Features of Wireless Capnometer CA80
  • Small in size, light in weight, only 60 grams.
  • Built-in Battery back up to 6 working hours.
  • Large font display and waveform interface.
  • Transport real-time data to monitor through USB.

 

Specifications of Wireless Capnometer CA80
Principle NDIR
Respiration 3 – 99 BPM; Accuracy:±1 breath
Agent Threshold Agent 0.3 vol%
Accuracy 0-40mmHg @ ±2% of reading,
41-70mmHg @ ±5% of reading,
71-100mmHg @ ±8% of reading,
101-150mmHg @ ±10% of reading.
Alarm Check adapter, No breath, Battery too low, ETCO2 too low, ETCO2 too high, INCO2 too high, RR too low, RR too high
Calibration No routine user calibration is required, the sensor automatically zeros when plugged in the adapter
Voltage & Power 5.0V DC 1A
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing

Quick Comparison

SettingsWireless Capnometer CA80 removeHersill Genesis Anaesthetic Machine removeAgary I.V. Cannula removeRender SD-M2000A Anesthetic Machine removeBistos BT-770-12.1" Touchscreen Patient Monitor removeOxygen Concentrator 3Ltr. remove
NameWireless Capnometer CA80 removeHersill Genesis Anaesthetic Machine removeAgary I.V. Cannula removeRender SD-M2000A Anesthetic Machine removeBistos BT-770-12.1" Touchscreen Patient Monitor removeOxygen Concentrator 3Ltr. remove
ImageHersill Genesis Anaesthetic MachineBistos BT-770-12.1" Touchscreen Patient Monitor
SKUSF1033560450-1SF1033560084-221SF1033560011-13SF1033560059-1SF1033560084-40
Price

$0.00

$0.00

$7.10

$1,870.00

$902.00

$273.00

Add to cart
DescriptionShipped From Abroad CA80 achieving the measuring of ETCO2, and Respiratory Rate in all Respiratory Conditions. Its small size, light in weight and low energy consumption, 6 hours working time, makes it flexible and convenient obviously. Suitable for CPR and emergency transportation.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Wireless Capnometer CA80
  • Small in size, light in weight, only 60 grams.
  • Built-in Battery back up to 6 working hours.
  • Large font display and waveform interface.
  • Transport real-time data to monitor through USB.
 
Specifications of Wireless Capnometer CA80
Principle NDIR
Respiration 3 – 99 BPM; Accuracy:±1 breath
Agent Threshold Agent 0.3 vol%
Accuracy 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading.
Alarm Check adapter, No breath, Battery too low, ETCO2 too low, ETCO2 too high, INCO2 too high, RR too low, RR too high
Calibration No routine user calibration is required, the sensor automatically zeros when plugged in the adapter
Voltage & Power 5.0V DC 1A
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH, non-condensing
Storage: -40º to 70ºC, <90% RH, non-condensing
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.   TECHNICAL SPECIFICATION OPERATING DATA
  • Weight - 105 kg
  • Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
  • Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
  • Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
  • Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
  • Battery autonomy - 90 min typically
  • Auxiliary power outlets - 4, with automatic protection
  • O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
  • Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
  • Protection class - Class I, gas analyser type BF defibrillation proof
  • Classification - Class II b
  • Storage - One front drawer with self-brake system and two back cabinets with door
  • Lighting - LED bar below the screen controlled from the touchscreen
  • Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
  • Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
  • Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
  • Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
  • 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
  • 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
  • 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
  • Autoclavable - 134 °C
  • Weight of breathing system - 9.8 kg
  • C02 absorber volume - 1.5 L
  • Leakage - < 150 mL/min (at 30 hPa)
  • Pressure limiting valve APL - 0 to 70 hPa
  • Pressure relief valve - 125 hPa
  • Vacuum safety valve - 0.3 hPa
  • resistance at 60L/min - 5.80 hPa
  • resistance at 60L/min - 2.90 hPa
  • resistance at 30L/min - 3.55 hPa
  • resistance at 30L/min - 0.89 hPa
  • Internal Compliance at 30 hPa - 15 mL
  VENTILATOR Operation / Ventilation Modes Volume controlled (VC) modes:
  • Volume Controlled Ventilation (VCV)
  • VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
  • VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
  • Pressure Controlled Ventilation (PCV)
  • PC Synchronized Intermittent Mandatory (PC-SIMV)
  • PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
  • Adaptive Pressure with Volume Guaranteed (APVG) *
  • APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
  • APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
  • (other trade names: PS, ASB, SPS, IPS)
  Non-mechanical Operation / Ventilation Modes
  • Manual ventilation through the CABS system (Auto/Manual software controlled)
  • Spontaneous ventilation either through the bellows (auto mode) or through the bag
  • (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
  • Tidal volume - 5 to 1500 mL
  • Inspiratory pressure - 0 to 68 hPa
  • Ventilation frequency ­- 3 to 120/min
  • Inspiratory time - 0.05 to 16.6s
  • l:E ratio - 5:1 to 1:8
  • Inspiratory pause - 0 to 60%
  • Inspiratory flow - max. 150 L/min
  • PEEP - 0 to 30 hPa
  • Flow trigger - 0.2 to 15 L/min
  • Pressure support - 5 to 50 hPa
  • Ramp time - 0.1 to 2 s
  • Maximum pressure - 0 to 68 hPa
  MONITORING
  • 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
  • Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
  • Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
  • Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
  • Configurable interface: bright/dark, multi-language.
  • Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
  • Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
 
Click Here To Download Catalogue
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
  • Compact design
  • save space in O.R or Laboratory Room
  • High quality & Durability design
  • Easy operation & easy maintenance
  • New integrated respiratory circuit available with own patent
  • LED Ventilator inside & One standard ZF-1000 precise vaporizer
  • Optional: Two precise ZF-1000 vaporizers
 
Click Here To Download Catalogue
   
 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
en English
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare