Anaesthesia Machine Model 50
$0.00
Shipped From Abroad
The Anesthesia Workstation Model 30 is an advanced medical device featuring precise ventilation control, integrated vaporizers, safety alarms, and a user-friendly interface for efficient anesthesia delivery in surgical environments.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
- Contains Output interface for Anesthesia information management system.
- Complete with backup battery for working more than 120 minutes.
-
Built-in 10.4” color anesthesia ventilator
-
Traditional CO₂ absorber (autoclavable, Patent)
-
Dual high-end precise vaporizers (Volume > 280ml)
-
Three gas sources system (O₂/N₂O/Air)
-
Continuous FiO₂ monitoring & bain circuit interface
-
Electronic tidal volume (Innovation)
-
Battery backup for all systems over 60 mins
-
Optional: Backup Yoke system (O₂, N₂O)
-
Optional: Anesthesia gas scavenging system
-
Optional: Anesthesia gas modular patient monitor
-
Structure made of ABS
-
Large pressure gauges for easy reading
-
CO₂ absorber with easy changeover system
-
Optional: Yoke system for backup 1×O₂, 1×N₂O A-Type cylinder
Safety Features
-
Gases interlocking system with hypoxy guard
-
Oxygen exhaust alarm
-
Blow-off valve in top circuit
Technical Specification
Anaesthesia main unit
-
High resolution 10.4″ color TFT LCD screen
-
Dual-end pressure flow sensor, the unit can monitor Tidal Volume, Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way), High Pressure limitation, Low Pressure limitation, Apnea, Oxygen concentration under both two operating modes (Auto, Manual)
-
Respiration loop function
-
Close, semi-close, semi-open
-
Application: Adult, Pediatric
-
Low gas alarming: It gives an alarm if it lasts more than 7 seconds.
-
High pressure Limitation: Whenever airway pressure exceeds the pre-set High pressure, the ventilator offers automatic protection to ensure patient safety.
-
Low pressure protection: Once O₂ pressure is less than 0.1MPa, N₂O gas supply stops automatically.
-
Power failure alarming, power extendable function
-
O₂ flush: 25 ~ 75L/min
-
Gas Pressure:
-
O₂: 0.3 ~ 0.5MPa
-
N₂O: 0.3 ~ 0.5MPa
-
AIR: 0.3 ~ 0.5MPa
-
-
Power: 220V±10%, 50Hz±1%; Backup USP Battery.
-
Optional: Yoke system for backup O₂, N₂O cylinders
Flow meter
-
O₂, N₂O, AIR – six tubes (0.05 ~ 1 L/min, 1 ~ 10L/min)
-
O₂/N₂O inter-lock system, to keep O₂ concentration no less than 25%
Anaesthesia Ventilator
-
Adult, Pediatric bellows 1 set each
-
Pneumatic-driven electric control
-
Monitor Parameters: Tidal volume, Respiratory frequency, I:E rate, M.V., FiO₂, Apnea, Peak airway pressure, airway pressure waves (P-T, F-T) etc.
-
Working mode: Manual, Auto (IPPV, SIMV, A/C, SIGH, PCV, PSV, Demo.)
-
Tidal volume: 50 ~ 1500 mL
-
Respiratory frequency: 4 ~ 99 bpm
-
I:E Ratio: 1.0:5 ~ 1:8 (adjustable)
-
Synchronizer trigger Pressure: -2 ~ 0 kPa
-
High pressure limitation: 2 ~ 6 kPa
-
Low pressure limitation: 0 ~ 2 kPa
Respiratory Circuit
-
Consolidated compact CO₂ absorber (autoclavable).
Vaporizer
-
High-end precise vaporizer (Halothane, Isoflurane, Sevoflurane)
-
Halothane/Isoflurane adjustable range: 0.5 ~ 5% VOL
-
Sevoflurane adjustable range: 0.5 ~ 8% VOL
-
Automatic compensation function – flow, pressure, temperature
-
Self-lock function & inter-lock function
-
Volume: >280 ml
Quick Comparison
Settings | Anaesthesia Machine Model 50 remove | MediPlus Bain Circuit (Adult) remove | CWS 5000- Patient Warming Machine remove | Hersill Genesis Anaesthetic Machine remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Oxygen Concentrator 3Ltr. remove | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Anaesthesia Machine Model 50 remove | MediPlus Bain Circuit (Adult) remove | CWS 5000- Patient Warming Machine remove | Hersill Genesis Anaesthetic Machine remove | Elastomeric Pump (Disposable Infusion Pump) with PCA remove | Oxygen Concentrator 3Ltr. remove | ||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||
SKU | SF1033560084-21 | SF103356013087-1 | SF1033560450-1 | SF1033560084-18 | SF1033560084-40 | |||||||||||||
Rating | ||||||||||||||||||
Price |
| $28.00 | $1,045.00 |
|
| $273.00 | ||||||||||||
Stock | ||||||||||||||||||
Availability | ||||||||||||||||||
Add to cart | ||||||||||||||||||
Description | Shipped From Abroad
The Anesthesia Workstation Model 30 is an advanced medical device featuring precise ventilation control, integrated vaporizers, safety alarms, and a user-friendly interface for efficient anesthesia delivery in surgical environments.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
| Shipped from Abroad The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation. Application Field: Neonates, Pediatrics & Adults Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV) Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| |||||||||||||
Content | Features
Safety Features
Technical SpecificationAnaesthesia main unit
Flow meter
Anaesthesia Ventilator
Respiratory Circuit
Vaporizer
|
| Two speed fan motor and two levels of flow rates. CWS 5000 can inflate a very large blanket as well as a small blanket. • Uses a DC motor, quieter and state of the art blower. • CWS 5000 is controlled and operated through a unique robust software developed by Care Essentials. • The Cocoon™ CWS 5000 is light and compact, yet very sturdy. • Designed to be user friendly. • We comply with all essential regulatory standards. We have FDA, CE, TGA, Japan Health approvals. CWS 5000 has been tested for IEC 60601-1 3rd Edition, AM 1 by UL, USA. | The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
Click Here To Download Catalogue | This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times. | Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail.
A full 8lpm O2 flowrate capability - gives better performance at lower flow rates
20psi pressure output - your anesthesia system was designed to work from pressure
O2 concentrations average 93% +/- 3%
Built-in Low O2 Concentration Alarm
Small footprint of 15"x15"x22"
Remarkably quiet
Save money over time vs. tanks
Eliminate contamination hazards of tanks coming and going in your facility
Works with ALL manufacturer's brands of anesthesia systems
| ||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||
Additional information |
Reviews
There are no reviews yet.