Auto Lensmeter D-910

$0.00

Shipped From Abroad

An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: zbxyoptics

Description

The Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.

Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision
    Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed

Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.

  • Versatility

Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.

  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

Reviews

There are no reviews yet.

Be the first to review “Auto Lensmeter D-910”

Your email address will not be published. Required fields are marked *

Quick Comparison

Auto Lensmeter D-910 removeEar Irrigation and acumen removal removeAutomatic Computer Goldmann (Visual Field Analyzer) removeTonometer removeManual lensmeter removeHandheld Digital Auto-refractometer remove
NameAuto Lensmeter D-910 removeEar Irrigation and acumen removal removeAutomatic Computer Goldmann (Visual Field Analyzer) removeTonometer removeManual lensmeter removeHandheld Digital Auto-refractometer remove
ImageMecan Tonometer YZ7AMecan Manual lensmeter NJC-4Mecan AutoSight MCE-900 Handheld Digital Autorefractometer
SKUSF103356013012SF103356013013SF1033560107-9SF1033560107-22SF1033560107-2
Rating
Price

$0.00

$0.00

$3,850.00

$220.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An auto lensmeter D-910 measures the prescription of eyeglass lenses. It determines sphere, cylinder, axis, prism and distance between each optical center (pupillary distance). The lensometer is also used to accurately mount lenses into their frames as well as for orienting and marking lenses prior to cutting the lenses.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentThe Auto Lensmeter D-910 is a high-precision, fast, and versatile lens measuring device. It captures sphere, cylinder, axis, prism, PD, PH, and PCL in just 0.1 seconds. With a capacitive touchscreen, multi-wavelength detection, and multiple connectivity options, it ensures reliability, accuracy, and efficiency in optical practices.
Features
  • Measures sphere, cylinder, axis, prism, pupillary distance (PD), pupillary height (PH), and progressive channel length (PCL).

  • High-resolution capacitive touch panel for easy operation.

  • Simultaneous multi-wavelength measurement for advanced accuracy.

  • Four connectivity modes: Bluetooth, RS-232, USB, and Wi-Fi.

  • Stable magnetic sliding nosepiece and refined lens holder.

  • Fast measurement speed of approximately 0.1 seconds.

Benefits of Auto Lensmeter D-910
  • Precision Auto lensmeter D-910 uses advanced technologies to provide precise and reliable refraction measurements, reducing the risk of human error.
  • Speed
Auto lensmeter D-910 can quickly and efficiently measure lens power, allowing eye care professionals to see more patients in less time.
  • Versatility
Auto lensmeter D-910 can be used for a variety of measurements, including pupillary distance measurement, optical center height, automatic measurement taking, etc., offering great versatility for eye care professionals.
  • Complete optical measurements in one device, suitable for all lens types.

  • User-friendly touchscreen ensures fast, intuitive operation.

  • Multi-wavelength analysis enhances accuracy for coated and treated lenses.

  • Flexible connectivity options streamline data sharing and workflow.

  • Robust design with improved marking and lens holding for consistent results.

  • Ultra-fast readings improve patient flow and clinic efficiency.

Technical Specifications

Measurement Capabilities

  • Sphere: ±25 D (steps: 0.01 / 0.12 / 0.25 D)

  • Cylinder: ±9.99 D (steps: 0.01 / 0.12 / 0.25 D)

  • Axis: 0°–180° (1° increments)

  • Addition (Add): ±9.99 D

  • Prism: Up to 15 D (steps: 0.01 / 0.12 / 0.25 D)

  • Pupillary Distance (PD): 40–90 mm, 0.5 mm increments

  • Lens Diameter Range: 12–112 mm

  • Measurement Speed: Approx. 0.1 seconds per lens

  • Abbe Number: 30–60

Display & User Interface

  • 7-inch TFT LCD capacitive touchscreen

  • Automatic recognition of single-vision, progressive, and contact lenses

Connectivity & Printing

  • Communication: Bluetooth, RS-232, USB, Wi-Fi

  • Built-in thermal printer

Physical & Electrical Specifications

  • Dimensions: 180 × 255 × 455 mm

  • Packaging Size: 620 × 390 × 390 mm

  • Weight: Approx. 12 kg

  • Power Supply: AC 100–240 V, 50/60 Hz, approx. 25 VA

Features: ●Professional Same ear wax removal tool as those used by doctors, you can easily eliminate ear wax buildup at home, really save your money and time on medical visiting. Safe and Environmentally Friendly. ●Quick & Easy This ear wax removal kit is a quick, effective treatment for excess ear wax buildup. Fill the bottle with solution, Twist on the disposable tip, Use the trigger handle to spray solution into the ear canal. So Easy. ●Standard Capacity of the ear cleaner solution bottle is 10.6Oz, it has the most suitable size to hold in hand. Working at condition 32-122℉(0-50℃). Recommend to fill 1/5 of the bottle with OTC hydrogen peroxide, and 4/5 with very warm water. ●Complete Ear Washer System Our earwax removal kit comes with 1× Ear Washer Bottle, 1× Wash Basin, 1× Rubber Bulb, 1× Short Injection Head, 1× Long Hose Injection Head, 5× Disposable Tip, 1× User Manual.The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals. Technical Specifications:
  • Eyepiece focusing range: ±5D
  • The top point diopter measuring range: 0—±20D
  • The minimum measuring square value: 0.125D
  • The shuttle lens measuring range: 5A
  • The shuttle lens square value: 1A
  • The cylinder lens axial range: 0—180°
  • The cylinder lens axial square value: 5°
  • The maximum diameter of the measured lenses l00m/m
  • Power supply: AC 110V-6V DC 3V
  • Note: This item is AC 110V; The battery is not included!
 
Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing. Features of Handheld Digital Auto-refractometer:
  • Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
  • Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
  • Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item Range Interval Tolerance
Spherical (S) Myopia Mode -9.00D~ +2.50D 0.25D ±0.50D or ±20% (whichever is greater)
Normal Mode -6.00D  ~ +8.00D
Cylindrical(C) -3.00D~0.00D 0.25D ±0.50D or ±20% (whichever is greater)
Axis(A) 0°~180° ±5°
 
WeightN/AN/AN/AN/AN/AN/A