Experience cutting‑edge urine sediment analysis with the AVE‑763 Urine Formed Elements Analyzer. This innovative device harnesses advanced digital imaging and AI algorithms to rapidly and accurately quantify critical components—such as red and white blood cells, epithelial cells, casts, and crystals—in urine samples. Compact and intuitive, it’s engineered for busy clinical laboratories and point‑of‑care settings where swift, reliable diagnostics make all the difference.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: AVE

Description

Parameters Detected
  • All types of Urine Formed Elements are classified and counted, with automatic erythrocytes morphological analysis available and real images and statistical diagrams displayable and printable;
  • It is connectable to Automatic Urine Analyzers and a comprehensive report is generated;
  • Urine physical indexes are reportable;
  • Extensible tests of Hydrothoax, Cerebrospinal Fluid etc. can be done as well.
Work Principle
  • Use automated morphological microscopy technology to capture real images of urine formed elements, and then locate and track, recognize, classify and count them.
Product Features
  • Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urine;
  • Un-centrifuged urine samples at cutoff concentration level of 3-5cell/µl are detectable;
  • Automatic sampling system;
  • Automatic recognition, classification and quantitation of urine formed elements;
  • Precise erythrocytes morphological analysis helps to determine the source of hematuria;
  • Real whole view-field microscopic images of urine formed elements are presented;
  • Automatic notice of verification and on-screen verification, no additional microscopic review needed;
  • Characteristic parameters of urine formed elements are available for further clinical research;
  • Standardized and confirmatory analysis report with both images and diagrams available;
  • Self-learning ability continuously improves the recognition accuracy;
  • Unique morphological quality control available;
  • Unidirectional or bidirectional interface with LIS/HIS;
  • Software and language upgrades by USB stick;
  • Data receivable from automatic urine analyzers, customized for medium- sized laboratories.
Technical Parameters
  • Auto-detected Urine Formed Elements:  Normal red blood cells (NRBC), Abnormal red blood cells (ARBC), White blood cells (WBC), Casts (CAST), Epithelial cells( EPI), Yeast (YST), Crystals (CRYS), Mucus (MUC) and Bacteria (BAC). Further sub-classification is available with manual on-screen verification!
  • Magnification:  Standard 10X & 40X images
  • Memory:  Min. 200,000 results (including all images captured)
  • Min. Sample volume:  2.0 ml
  • Max. Sample loading number:  5 racks of 5 tubes
  • Throughput:  Up to 80 tests / hour (763A), up to 100 tests / hour (763C), up to 120 tests / hour (763B)
  • Built-in Computer:  Yes
  • Built-in Barcode reader:  Yes
  • Printer:  Laser, external, optional
  • Interfaces:  USB, RS232, LAN
  • Dimensions (main unit):  765 x 685 x 475mm (L x D x H)
  • Weight (main unit):  57kg
  • Power (main unit):  100-240V~50/60Hz, 450VA

Additional information

Weight 57 kg
Dimensions 76.5 × 68.5 × 47.5 cm

Reviews

There are no reviews yet.

Be the first to review “AVE-763 Urine Formed Elements Analyzer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsAVE-763 Urine Formed Elements Analyzer removeEppendorf Pipette Tip 20ul Per Pack remove8 Bucket Centrifuge removeAlcohol Pad Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette remove
NameAVE-763 Urine Formed Elements Analyzer removeEppendorf Pipette Tip 20ul Per Pack remove8 Bucket Centrifuge removeAlcohol Pad Per Pack removeMotic BA210 Series Biomedical Microscope removeAvalun 48 INR Microcuvette remove
ImageEppendorf Pipette Tip 20ul Per PackAvalun 48 INR Microcuvette
SKUSF1033560084-136SF1033560084-114SF1033560084-64SF1033560084-78SF1033560084-74
Rating
Price

$0.00

$0.00

$72.50

$4.25

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Experience cutting‑edge urine sediment analysis with the AVE‑763 Urine Formed Elements Analyzer. This innovative device harnesses advanced digital imaging and AI algorithms to rapidly and accurately quantify critical components—such as red and white blood cells, epithelial cells, casts, and crystals—in urine samples. Compact and intuitive, it’s engineered for busy clinical laboratories and point‑of‑care settings where swift, reliable diagnostics make all the difference.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Parameters Detected
  • All types of Urine Formed Elements are classified and counted, with automatic erythrocytes morphological analysis available and real images and statistical diagrams displayable and printable;
  • It is connectable to Automatic Urine Analyzers and a comprehensive report is generated;
  • Urine physical indexes are reportable;
  • Extensible tests of Hydrothoax, Cerebrospinal Fluid etc. can be done as well.
Work Principle
  • Use automated morphological microscopy technology to capture real images of urine formed elements, and then locate and track, recognize, classify and count them.
Product Features
  • Made strictly according to ISLH Recommended Reference Procedure for the Enumeration of Particles in Urine;
  • Un-centrifuged urine samples at cutoff concentration level of 3-5cell/µl are detectable;
  • Automatic sampling system;
  • Automatic recognition, classification and quantitation of urine formed elements;
  • Precise erythrocytes morphological analysis helps to determine the source of hematuria;
  • Real whole view-field microscopic images of urine formed elements are presented;
  • Automatic notice of verification and on-screen verification, no additional microscopic review needed;
  • Characteristic parameters of urine formed elements are available for further clinical research;
  • Standardized and confirmatory analysis report with both images and diagrams available;
  • Self-learning ability continuously improves the recognition accuracy;
  • Unique morphological quality control available;
  • Unidirectional or bidirectional interface with LIS/HIS;
  • Software and language upgrades by USB stick;
  • Data receivable from automatic urine analyzers, customized for medium- sized laboratories.
Technical Parameters
  • Auto-detected Urine Formed Elements:  Normal red blood cells (NRBC), Abnormal red blood cells (ARBC), White blood cells (WBC), Casts (CAST), Epithelial cells( EPI), Yeast (YST), Crystals (CRYS), Mucus (MUC) and Bacteria (BAC). Further sub-classification is available with manual on-screen verification!
  • Magnification:  Standard 10X & 40X images
  • Memory:  Min. 200,000 results (including all images captured)
  • Min. Sample volume:  2.0 ml
  • Max. Sample loading number:  5 racks of 5 tubes
  • Throughput:  Up to 80 tests / hour (763A), up to 100 tests / hour (763C), up to 120 tests / hour (763B)
  • Built-in Computer:  Yes
  • Built-in Barcode reader:  Yes
  • Printer:  Laser, external, optional
  • Interfaces:  USB, RS232, LAN
  • Dimensions (main unit):  765 x 685 x 475mm (L x D x H)
  • Weight (main unit):  57kg
  • Power (main unit):  100-240V~50/60Hz, 450VA
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
Weight57 kgN/AN/AN/AN/AN/A
Dimensions76.5 × 68.5 × 47.5 cmN/AN/AN/AN/AN/A
Additional information
Weight 57 kg
Dimensions 76.5 × 68.5 × 47.5 cm
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare