Anaesthesia Machine Model 40
$0.00
Shipped From Abroad
The Anesthesia Workstation Model 30 is a high-performance anesthesia delivery system designed for precision, safety, and efficiency in medical environments. It features an 8-inch color TFT LCD screen, dual-end pressure flow sensor, and advanced gas monitoring capabilities. The unit supports multiple ventilation modes (IPPV, SIMV, PSV, SIPPV, etc.), ensuring adaptability for adult and pediatric patients. Equipped with a CO₂ absorber, precise vaporizers, and a gas interlocking safety system, it enhances patient safety and workflow efficiency. Additional features include backup battery support, power failure alarms, and an optional yoke system for O₂ and N₂O cylinders.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
-
Built-in 8” color anesthesia ventilator
-
Traditional CO₂ absorber (autoclavable, Patent)
-
Dual high-end precise vaporizers (Volume > 280ml)
-
Dual gas sources system (O₂/N₂O)
-
Continuous FiO₂ monitoring & bain circuit interface
-
Electronic tidal volume (Innovation)
-
Battery backup for all systems over 60 mins
-
Optional: Backup Yoke system (O₂, N₂O)
-
Optional: Anesthesia gas scavenging system
-
Optional: Anesthesia gas modular patient monitor
-
ABS Structure
-
Large pressure gauges for easy reading
-
CO₂ absorber with easy change-over system
-
Optional: Yoke system for backup 1xO₂, 1xN₂O A-Type cylinder
Safety Features
-
Gas interlocking system with hypoxy guard
-
Oxygen exhaust alarm
-
Blow-off valve in top circuit
Technical Specification
Anaesthesia Main Unit
-
High-resolution 8” color TFT LCD screen
-
Dual-end pressure flow sensor for monitoring:
-
Tidal Volume
-
Respiratory frequency
-
Airway pressure
-
Pressure-time wave
-
Flow-time wave (two-way)
-
High and Low Pressure limitations
-
Apnea
-
Oxygen concentration (Auto/Manual)
-
-
Respiration loop function: Close, Semi-close, Semi-open
-
Application: Adult, Pediatric
-
Low gas alarming: Alerts if gas supply lasts under 7 seconds
-
High pressure limitation: Safety shutoff for overpressure
-
Low pressure protection: Auto stop for N₂O if O₂ pressure < 0.1 MPa
-
Power failure alarming & extendable function
-
O₂ flush: 25 ~ 75L/min
-
Gas pressure:
-
O₂: 0.3 ~ 0.5 MPa
-
N₂O: 0.3 ~ 0.5 MPa
-
-
Power supply: 220V±10%, 50Hz±1%; Backup USB Battery
-
Optional: Yoke system for backup O₂, N₂O cylinders
Flow Meter
-
O₂, N₂O – Four tubes (0.05 ~ 1 L/min, 1 ~ 10 L/min)
-
O₂/N₂O inter-lock system to keep O₂ concentration ≥ 25%
Anaesthesia Ventilator
-
Adult, Pediatric bellows 1 set each
-
Pneumatic driven electric control
-
Monitor parameters:
-
Tidal Volume
-
Respiratory frequency
-
I:E ratio
-
M.V.
-
FiO₂
-
Apnea
-
Peak airway pressure
-
Airway pressure waves
-
-
Working Modes: Manual, Auto (IPPV, SIGH, SIMV, SIPPV, Demo, optional PCV, PSV)
-
Tidal Volume: 50 ~ 1500 mL
-
Respiratory Frequency: 4 ~ 99 bpm
-
I:E Ratio: 1.0:5 ~ 1:8 (Adjustable)
-
Trigger Pressure: -2 ~ 0 kPa
-
High pressure limitation: 2 ~ 6 kPa
-
Low pressure limitation: 0 ~ 2 kPa
Respiratory Circuit
-
Compact CO₂ absorber (Autoclavable)
Vaporizer
-
High-end precise vaporizers (Halothane, Isoflurane, Sevoflurane)
-
Adjustable ranges:
-
Halothane/Isoflurane: 0.5 ~ 5% VOL
-
Sevoflurane: 0.5 ~ 8% VOL
-
-
Automatic compensation function (flow, pressure, temperature)
-
Self-lock function & inter-lock function
-
Volume: >280 mL
Quick Comparison
Settings | Anaesthesia Machine Model 40 remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Hersill Genesis Anaesthetic Machine remove | Render SD-M2000B Anesthetic Machine remove | Siare Morpheus E Anaesthetic Machine remove | Lab/Ward Coat remove | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Anaesthesia Machine Model 40 remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Hersill Genesis Anaesthetic Machine remove | Render SD-M2000B Anesthetic Machine remove | Siare Morpheus E Anaesthetic Machine remove | Lab/Ward Coat remove | ||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||
SKU | SF1033560084-18 | SF1033560450-1 | SF1033560011-10 | SF1033560101-1 | SF1033560084-222 | |||||||||||
Rating | ||||||||||||||||
Price |
|
|
| $4,840.00 |
| $11.00 | ||||||||||
Stock | ||||||||||||||||
Availability | ||||||||||||||||
Add to cart | ||||||||||||||||
Description | Shipped From Abroad
The Anesthesia Workstation Model 30 is a high-performance anesthesia delivery system designed for precision, safety, and efficiency in medical environments. It features an 8-inch color TFT LCD screen, dual-end pressure flow sensor, and advanced gas monitoring capabilities. The unit supports multiple ventilation modes (IPPV, SIMV, PSV, SIPPV, etc.), ensuring adaptability for adult and pediatric patients. Equipped with a CO₂ absorber, precise vaporizers, and a gas interlocking safety system, it enhances patient safety and workflow efficiency. Additional features include backup battery support, power failure alarms, and an optional yoke system for O₂ and N₂O cylinders.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
| Shipped from Abroad The MORPHEUS E is an anaesthesia machine with electronic flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||
Content | Features
Safety Features
Technical SpecificationAnaesthesia Main Unit
Flow Meter
Anaesthesia Ventilator
Respiratory Circuit
Vaporizer
| This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times. | The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue |
Click Here To Download Catalogue | The MORPHEUS E is an anaesthesia machine with Electronic Flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS E is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
Click Here To Download Catalogue |
| ||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||
Additional information |