YCB-7000 Patient/Blanket Warmer

Ask for Price$0.00

Shipped From Abroad

For patients with stable, easy transfer, to prevent damage from the patients to bed when dragging and pulling caused, especially to meet patients with head and neck, spine surgery, joint replacement surgery patients, high safety requirements to intubation surgery patients, can not easily touch the patient to bed needs

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356004

Description

Product Function:

For patients with stable, easy transfer, to prevent damage from the patients to bed when dragging and pulling caused, especially to meet patients with head and neck, spine surgery, joint replacement surgery patients, high safety requirements to intubation surgery patients, can not easily touch the patient to bed needs

 

The utility model reduces the pain and discomfort of the patient when the bed is moved, and greatly reduces the pain of the patient

 

The labor intensity of the nursing staff is reduced, the work efficiency is improved, and the medical dispute caused by the improper transfer of the patient is avoided

Product Principle:

Move the slide pad with the one-time pad patient transfer, low pressure air filling pump sliding pad, were suspended so that uniform airflow in air below the spray formed on the

sliding pad and the air layer between the bed body, play the role of reducing friction, realizes the transfer without laborious to the patient

Product Features:

save effort and save time, Safe and efficient Transfer patient

relieve pain Avoid the two damage caused by metastasis

High bearing strength, load of 150kg

Advantages of Medical Warming System

  1. Fully computer-controlled, highly intelligent, temperature control is reliable and sensible.
  2. 5-inch colorful LCD display.
  3. Front self-locked tight air pipe connector, convenient, flexible and well-sealed.
  4. A rotating button, simple and quick. All operations can be adjusted only by this single button.
  5. Four-gear temperature settings and two optional wind speeds.
  6. Automatic temperature control, automatic timing, heating up quickly.
  7. Blanket is disposable, without crossed infection, tidy and safe.
  8. Alarming and outage protecting function when temperature is higher or lower than settings.
  9. Metal appearance passed electromagnetic compatibility detection with strong anti-interference.
  10. Alarming and outage protecting function when temperature is higher or lower than settings.
  11. Safe and reliable, can be used for a long time continuously.
  12. Equipped with various sizes of blanket meeting different requirements of patients warming system for keeping patient warm includes warmer blanket

Technical Parameters of Host Machine:

  • Environmental temperature: 10℃~40℃
  • Relative humidity: ≤80%
  • Power voltage: 220V±22V 50Hz±1H
  • Atmospheric pressure: 860hpa~1060hp
  • Temperature of blanket: 4 gears temperature settings: Room temperature, 32 ℃, 38 ℃ and 43 ℃, Precision: ±1.5℃
  • High temperature alarming: Alarm and stop working when temperature is 3 ℃ higher than the settings.
  • Low temperature alarming: alarm when temperature is 3 ℃ lower than settings.
  • Accumulative timing: Maximum 255 h, timing precision ≤±1min.
  • Wind speed: high-speed 26±1 km/h, low-speed 23±1 km/h.
  • Noise: ≤49 db
  • Total power:≤350 w
  • Continuous working.
  • Size of blanket: 192cm W×100cm L, Error±5cm
  • Blanket breaks: Any seal of blanket shall not be broken before using

Accuracy of temperature: Reach following temperature in 7 min, Low-gear: 32℃±1.5℃Middle-gear: 38℃±1.5℃, High-gear 43℃±1.5℃.

Reviews

There are no reviews yet.

Be the first to review “YCB-7000 Patient/Blanket Warmer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsYCB-7000 Patient/Blanket Warmer removeHawksley 1400 Haematocrit Centrifuge removeSyringe Needle Destroyer removeAB Diagnostic HEV IgG Elisa Kit removeAB Diagnostic Progesterone Elisa Kit removeOptika B-150D-BRPL Digital Binocular Microscope remove
NameYCB-7000 Patient/Blanket Warmer removeHawksley 1400 Haematocrit Centrifuge removeSyringe Needle Destroyer removeAB Diagnostic HEV IgG Elisa Kit removeAB Diagnostic Progesterone Elisa Kit removeOptika B-150D-BRPL Digital Binocular Microscope remove
ImageHBs Ag Elisa KitProgesterone Elisa KitOptika B-150D-BRPL Digital Binocular Microscope
SKUSF103356004SF1033560084-118SF1033560084-206SF1033560084-212SF1033560084-214SF1033560098-2
Rating
Price

Ask for Price$0.00

$690.00

$157.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
For patients with stable, easy transfer, to prevent damage from the patients to bed when dragging and pulling caused, especially to meet patients with head and neck, spine surgery, joint replacement surgery patients, high safety requirements to intubation surgery patients, can not easily touch the patient to bed needs
Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia HEV IgG is an enzyme immunoassay for the qualitative detection of IgG antibodies to hepatitis E virus (HEV) in human serum or plasma. The assay is intended for screening for potentially infectious samples.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia Progesterone enzyme immunoassay for the quantitative determination of progesterone concentration in human serum.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad Cordless digital binocular microscope ideal for students and primary schools, with four PLAN achromatic lenses (1000x), FN 18 high eyepoint eyepieces, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 1 W X-LED1 illumination.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentProduct Function: For patients with stable, easy transfer, to prevent damage from the patients to bed when dragging and pulling caused, especially to meet patients with head and neck, spine surgery, joint replacement surgery patients, high safety requirements to intubation surgery patients, can not easily touch the patient to bed needs   The utility model reduces the pain and discomfort of the patient when the bed is moved, and greatly reduces the pain of the patient   The labor intensity of the nursing staff is reduced, the work efficiency is improved, and the medical dispute caused by the improper transfer of the patient is avoided Product Principle: Move the slide pad with the one-time pad patient transfer, low pressure air filling pump sliding pad, were suspended so that uniform airflow in air below the spray formed on the sliding pad and the air layer between the bed body, play the role of reducing friction, realizes the transfer without laborious to the patient Product Features: save effort and save time, Safe and efficient Transfer patient relieve pain Avoid the two damage caused by metastasis High bearing strength, load of 150kg Advantages of Medical Warming System
  1. Fully computer-controlled, highly intelligent, temperature control is reliable and sensible.
  2. 5-inch colorful LCD display.
  3. Front self-locked tight air pipe connector, convenient, flexible and well-sealed.
  4. A rotating button, simple and quick. All operations can be adjusted only by this single button.
  5. Four-gear temperature settings and two optional wind speeds.
  6. Automatic temperature control, automatic timing, heating up quickly.
  7. Blanket is disposable, without crossed infection, tidy and safe.
  8. Alarming and outage protecting function when temperature is higher or lower than settings.
  9. Metal appearance passed electromagnetic compatibility detection with strong anti-interference.
  10. Alarming and outage protecting function when temperature is higher or lower than settings.
  11. Safe and reliable, can be used for a long time continuously.
  12. Equipped with various sizes of blanket meeting different requirements of patients warming system for keeping patient warm includes warmer blanket
Technical Parameters of Host Machine:
  • Environmental temperature: 10℃~40℃
  • Relative humidity: ≤80%
  • Power voltage: 220V±22V 50Hz±1H
  • Atmospheric pressure: 860hpa~1060hp
  • Temperature of blanket: 4 gears temperature settings: Room temperature, 32 ℃, 38 ℃ and 43 ℃, Precision: ±1.5℃
  • High temperature alarming: Alarm and stop working when temperature is 3 ℃ higher than the settings.
  • Low temperature alarming: alarm when temperature is 3 ℃ lower than settings.
  • Accumulative timing: Maximum 255 h, timing precision ≤±1min.
  • Wind speed: high-speed 26±1 km/h, low-speed 23±1 km/h.
  • Noise: ≤49 db
  • Total power:≤350 w
  • Continuous working.
  • Size of blanket: 192cm W×100cm L, Error±5cm
  • Blanket breaks: Any seal of blanket shall not be broken before using
Accuracy of temperature: Reach following temperature in 7 min, Low-gear: 32℃±1.5℃Middle-gear: 38℃±1.5℃, High-gear 43℃±1.5℃.
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Abia HEV IgG is an enzyme immunoassay for the qualitative detection of IgG antibodies to hepatitis E virus (HEV) in human serum or plasma. The assay is intended for screening for potentially infectious samples. Abia HEV IgG DK.029.01.3:
HEV Ag coated plate: 1 plate Sample diluent: 12 ml
Conjugate (concentrated 21-fold): 1 ml
Conjugate diluent: 20 ml
HEV Ab positive control (inactivated):1.2 ml
Negative control (inactivated): 2.5 ml
Washing solution (concentrated 25-fold): 50 ml
TMB (concentrated 21-fold): 2.5 ml
Substrate buffer: 25 ml
Stopping reagent 0.75M H2SO4: 25 ml
Protective film: 2
Plastic dish: 2
Plastic zip-lock bag: 1
Abia HEV IgG DK.029.05.3:
HEV Ag coated plate: 5 plates Sample diluent: 50 ml
Conjugate (concentrated 21-fold): 4 ml
Conjugate diluent: 75 ml
HEV Ab positive control (inactivated): 2.4 ml
Negative control (inactivated): 5 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 21-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.75M H2SO4: 90 ml
Protective film: 10
Plastic dish: 0
Plastic zip-lock bag: 5
Abia Progesterone enzyme immunoassay for the quantitative determination of progesterone concentration in human serum. Abia Progesterone (DK.039.01.3): 
Progesterone Ab coated plate: 1 Conjugate: 12 ml
Calibrator 0: 0.5 ml
Calibrator 1: 0.5 ml
Calibrator 2: 0.5 ml
Calibrator 3: 0.5 ml
Calibrator 4: 0.5 ml
Calibrator 5: 0.5 ml
Control serum: 0.5 ml
Washing solution (concentrated 25-fold): 50 ml
TMB/substrate solution: 12 ml
Stopping reagent 0.2M H2SO4: 25 ml
Protective film: 1
Plastic dish: 2
Plastic zip-lock bag: 1
Cordless digital binocular microscope ideal for students and primary schools, with four PLAN achromatic lenses (1000x), FN 18 high eyepoint eyepieces, finite optical system, coaxial focusing, mechanical stage, Abbe condenser and powerful, uniform, white color temperature 1 W X-LED1 illumination. Slim and easy to carry, it is equipped with all the main controls to start learning how to use an advanced microscope and with long lasting LED illumination to provide over 20 years of use. The exclusive Li-Ion battery ensures unparalleled duration and fast recharge. Features:
  • Observation mode: Brightfield.
  • Head: Binocular, 30° inclined; 360° rotating. With integrated 3.1 MP camera.
  • Eyepieces: WF10x/18 mm, secured by screw.
  • Nosepiece: Quadruple ball bearings revolving nosepiece.
  • Objectives: – N-PLAN 4x/0.10 , with anti-fungus treatment – N-PLAN 10x/0.25 , with anti-fungus treatment – N-PLAN 40x/0.65 , with anti-fungus treatment – N-PLAN 100x/1.25 (Oil/Water) , with anti-fungus treatment
  • Specimen stage: Mechanical stage, 125x116mm, 70×30 mm X-Y movement range. Vernier scale on the two axes, accuracy: 0.1mm.
  • Focusing: Coaxial coarse and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Adjustable tension of coarse focusing knob.
  • Condenser: Abbe N.A. 1.25, pre-centered, focusable, with iris diaphragm.
  • Illumination: X-LED1 with white 1 W LED and light intensity control.
  • Color temperature: 6,300 K. Li-Ion battery for long lasting operation. Multi-plug 100-240Vac/5Vdc external power supply.
  Technical Specifications:
Observation Method - Transmitted Light Brightfield Yes
  Simple polarized light As optional
Main Body Type Upright
  Construction material Aluminum die-cast
Head Head Binocular (Siedentopf)
  Inclination 30°
  360° rotating Yes
  Interpupillary distance (mm) 48-75
  Dioptric adjustement On left tube
  Fixing screw for eyepieces Yes
  Tube inner diameter (mm) 23
Eyepieces Field number (mm) 18
  Magnification 10x
  High eyepoint (for glass wearers) Yes
  Pointer As optional
  Micrometric scale As optional
  Diameter of micrometer glass (mm) 20
Nosepiece Positions Quadruple
  Bi-directional Yes
  Rotation on ball bearings Yes
  Objective thread RMS
Objectives Optical system 160
  Anti-fungus treatment Yes
  Parfocal distance (mm) 45
  Standard magnifications 40x-1000x
  Type N-PLAN
  Objectives included 4x/0.10, W.D. 15.2 mm
  10x/0.25, W.D. 5.5 mm
  40x/0.65, W.D. 0.45 mm
  100x/1.25 (Oil/Water), W.D. 0.13 mm
Stage Type Double layer
  Dimensions (mm) 125x116
  Moving mechanism Rack and pinion
  Moving range (mm) 70x30
  Material Anti-scratch painting
  Specimen holder Yes
  Slide number 1
  X-Y Vernier scale Yes
  Vernier scale accuracy (mm) 0.1
Condenser - Single Position Type Abbe
  Numerical aperture (N.A.) 1.25
  Diaphragms Iris
  Centrable Pre-centered
  Focusable By rotation
Focusing System Type Coaxial coarse & fine
  Coarse total travel (mm) 16
  Fine total travel (per single rotation) (mm) 0.4
  Fine graduations 100
  Fine resolution (µm) 4
  Upper stop to prevent contact Yes
  Adjustable tension Yes
Transmitted Illumination Type X-LED
  X-LED type X-LED1
  Light source power (W) 1
  Brightness control Manual
  Lifetime (hours) > 65,000
  Temperature (K) 6,300
  Max. required power (W) 1.5
Power Supply for Transmitted Illumination Type External
  Microscope connector Jack, 2.1 mm
  Power plug type Multi-plug (EU, UK, US)
  Input voltage 100/240 Vac, 50/60 Hz
  Output voltage 5 Vdc 500 mA
  LED indicator Yes
  Rechargeable batteries Yes
  Battery type Li-ion (battery pack)
  Working time of batteries (hours) 15
  Charging time of batteries (hours) 6
Accessories Included Dust cover Yes
  Immersion oil (10ml) Yes
  Tension adjustment tool Yes
  User Manual Digital version (downloadable)
  USB cable (m) 1.8
  CD-ROM Yes
Additional Information Mirror for transmitted light (as optional)
Product Dimensions Height (mm) 365
  Width (mm) 170
  Depth (mm) 320
Product Weight (kg) 4
Digital Head Resolution (MP) 3.2
Sensor type CMOS
Sensor size 1/2.5"
Sensor aspect ratio 4/3
Full image size 2048x1536
Pixel size (µm) 2.2x2.2
Frame rate 4 fps (2048x1536), 8 fps (1280x1024), 30 fps (640x480)
S/N ratio (dB) 40
Dynamic range (dB) 66.5
Sensitivity (V/lux*s @550nm) 0.53
Exposure time (s) 15 - 1/1500
USB type 2.0
System requirements Win 7 / Win 8 / Win 10 (32/64 bit)
Software OPTIKA PROView
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare