This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-70
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:

1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability

Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.

Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality

Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeEppendorf Pipette Tip 200ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeHawksley 1400 Haematocrit Centrifuge removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter remove
NameAtomic Absorption Spectrophotometer removeEppendorf Pipette Tip 200ul Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeHawksley 1400 Haematocrit Centrifuge removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter remove
ImageEppendorf Pipette Tip 200ul Per PackIISM VPism-C (Compact Type) Vein Probe
SKUSF1033560130127-70SF1033560084-137SF1033560060-1SF1033560084-118SF1033560090-1SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$690.00

$0.00

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-AA4530 This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features: 1. Complete automatic control system, fully PC controlled. You can quickly realize:
  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy
2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time. 3. The flame burner can automatically adjust the optimum height 4. Simultaneous preheating of eight lamps with automatic change of selection 5. Fully automatic peak search and wavelength scanning 6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection. 7. Self-absorbing background and deuterium lamp adjustment 8. Superior data processing capability Advanced Graphite Furnace Temperature Controlling Technology 1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes. 2. Fast sampling techniques are used to obtain reliable test data 3. The furnace has a fast heat-up capability for increased component flexibility 4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples 5. Can adjust the gas flow  to three different levels to suit a variety of applications 6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply. Safe and reliable flame system 1. EPC for more precise control of acetylene (C2H2) flow and easier handling 2. Highly efficient atomization system for higher sensitivity 3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc. 4. Automatic gas shut-off in case of abnormality Multifunctional Software Workstation Supports WINDOWS7 1. Rich menus make operation more convenient 2. Convenient conversion between different menus makes the process easier. 3. Multiple analysis and correction methods provide users with more choices. 4. Supports flexible storage and editing  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts. Technical specifications:
  • Speed: 11,800rpm with 24- place rotor
  • RCF: 14,000g with 24-place rotor
  • Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
  • Brake: Automatic
  • Noise: 62dB running with 24-place rotor
  • Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
  • Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
  • Weight: 5.1Kg net (without rotor)
  • Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
  • Construction: Aluminium casing with a steel lid
  • Finish: Body cream white baked enamel, with matt black baked enamel lid
 
Click Here To Download Catalogue
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A