Atomic Absorption Spectrophotometer

$0.00

Shipped From Abroad

The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-34
Brands:: Scitek

Description

Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages

1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.

2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically.

3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.

Applications

The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.

 

Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system

Reviews

There are no reviews yet.

Be the first to review “Atomic Absorption Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAtomic Absorption Spectrophotometer removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeAlcohol Pad Per Pack removeAvalun 48 INR Microcuvette removeErma B-111 Bilirubin Meter remove
NameAtomic Absorption Spectrophotometer removeiSED Fully Automated ESR Analyzer removePlastic Urine Container Per Pack removeAlcohol Pad Per Pack removeAvalun 48 INR Microcuvette removeErma B-111 Bilirubin Meter remove
ImageAvalun 48 INR Microcuvette
SKUSF1033560130127-34SF1033560084-129SF1033560084-106SF1033560084-64SF1033560084-74SF1033560084-6
Rating
Price

$0.00

$0.00

$8.20

$4.25

$0.00

$715.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad The atomic absorption spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Atomic Absorption Spectrophotometer Features:
  1. Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements.
  2. It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matched automatically.
  3. Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
  4. Total reflection optical system, full-band achromatic, automatic wavelength scanning, automatic peak search.
  5. Both the flame and graphite furnace systems have deuterium lamps and self-priming background subtraction to meet the detection needs of complex matrix samples.
  6. Full titanium burner, stable combustion and fast heat balance.
  7. Longitudinal heating graphite furnace technology achieves uniform temperature of the graphite tube.
  8. Reliable multiple protection systems, real-time flame monitoring, acetylene leakage monitoring and protection, real-time monitoring of abnormal pressure, and cooling water monitoring.
  9. The graphite furnace atomization system has alarm functions for insufficient cooling water flow, insufficient argon pressure, excessive temperature of the graphite furnace, abnormal power supply temperature, and poor contact during graphite tube installation, and automatically cuts off the temperature rise program to ensure the safety of the operation and use process.
Advantages
1.Equipped with a complete software and hardware system, it is highly intelligent, easy to use and simple to operate, and meets the requirements of authority management, audit tracking and other requirements. 2.It has both flame and graphite furnace atomizers. The two test modes can be switched freely and matchedautomatically. 3.Fully automatic eight-lamp position rotating lamp stand, automatic switching, free setting of work lamp/preheating lamp, automatic call of optimal analysis parameters and analysis conditions.
Applications
The Atomic Absorption Spectrophotometer is widely used in the analysis of major and trace elements in metallurgy, geology, mining, petroleum, light industry, agriculture, medicine, health, food and environmental monitoring.  
Atomic Absorption Spectrophotometer Specifications:
Model SP-AA3638 SP-AA3668
Optical System Optical System Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Grating 1800 lines/mm, scintillation wavelength 250nm
Spectral Bandwidth (nm) 0.1, 0.2, 0.4, 0.7, 1.4, 2nm
Automated slit selection
Wavelength Range (nm) 185-900nm
Wavelength Accuracy (nm) 0.20 nm 0.15nm
Wavelength Repeatability (nm) ≤0.10nm ≤0.05nm
Spectral Bandwidth Deviation ±0.02 nm
Lamp Stand 8
Element Lamp Type Cu lamp, Cd lamp(Standard accessory)
Other element lamp is optional accessory
Photometric Performance Reading Mode Transmittance, absorbance, concentration
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ±0.003A/30min ±0.003A/30min
Dynamic Baseline Drift (Cu) ±0.005A/15min ±0.005A/15min
Background Correction Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional) Deuterium lamp≥ 40x (1Abs), self-priming≥ 80x (1Abs) (optional)
Flame System Characteristic Concentration (Cu) ≤0.035ug/ml ≤0.035ug/ml
Detection Limit (Cu) ≤0.006ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤0.6% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Burner Lift Automatic lifting
Burner Head Titanium 100mm burner
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion-resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.8pg,Cu≤20pg Cd≤0.8pg,Cu≤20pg
Detection Limit Cd≤1.0pg,Cu≤10pg Cd≤0.8pg,Cu≤5pg
Repeatability(Cd) RSD≤3% RSD≤2.5%
Heating Range of Graphite Furnace Room temperature-3000℃
High Power Heating Range 1500-3000℃
Slope and Holding Time 1s-255s
Heating Rate Maximum heating rate 2000°C/s
Atomization Heating Mode Light-controlled heating, Time-controlled heating, General heating
Protective Gas Flow Outside Pipe 1 L/min
Protective Gas Flow Inside Pipe 4-speed adjustable (0, 50, 200, 250ml/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Data Processing Measuring Method Measuring method
Concentration Calculation Method Concentration calculation method
Repeat Measurement Times Repeat measurement times
Report Printing Report printing
Other Computer External connect
Ambient Temp 10℃-30℃
Ambient Humidity 40%-85%
Power Supply 220V, 50/60HZ
External Size (WxDxH)(mm) 830x650x560
Shipping Size (WxDxH)(mm) 1000x780x810
N.W./G.W. (kg) 110/130
Standard Accessory Software, Cd Hollow cathode lamp, Pipette
Optional Accessory Computer, Printer, Autosampler, Recirculating cooling water system
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar