This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-70
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:

The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features:

1. Complete automatic control system, fully PC controlled. You can quickly realize:

  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy

2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time.

3. The flame burner can automatically adjust the optimum height

4. Simultaneous preheating of eight lamps with automatic change of selection

5. Fully automatic peak search and wavelength scanning

6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection.

7. Self-absorbing background and deuterium lamp adjustment

8. Superior data processing capability

Advanced Graphite Furnace Temperature Controlling Technology

1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes.

2. Fast sampling techniques are used to obtain reliable test data

3. The furnace has a fast heat-up capability for increased component flexibility

4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples

5. Can adjust the gas flow  to three different levels to suit a variety of applications

6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply.

Safe and reliable flame system

1. EPC for more precise control of acetylene (C2H2) flow and easier handling

2. Highly efficient atomization system for higher sensitivity

3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc.

4. Automatic gas shut-off in case of abnormality

Multifunctional Software Workstation

Supports WINDOWS7

1. Rich menus make operation more convenient

2. Convenient conversion between different menus makes the process easier.

3. Multiple analysis and correction methods provide users with more choices.

4. Supports flexible storage and editing

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeAGD Erma EL-120 ELectrolyte Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeApexBio HemoSmart Gold Hemoglobin Meter remove
NameAtomic Absorption Spectrophotometer removeAGD Erma EL-120 ELectrolyte Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeDiscover 14 Panel Cup with Adulterants Per Pack removeApexBio HemoSmart Gold Hemoglobin Meter remove
ImageDrug Test Cup
SKUSF1033560130127-70SF1033560084-125SF1033560084-30SF1033560060-2SF1033560084-28SF1033560084-29
Rating
Price

$0.00

$1,320.00

$9.50

$0.00

$0.00

$55.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-AA4530 This Atomic Absorption Spectrophotometer measures the concentration of specific elements in a sample by analyzing the wavelengths of light absorbed by free atoms. This technique is highly sensitive and widely used in fields like environmental analysis, food safety, and clinical diagnostics to detect trace elements and metals.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
The atomic absorption spectrophotometer is PC-controlled and uses advanced graphite furnace temperature control technology. Its unique optical and mechanical design and various convenient features make it ideal for various industries. Here are some of its features: 1. Complete automatic control system, fully PC controlled. You can quickly realize:
  • Automatic ignition and extinguishing
  • Graphite furnace test method setting wavelength scanning and peak seeking determination
  • Selection of atomizer
  • Gas flow control
  • Advanced graphite furnace temperature control technology
  • The setting of the background deduction method
  • Elevator up and down front and back adjustment
  • Adjustment of light energy
2. Integrated floated optical platform design can improve the visual system shock resistance and keep it stable though using the optical signal for a long time. 3. The flame burner can automatically adjust the optimum height 4. Simultaneous preheating of eight lamps with automatic change of selection 5. Fully automatic peak search and wavelength scanning 6. Full range of safety features, including flame anomalies, gas leaks, under-pressure alarms and automatic safety protection. 7. Self-absorbing background and deuterium lamp adjustment 8. Superior data processing capability Advanced Graphite Furnace Temperature Controlling Technology 1. PID technology ensures more accurate temperature control even with voltage fluctuations and resistance changes. 2. Fast sampling techniques are used to obtain reliable test data 3. The furnace has a fast heat-up capability for increased component flexibility 4. It can be powered by a 220V power supply with a maximum heating capacity set to 20 levels for testing different samples 5. Can adjust the gas flow  to three different levels to suit a variety of applications 6. The Atomic absorption spectrophotometer has an alarm system that alerts the user during a low gas or water supply. Safe and reliable flame system 1. EPC for more precise control of acetylene (C2H2) flow and easier handling 2. Highly efficient atomization system for higher sensitivity 3. High safety with automatic alarms for flame anomalies, power failures, insufficient pressure, etc. 4. Automatic gas shut-off in case of abnormality Multifunctional Software Workstation Supports WINDOWS7 1. Rich menus make operation more convenient 2. Convenient conversion between different menus makes the process easier. 3. Multiple analysis and correction methods provide users with more choices. 4. Supports flexible storage and editing  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA4530
Wavelength Range 190-900nm
Spectral Bandwidth 0.1/0.2/0.4/1.0/2.0 nm
Accuracy of the Wavelength ±0.15nm
Receptivity of the Wavelength ≤0.04nm
Base Line Stability ≤0.002A/30min (Cu)
Characteristic Viscosity 0.02μg/ml/1% (Cu)
Checking Limit 0.004μg/ml (Cu)
Preciseness 0.005
Grating 1800 lines/mm
Inflamer All-metal titanium burner
Atomizer Effective glass atomizer
Lamp Stand 8
D2 Background Correction Ability When the background is 1A, the background ability should be deducted not less than 50 times, self absorption background deduction method
Power Source 220V±22V AC
Shipping Size(W×D×H)(mm) 860×705×755(Main instrument)
1170×645×900(Accessories)
G.W. (kg) 105 (Main instrument); 100 (Accessories)
Flame System
Acetylene Air Burner 100mm
Lgnition Dynamic Baseline Drift ≤0.006A/30min
(Cu) Characteristic Viscosity ≤0.025μg/ml/1%
Related Standard Deviation of the Accuracy ≤0.5% (Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Safety System Can automatically cut off the gas when the pressure is not enough the power is off flame out and unconformity of the burner
Graphite Furnace
The Highest Temperature 3000℃
The Largest Temperature Rising Speed ≥2000℃/s
Characteristic Quantity Cd≤0.5×10-12g Cu≤0.5×10-11g
Accuracy Cu≤3% Cd≤3%
Size (mm) and Weight 730×625×700; 79.3kg
Safety System Over current protection
Low air pressure alarm/protection
Low cooling water flow alarm/protection
Power Source and Power 220V±22V AC 7000W
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
Twenty Five (25) Test Strip per Packskyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
HemoSmart GOLD offers a fast and easy way to measure hemoglobin level and is the first biosensor-based palm sized hemoglobin testing system in the world.The one of its kind strip-based testing method offers ease of use and portability and requires only 1μL of blood. Feature
  • LCD Backlight
  • Small Blood Sample
  • Splash Proof
  • Strip Ejection
  • Hgb/Hct
  • Fast Result
Specification
  • Measurement Range: 0-24.0 g/dL
  • Power Supply: 3A battery X 2
  • Testing Time (seconds): 5 seconds
  • Sample Volume (μL): 1 μL
  • Memory Capabilities: 100 sets with date and time
  • Operating Temperature (°C): 10 °C~40 °C
 
Click Here To Download Catalogue