New

Auto Lensmeter D-910

$0.00

Shipped From Abroad

An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.

Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision
    Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed

Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.

  • Versatility

Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.

  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

Reviews

There are no reviews yet.

Be the first to review “Auto Lensmeter D-910”

Your email address will not be published. Required fields are marked *

Quick Comparison

Auto Lensmeter D-910 removeTonometer removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan removeView Tester (Manual Phoropter) removeAuto Lensmeter TL-6500B removeManual lensmeter remove
NameAuto Lensmeter D-910 removeTonometer removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan removeView Tester (Manual Phoropter) removeAuto Lensmeter TL-6500B removeManual lensmeter remove
ImageMecan Tonometer YZ7AMecan SW-1000 Ophthalmic Ultrasound Scanner-A-ScanMecan VT-8 View Tester (Manual Phoropter)Mecan Auto Lensmeter TL-6500BMecan Manual lensmeter NJC-4
SKUSF1033560107-9SF1033560107-27SF1033560107-26SF1033560107-20SF1033560107-22
Rating
Price

$0.00

$220.00

$1,815.00

$858.00

$770.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check archive
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Ship from abroad
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • 7.0-inch color LCD touch panel.
  • Hartman sensor with 108 multiple measure points.
  • Green measurement light beam.
  • Dyeing lens, sunglasses measured easily.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.
Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed
Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.
  • Versatility
Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.
  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
Feature:
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by a pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check the archive
Technical Specifications:
Model SW-1000 Ophthalmic A Scan Biometer
A Scan
A scan probe 10MHz import small size probe, built-in luminotron
Measuring range 15mm-40mm
Measurement precision ±0. 05mm; with macula lutea trace function
Measurement Anterior chamber depth, lens thickness, vitreous body length, total length and average
Method of measurement immersion and contact
Eye mode Phakic/ Aphakic/Dense/ various IOL
IOL formula SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS
Storage 10 cases, 5 readings each case
Output

A scan waveform and IOL calculation sheet

Features:
  • Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
  • Durable and easy to operate
  • Easily and intuitively read the sphere focal scale value
  • High eco-friendly materials
  • Design fitting the face curve and no stimulation
  • Easy to take and clean
  • Free switch between the cross-cylindrical lens and the rotary prism
  • When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
  • It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture “R”:Retinoscope lens “R”:Retinoscope lens “R”:Retinoscope lens *Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters “P”:Polaroid * it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision “RMV”:Red Vertical maddox *Be used to examine Implicit strabismus “RMH”:Red horizontal maddox *Be used to examine Implicit strabismus “WMV”:Plane Vertical Maddox *Be used to examine Implicit strabismus “WMH”:Plane horizontal maddox *Be used to examine Implicit strabismus “RL”:Red lens *Be used to examine eye function, Blending function and Implicit strabismus “GL”:Green lens *Be used to examine eye function, Blending function and Implicit strabismus “+”:Test mark of optical center adjustment “+.12”:Dioptric of the Spherical Lens is +0.12m-1 *Be used for the semi-adjustment of sphere lens, 0.25m-1 “PH”:1mmPinhole lens *Be used to exclude visual non-refractive errors of the tested eye “6ΔU”:6ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “10ΔI”:10ΔBottom-up prism *Be used to examine the rotating prism with the detection of nearly horizontal squint “±0.50”:Cross-cylindrical lens *Be used to examine the corrected dioptric of the Presbyopia and spherical lens “OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
Features:
  • 7.0-inch color LCD touch panel.
  • Hartman sensor with 108 multiple measure points.
  • Green measurement light beam.
  • Dyeing lens, sunglasses measured easily.
Technical Specifications:
  • Sphere lenses: 0~±25D
  • Cylinder lenses: 0~±10D
  • Cylinder Axis Angle: 0°~180°
  • Add.:0~10D
  • Power supply: 100~240V, 50/60HZ, 30W
  • Weight: 5kg
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare