New

AVE-320 Vaginal Secretions Analyzer

$0.00

Shipped From Abroad

The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: AVE

Description

Parameters Detected

Microscopy Measurement

  • RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.

Chemistry Measurement

  • pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
  • H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
  • Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
  • Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
  • Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
  • β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
  • Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
  • Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
  • Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle

Microscopy Measurement: Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically.

Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.

Product Features

Integrated

  • Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.

Multifunctional

  • Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together

More results

  • Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.

Chemistry Measurement

  • Automatic incubation and results interpretation effectively avoid the possibility of human interference.
  • Flexible options of rapid test kits in accordance with clinical purpose.

Microscopy Measurement

  • Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
  • Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
  • Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
  • Throughput: ≥120 tests/h
  • Detection rate: ≥90% for sample at concentration of 5 cells/µl
  • Accuracy: For microscopy measurement -≥95%
  • For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.

Repeatability:

For microscopy measurement:

 

concentration(cells/μl)   50          200
(CV%) ≤25%         ≤15%

 

For chemistry measurement: CV≤1%

  • Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
  • for chemistry measurement- cross test of negative and positive reference solution, no false positive
  • Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
  • Sampler:Loading capacity of 60 samples in racks
  • STAT: available
  • Result storage:≥1,000,000 results
  • Printer:External laser
  • Interfaces:Bidirectional data transmission with LIS/HIS
  • Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports

 

Reviews

There are no reviews yet.

Be the first to review “AVE-320 Vaginal Secretions Analyzer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAVE-320 Vaginal Secretions Analyzer removeAvalun LabPad Device removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 5 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter remove
NameAVE-320 Vaginal Secretions Analyzer removeAvalun LabPad Device removeZenithlab (IB-9025A) Laboratory Incubator removeDiscover 5 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter remove
ImageAvalun Labpad machineDrug Test Cup
SKUSF1033560084-65SF1033560084-109SF1033560084-23SF1033560084-114SF1033560084-6
Rating
Price

$0.00

$0.00

$350.00

$0.00

$72.50

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The AVE-320 Vaginal Secretions Analyzer automates the multiparametric analysis of vaginal fluid samples, delivering accurate diagnostic results in under 5 minutes. Its compact design and high‑hygiene disposable components make it ideal for gynecological diagnostics and routine screenings.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Parameters Detected
Microscopy Measurement
  • RBC, WBC, Epithelial Cells, Clue Cells, Trichomonas Vaginalis, Bacteria, Fungus, Cleanliness,Bacterial Density and Diversity, Dominant Bacteria, Pathogenic Microorganisms, Nugent score, AV score, etc.
Chemistry Measurement
  • pH:An important indicator reflecting the micro-ecologicalbalance of vaginal.
  • H2O2:Used to assess the quantity of dominant lactobacillus for maintaining vaginal micro-ecological balance.
  • Leukocyte Esterase(LE):Inflammatory response markerreflecting the quantity of WBC in vaginal secretions.
  • Alkaline Phosphatase(ALP):Positive results indicate vaginal inflammation.
  • Neuraminidase(SNa):Secreted by gardnerella vaginalis and some anaerobic bacteria.It’san indicator of pathogenic bacteria, positive results indicate bacterial vaginosis.
  • β-Glucuronidase(β-G):An enzyme secreted by aerobic bacteria, positive results indicate aerobic vaginitis.
  • Proline Aminopeptidase(PLD):Positive results indicate colpomycosis or anaerobic vaginitis.
  • Acetylglucosaminidase(NAG):An specific enzyme secreted by fungi and trichomoniasis, together with reference to pH, fungal vaginitis(pH<4.5)and trichomonas vaginitis(pH>5.0)can be indicated.
  • Coagulase(CG):An enzyme synthesized and secreted by aerobic bacteria,of which positive results indicate aerobic vaginitis.
Work Principle
Microscopy Measurement: Machine Vision Technology is applied to scan and capture full-view field images of formed elements in secretionssamples, and thenidentify, classifyand count them automatically. Chemistry Measurement: Images of colorations from rapid test kits reacted with samples are captured and automatically interpreted.
Product Features

Integrated

  • Unique design of integration, chemistry measurement and microscopy measurement can be done by one stop sampling with easier operation and more precise results.
Multifunctional
  • Measurement modes optional: chemistry or microscopy alone or chemistry and microscopy together
More results
  • Chemistry and Microscopy measurements done together makes comprehensive score of vaginal micro-ecological environment, improves the rate of clinical diagnosis, confirm the type of vaginitis by one stop and guide the clinical treatments.
Chemistry Measurement
  • Automatic incubation and results interpretation effectively avoid the possibility of human interference.
  • Flexible options of rapid test kits in accordance with clinical purpose.
Microscopy Measurement
  • Full-view field scanning and automated locating under LP, and automated tracking, identifying, classifying and counting of particles under HP to increase positive detection rate
  • Comprehensive report with both full-view field and segmented images, on-screen verification of suspicious particles and no manual microscopic review required.
  • Accuracy of automatic identification can be continuously improved by software upgrading.
Technical Parameters
  • Throughput: ≥120 tests/h
  • Detection rate: ≥90% for sample at concentration of 5 cells/µl
  • Accuracy: For microscopy measurement -≥95%
  • For chemistry measurement –Testing results and the reference solution are within 1 tolerance level; no false positive and false negative.
Repeatability: For microscopy measurement:  
concentration(cells/μl)   50          200
(CV%) ≤25%         ≤15%
  For chemistry measurement: CV≤1%
  • Carryover: for microscopy measurement- at concentration of 5000cells/ul:≤1cells/µl
  • for chemistry measurement- cross test of negative and positive reference solution, no false positive
  • Report: comprehensive report showing both images and diagrams, with microscopy images, morphological analysis results, chemistry results
  • Sampler:Loading capacity of 60 samples in racks
  • STAT: available
  • Result storage:≥1,000,000 results
  • Printer:External laser
  • Interfaces:Bidirectional data transmission with LIS/HIS
  • Network function:connectable to the networks of laboratory and hospital to realize paperless transmission of reports
 
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
Features:
  • Microprocessor control.
  • Digital display setting and actual temperature.
  • Over temperature alarm, PID self-tuning.
  • Digital display running timer.
  • Stainless steel interior.
  • Electricity leakage protection.
  • With glass inner door, With hidden door locks.
  • Mechanical overheat protection, cut off the heating sources.
  • Automatic alarm after operation.
  • Suitable for constant temperature tests.
  • Suitable for bacteria cultivation, breeding, ferment.
  Technical Specification: Model: IB-9025A Working size: 250x250x250mm/9.84x9.84x9.84inch Power: 150W Temperature range: Room temperature+5~65℃ Temperature resolution: 0.1℃ Temperature fluctuation: ±0.5℃ Timer: 0-9999min Voltage: 110V 60Hz / 220V 50Hz Dimension: 380x370x580mm/14.96x14.57x22.83inch Size: 52cm*46cm*75cm / 20.5in*18.2in*29.6in Gross Weight:42kg / 93lb Net Weight: 23kg / 51lb Warranty: 1 year
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare