The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130181-5
Brands:: AVE

Description

Parameters Detected

Microscopy Measurement

  • RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.

Chemistry Measurement

  • pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
  • H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
  • Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
  • Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
  • Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
  • β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
  • Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
  • Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
  • Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle

Microscopy Measurement: Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically.

Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.

Product Features

Integrated

  • Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.

Multifunctional

  • Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together

More results

  • Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.

Chemistry Measurement

  • Automatic incubation and results interpretation effectively avoid the possibility of human interference.
  • Flexible options of rapid test kits in accordance with clinical purpose.

Microscopy Measurement

  • Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
  • Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
  • Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
  • Throughput: ≥120 tests/h
  • Detection rate: ≥90% for sample at concentration of 5 cells/µl
  • Accuracy: For microscopy measurement -≥95%
  • For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.

Repeatability:

For microscopy measurement:

 

concentration(cells/μl)   50          200
(CV%) ≤25%         ≤15%

 

For chemistry measurement: CV≤1%

  • Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
  • for chemistry measurement- cross test of negative and positive reference solution, no false positive
  • Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
  • Sampler:Loading capacity of 60 samples in racks
  • STAT: available
  • Result storage:≥1,000,000 results
  • Printer:External laser
  • Interfaces:Bidirectional data transmission with LIS/HIS
  • Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports

 

Reviews

There are no reviews yet.

Be the first to review “AVE-320 Vaginal Secretions Analyzer”

Your email address will not be published. Required fields are marked *

Quick Comparison

AVE-320 Vaginal Secretions Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeErma B-111 Bilirubin Meter removeAutomatic Pipette removeAGD Erma EL-120 ELectrolyte Analyzer removePlastic Urine Container Per Pack remove
NameAVE-320 Vaginal Secretions Analyzer removeEppendorf Pipette Tip 200ul Per Pack removeErma B-111 Bilirubin Meter removeAutomatic Pipette removeAGD Erma EL-120 ELectrolyte Analyzer removePlastic Urine Container Per Pack remove
ImageEppendorf Pipette Tip 200ul Per Pack
SKUSF1033560130181-5SF1033560084-137SF1033560084-6SF1033560084-130SF1033560084-125SF1033560084-106
Rating
Price

$0.00

$0.00

$715.00

$0.00

$1,320.00

$8.20

Stock
Availability
Add to cart

DescriptionShipped From Abroad The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Parameters Detected
Microscopy Measurement
  • RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.
Chemistry Measurement
  • pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
  • H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
  • Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
  • Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
  • Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
  • β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
  • Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
  • Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
  • Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle
Microscopy Measurement: Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically. Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.
Product Features

Integrated

  • Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.
Multifunctional
  • Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together
More results
  • Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.
Chemistry Measurement
  • Automatic incubation and results interpretation effectively avoid the possibility of human interference.
  • Flexible options of rapid test kits in accordance with clinical purpose.
Microscopy Measurement
  • Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
  • Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
  • Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
  • Throughput: ≥120 tests/h
  • Detection rate: ≥90% for sample at concentration of 5 cells/µl
  • Accuracy: For microscopy measurement -≥95%
  • For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.
Repeatability: For microscopy measurement:  
concentration(cells/μl)   50          200
(CV%) ≤25%         ≤15%
  For chemistry measurement: CV≤1%
  • Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
  • for chemistry measurement- cross test of negative and positive reference solution, no false positive
  • Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
  • Sampler:Loading capacity of 60 samples in racks
  • STAT: available
  • Result storage:≥1,000,000 results
  • Printer:External laser
  • Interfaces:Bidirectional data transmission with LIS/HIS
  • Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports
 
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
WeightN/AN/AN/AN/AN/AN/A