AB Diagnostic abia Treponema Ab Elisa Kit
$0.00
In Stock
abia Treponema Ab is an enzyme immunoassay for the qualitative detection of antibodies to Treponema pallidum in human serum or plasma. The assay is intended for screening for potentially infectious samples to prevent their use as donor materials.
Description
abia Treponema Ab is an enzyme immunoassay for the qualitative detection of antibodies to Treponema pallidum in human serum or plasma. The assay is intended for screening for potentially infectious samples to prevent their use as donor materials.
Kit Contents;
T. pallidum Ag coated plate 1 plate
Conjugate diluent 12 ml
Positive control (inactivated) 2.5 ml
Washing solution (concentrated 25-fold) 50 ml
Substrate buffer 25 ml
Protective film 2
Zip-lock plastic bag 1
Conjugate (concentrated 11-fold) 1.2 ml
Sample diluent 14 ml
Negative control (inactivated) 2.5 ml
TMB (concentrated 11-fold) 2.5 ml
Stopping reagent 0.2M H2SO4 25 ml
Plastic dish 2
Quick Comparison
AB Diagnostic abia Treponema Ab Elisa Kit remove | Hawksley 1400 Haematocrit Centrifuge remove | Erma B-111 Bilirubin Meter remove | 8 Bucket Centrifuge remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Eppendorf Minispin Centrifuge remove | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | AB Diagnostic abia Treponema Ab Elisa Kit remove | Hawksley 1400 Haematocrit Centrifuge remove | Erma B-111 Bilirubin Meter remove | 8 Bucket Centrifuge remove | Discover 14 Panel Cup with Adulterants Per Pack remove | Eppendorf Minispin Centrifuge remove | ||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||
SKU | SF1033560061 | SF1033560084-118 | SF1033560084-6 | SF1033560084-114 | SF1033560084-28 | SF1033560084-116 | ||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||
Price |
| $690.00 | $715.00 | $72.50 |
|
| ||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||
Description | In Stock
abia Treponema Ab is an enzyme immunoassay for the qualitative detection of antibodies to Treponema pallidum in human serum or plasma. The assay is intended for screening for potentially infectious samples to prevent their use as donor materials.
| In stock
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
| In stock
| ||||||||||||||||||||||||
Content | abia Treponema Ab is an enzyme immunoassay for the qualitative detection of antibodies to Treponema pallidum in human serum or plasma. The assay is intended for screening for potentially infectious samples to prevent their use as donor materials.
Kit Contents;
T. pallidum Ag coated plate 1 plate
Conjugate diluent 12 ml
Positive control (inactivated) 2.5 ml
Washing solution (concentrated 25-fold) 50 ml
Substrate buffer 25 ml
Protective film 2
Zip-lock plastic bag 1
Conjugate (concentrated 11-fold) 1.2 ml
Sample diluent 14 ml
Negative control (inactivated) 2.5 ml
TMB (concentrated 11-fold) 2.5 ml
Stopping reagent 0.2M H2SO4 25 ml
Plastic dish 2
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue |
All-in-One Design
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Click Here To Download Catalogue | ||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.