AVE-320 Vaginal Secretions Analyzer
$0.00
Shipped From Abroad
The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Parameters Detected
Microscopy Measurement
- RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.
Chemistry Measurement
- pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
- H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
- Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
- Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
- Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
- β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
- Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
- Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
- Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle
Microscopy Measurement:Â Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically.
Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.
Product Features
Integrated
- Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.
Multifunctional
- Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together
More results
- Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.
Chemistry Measurement
- Automatic incubation and results interpretation effectively avoid the possibility of human interference.
- Flexible options of rapid test kits in accordance with clinical purpose.
Microscopy Measurement
- Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
- Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
- Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
- Throughput: ≥120 tests/h
- Detection rate: ≥90% for sample at concentration of 5 cells/µl
- Accuracy: For microscopy measurement -≥95%
- For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.
Repeatability:
For microscopy measurement:
concentration(cells/μl) |  50 |         200 |
(CV%) | ≤25% |        ≤15% |
For chemistry measurement: CV≤1%
- Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
- for chemistry measurement- cross test of negative and positive reference solution, no false positive
- Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
- Sampler:Loading capacity of 60 samples in racks
- STAT: available
- Result storage:≥1,000,000 results
- Printer:External laser
- Interfaces:Bidirectional data transmission with LIS/HIS
- Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports
Quick Comparison
Settings | AVE-320 Vaginal Secretions Analyzer remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Discover 5 Panel Cup with Adulterants Per Pack remove | 8 Bucket Centrifuge remove | Erma B-111 Bilirubin Meter remove | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | AVE-320 Vaginal Secretions Analyzer remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Discover 5 Panel Cup with Adulterants Per Pack remove | 8 Bucket Centrifuge remove | Erma B-111 Bilirubin Meter remove | ||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||
SKU | SF1033560084-65 | SF1033560084-109 | SF1033560084-23 | SF1033560084-114 | SF1033560084-6 | |||||||||||||||||||||
Rating | ||||||||||||||||||||||||||
Price |
|
| $350.00 |
| $72.50 | $715.00 | ||||||||||||||||||||
Stock | ||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||
Description | Shipped From Abroad
The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
| In stock
| Shipped From AboardÂ
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||
Content | Parameters DetectedMicroscopy Measurement
Work PrincipleMicroscopy Measurement:Â Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically. Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.Product FeaturesIntegrated
Technical Parameters
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Features:
|
All-in-One Design
| 800-1 Â electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| ||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.