Features

1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip,  shoulder, ankle, wrist, elbow, and knee.

2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and  well insulated coating guarantee its safety and reliability.

3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve.

4. Tips in different shapes and angles fit in particular arthroscopic procedures.

5. Compatible with most electrosurgical generators.

Use Indication

This device should never be used when:

  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.

Reviews

There are no reviews yet.

Be the first to review “Arthroscopic Ablator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsArthroscopic Ablator removeSS-100 Smoke Evacuation System removeDisposable ECG Monitoring Electrode removeOBS-100C(I) Intelligent Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator remove
NameArthroscopic Ablator removeSS-100 Smoke Evacuation System removeDisposable ECG Monitoring Electrode removeOBS-100C(I) Intelligent Electrosurgical Unit removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator remove
Image
SKUSF1033560130165-13SF1033560130165-9SF1033560130165-24SF1033560130165-2SF1033560130165-1SF1033560130165-12
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The SS-100 Smoke Evacuation System is designed to protect medical staff and patients from harmful surgical smoke generated during electrosurgical procedures

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features

1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip,  shoulder, ankle, wrist, elbow, and knee. 2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and  well insulated coating guarantee its safety and reliability. 3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve. 4. Tips in different shapes and angles fit in particular arthroscopic procedures. 5. Compatible with most electrosurgical generators.

Use Indication

This device should never be used when:

  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
Experts have identified harmful smoke which contains a variety of toxic gases and vapors will occur during electrosurgical operation. Medical staff and patients exposure to the smoke in large may cause viral contamination,respiratory problems,nausea and burning eyes.To use a smoke evacuation system is the most effective way of protecting operating room staff and patients from hazards.
 
Features
  • Effective smoke removal: Captures toxic gases and vapors.
  • Compact and portable: Weighs 3.5 kg with a trolley cart for easy mobility.
  • Quiet operation: Works at 55 dB.
  • High efficiency: Processes 3.5-4.2 cubic meters of smoke per hour.
  • Automatic startup: Can be activated by an internal sensor or foot switch
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.