR Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 5 Panel Cup with Adulterants Per Pack remove
ImageEppendorf Pipette Tip 200ul Per PackDrug Test Cup
SKUSF1033560130127-53SF1033560060-1SF1033560084-137SF1033560084-129SF1033560060-2SF1033560084-23
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From AbroadVisible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer's solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.
 
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128x64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare