ALCOHOL 70% UNTINTED HOSPITAL GRADE SURFACE DISINFECTANT

Ask for Price$0.00

Shipped From Abroad

Available in 500mL plastic flip top bottle in packs of 24 per carton.

Alcohol 70% is a bactericidal hospital grade disinfectant suitable for general purpose disinfection of hospital equipment and surfaces.  Do not use on Therapeutic Devices.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013099-9
Brands:: PharmAust

Description

Product Description

Alcohol 70% is a bactericidal hospital grade disinfectant suitable for general purpose disinfection of hospital equipment and surfaces.  Do not use on Therapeutic Devices.

Not to be swallowed. Highly flammable, do not use near a naked flame.

Keep out of reach of children. Avoid contact with eyes and mouth.

First Aid

For advice, contact a Poisons Information Centre (Phone Australia 131126) or a Doctor Give plenty of water to drink. If in eyes hold eyes open and flood with water for at least 15 minutes and see a doctor.

Alcohol 70% is used where disinfecting surface areas is a priority. Apply as required undiluted. Allow to self-dry. DO NOT mix with other detergents or chemicals. Do not return used solution to the bottle, discard unused portion.

Store below 25°C.

Warning: Flammable Liquid. 

Reviews

There are no reviews yet.

Be the first to review “ALCOHOL 70% UNTINTED HOSPITAL GRADE SURFACE DISINFECTANT”

Your email address will not be published. Required fields are marked *

Quick Comparison

ALCOHOL 70% UNTINTED HOSPITAL GRADE SURFACE DISINFECTANT removeMaico MB11 Brainstem Evoked Response Audiometer removeMaico TouchTymp MI36 Tympanometry remove2-Function Manual Hospital Bed removeMale Urinal removeSmith Medical Nasopharyngeal Airway (Portex) remove
NameALCOHOL 70% UNTINTED HOSPITAL GRADE SURFACE DISINFECTANT removeMaico MB11 Brainstem Evoked Response Audiometer removeMaico TouchTymp MI36 Tympanometry remove2-Function Manual Hospital Bed removeMale Urinal removeSmith Medical Nasopharyngeal Airway (Portex) remove
ImageMaico MB11 Brainstem Evoked Response AudiometerMaico TouchTymp MI36 Tympanometry and Amp
SKUSF103356013099-9SF1033560063-9SF1033560063-10SF1033560084-52SF1033560084-86SF1033560084-36
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

$215.00

$6.40

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Available in 500mL plastic flip top bottle in packs of 24 per carton. Alcohol 70% is a bactericidal hospital grade disinfectant suitable for general purpose disinfection of hospital equipment and surfaces.  Do not use on Therapeutic Devices.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The unique patented Auditory Brainstem Response system offers a fast automated ABR hearing test for newborns without the use of adhesive disposables. To grant babies the comfort of disposable-free ABR screening, our BERAphone® comes with integrated electrodes and a speaker with ear cushion in a single unit. If the BERAphone® detects and verifies a response at 35 dB nHL, the test result is PASS. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Smith Medical Nasopharyngeal Airway (Portex): Recommended for use in the semi-conscious or unconscious patient with an intact gag reflex. Not easily dislodged during transport and better tolerated than an Oropharyngeal Airway. Designed to be inserted into the nasal passageway to secure an open airway. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description
Alcohol 70% is a bactericidal hospital grade disinfectant suitable for general purpose disinfection of hospital equipment and surfaces.  Do not use on Therapeutic Devices. Not to be swallowed. Highly flammable, do not use near a naked flame. Keep out of reach of children. Avoid contact with eyes and mouth. First Aid For advice, contact a Poisons Information Centre (Phone Australia 131126) or a Doctor Give plenty of water to drink. If in eyes hold eyes open and flood with water for at least 15 minutes and see a doctor. Alcohol 70% is used where disinfecting surface areas is a priority. Apply as required undiluted. Allow to self-dry. DO NOT mix with other detergents or chemicals. Do not return used solution to the bottle, discard unused portion. Store below 25°C. Warning: Flammable Liquid. 
The MB 11 Brainstem Evoked Response Audiometer (B.E.R.A) stands for innovation in Newborn Hearing Screening — the unique, patented Auditory Brainstem Response system offers a fast automated ABR hearing test for newborns without the use of adhesive disposables. To grant babies the comfort of disposable-free ABR screening, our BERAphone® comes with integrated electrodes and a speaker with ear cushion in a single unit. If the BERAphone® detects and verifies a response at 35 dB nHL, the test result is PASS. FEATURES AT A GLANCE
  • Fast and automated ABR screening with reliable results in seconds
  • Unique BERAphone® with integrated electrodes saves costs for disposables
  • Automatic impedance check indicates test conditions
  • CE-Chirp® Stimulus
  • Stimulus level of 35 dB nHL
ABR System with Patented CE-Chirp® for Fast Results
  • Our MB 11 BERAphone® is equipped with a unique CE-Chirp® which stimulates all regions of the cochlea at the same time to generate much higher responses and faster results than a standard click. This leads to highly accurate results for Auditory Brainstem Response Tests under normal nursing conditions.
Easy for You, Comfortable for the Baby The MB 11 BERAphone® makes ABR hearing tests for newborns easier for both sides:
  • When the newborn is asleep or calm, apply the electrode gel at the three electrode sites on the baby’s head.
  • Place a drop of electrode gel on the integrated electrodes.
  • Position the MB 11 BERAphone®, surrounding the baby's ear with the earphone and resting the electrodes on the prepared sites.
  • No adhesive disposables are needed. You will save costs and the babies will not experience any pulling or pain while being tested.
Baby-friendly and cost-efficient, that is the key for effective ABR testing. User-Friendly PC Software
  • Keeping track of your test and patient data of ABR tests is easy with the MB 11 BERAphone®. Transfer your data to a PC via USB connection and make use of the intuitive PC software that comes with the MB 11 BERAphone®. The simple user interface enhances the ease of training and allows even first-time users to navigate easily through the software. The “Traffic Light” display for electrode contact and test quality provides easy to understand feedback to screeners. If you want to use HiTrack or Oz, there are export functions ready for you to use. The MB 11 BERAphone® makes Newborn Hearing Screening and ABR hearing tests easy!
TECHNICAL SPECIFICATION MB 11 BERAphone®
  • Dimensions / Weight - 120 mm x 93 mm x 30 mm / 142 g
  • Display - Test result (Pass, Refer or Abort), test diagram with line towards PASS, signal quality or EEG, traffc light for impedance test
  • Languages - English, German, Spanish, French, Italian, Dutch, Turkish, Hungarian, Russian, Chinese, Japanese
  • PC interface – USB
  • Power supply - USB-Port 5V DC max. 400 mA
BERAphone®
  • One Channel - 3 reusable stainless-steel electrodes
  • Gain - 69.6 dB
  • CMR Ratio - >110 dB at 80 Hz
  • Transducer - Integrated dynamic speaker (8 Ω)
  • Dimensions / Weight - 160 mm x 87 mm x 60 mm / 285g
ABR
  • Stimuli - CE-Chirp®
  • Stimulus rate - ~90 /s
  • Stimulus level - 35 dB nHL
  • Test mode - monaural
  • Impedance test - Automatic pre-test
  • Test duration - 16 s to 180 s
  • Artifact rejection level - 100 µV
Computer Requirements
  • Type - 2 GHz or more
  • RAM - Minimum 1 GB
  • Hard Disk - Minimum 10 GB free disk space
  • Interface - USB 1.1, 2.0 or 3.0
  • Display - Min. resolution 1280 x 1024 or higher
  • Graphic card - Direct X9 with WDDM 1.0 or higher
  • Operating System - Windows7 Professional, Windows8 Pro, Windows10 Pro
 
Click Here To Download Catalogue
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
Product Size:2125*970*540mm Packing size: 205*96*26cm/2pcs Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5° Standard Accessories: 4pcs 5” standard castor two with brake, 1 pair aluminum side rail, 2pcs ABS head and foot board, 4pcs urine hooks, 2pcs cranks system
Smith Medical Nasopharyngeal Airway (Portex): Recommended for use in the semi-conscious or unconscious patient with an intact gag reflex. Not easily dislodged during transport and better tolerated than an Oropharyngeal Airway. Designed to be inserted into the nasal passageway to secure an open airway. Features:
  • Robertazzi style
  • Flared end prevents the device from becoming lost inside the patients nose
  • Soft no damage to nasal passage
  • Flexible resists collapse or kinking
  • Latex-free
  • 15mm fitting
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare