Description | Shipped From Abroad
- Two-part measuring board for babies up to 1 meter size
- Indelible laser engraved measuring dial
- Smooth, skin-friendly surface allows an easy and quick cleaning
- Ideal for the mobile and stationary use
- Stable head stop
- Smoothly adjustable foot stop for precise length measuring
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
This is a handhold instrument used in the dynamic clinical examination of neonatal jaundice. It non-invasively and instantly tests the transcutaneous concentration of bilirubin correlative with serum bilirubin concentration by placing it on the neonatal skin that prevents the neonates from any discomfort brought by blood drawing. Moreover it reduces the test costs and increases the working efficiency of doctors and nurses.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Patented in-house design, elegant appearance
- Steady 12.1 inch monitor, suitable for bedside and transferring
- Simple user-friendly menu, preferable for both regular LCD and touchscreen
- Unique one-key-switching for maximum 7 display interfaces
- Preinstall Plug-and-Play EtCO2 socket, simpler upgrade for ICU application
- Waterproof case in strict accordance with IPX1 on CE regulation
- Wide application for adult, pediatric and neonatal
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
Usage/Application |
Hospital |
Color |
White |
Material |
Plastic |
Application |
Hospital |
Model |
Bilipod |
Brand |
AVI |
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Suited for eliciting a full range of reflexes.
- Tapered handle base to enable plantar reflex testing.
- Nylon plastic handle. Black rubber head. PVC bumper ring.
- A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Perfectly suited for the mobile and stationary use. The two pieces of the measuring board are quickly clipped together and can be disassembled just as quickly, allowing a spacesaving storage or transport. The foot stop and the measuring boards are firmly held together by just one patent clip mechanism. Guided by a central rail, the foot stop can be used smoothly, with a measuring accuracy of 1 mm. With indelible laser engraved measuring dial. The smooth, skin-friendly surface allows an easy and quick cleaning.
Technical Data
Measuring range |
100 – 1000 mm |
Graduation |
1 mm |
Units |
cm |
Dimensions |
1260 x 280 x 90 mm |
Weight |
1.5 kg |
| This is a handhold instrument used in the dynamic clinical examination of neonatal jaundice. It non-invasively and instantly tests the transcutaneous concentration of bilirubin correlative with serum bilirubin concentration by placing it on the neonatal skin that prevents the neonates from any discomfort brought by blood drawing. Moreover it reduces the test costs and increases the working efficiency of doctors and nurses.
Features:
- It is developed with advance electronics and optics, adopting Fiber Optics, spectrum splitter, controlled spectrum
filter, NFM switching, and information processing techniques
- Accurate result, instant and safe test
- LCD display for convenient observation
- Streamline design, delicate appearance, comfortable to hold
- Long service life, low energy consumption
- Battery indicator clews battery power information and timely prompts battery replacement
- Instant test result reading, providing serum bilirubin concentration
- Storage and memory function
- Browse and delete function
- Convenient self calibration
- Easy to operate and maintenance
- Mean value computation
|
Features:
- Patented in-house design, elegant appearance
- Steady 12.1 inch monitor, suitable for bedside and transferring
- Simple user-friendly menu, preferable for both regular LCD and touchscreen
- Unique one-key-switching for maximum 7 display interfaces
- Preinstall Plug-and-Play EtCO2 socket, simpler upgrade for ICU application
- Waterproof case in strict accordance with IPX1 on CE regulation
- Wide application for adult, pediatric and neonatal
Technical Specifications:
Brand Name :PROMISE
Model Number :PRO-M12D
Certification :ISO 13485
Place of Origin :CHINA
Lead Mode :Lead Mode: 5 leads or 3 leads
Lead Selection :I, II, III, avR, avL, avF, V /or I, II, III
Gain :Auto, 2.5, 5, 10, 20mm/mV
HR Range :Adult: 15-300bpm; Ped/Neo: 15-350bpm
HRAccuracy :±1% or ±1bpm
HR Resolution :1bpm
Method :Oscillometric
Range :0-50℃
Respiration :Accuracy: ±2rpm Resolution: 1rpm
Work Mode :Manual,Auto, STAT
NIBP Range :Adult: 10-280mmHg; Ped: 10-220mmHg; Neo: 10-135mmHg
Pulse rate range :40-240bpm
Accuracy :70-100%: ±2%, <70%: unspecified Resolution : 1%
NIBP :Overpressure Protection
SpO2 :Range: 0-100%
PR range :0-250bpm
PRAccuracy :±2bpm PR Resolution: 1bpm
Temperature Channel :2
Temperature :Accuracy: ±0.1℃ Resolution: 0.1℃
Optional :Main/Side stream EtCO2, 2-IBP, 2-TEMP, Recorder, VGAOutput, Touch Screen, CentraMonitoring System, Wall mount, Trolley
Product Dimension :305(L) x 170(W) x 285(H) mm
Package Dimension :430(L) x 390(W) x 310(H) mm
Net Weight :3.2KG
Gross Weight :6.1KG
AC Power Supply :100-240V, 50/60Hz
Built-in battery :2 hours continuous work
| Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring.
Features:
- Material: clear, non-toxic PVC.
- A single-use, disposable nasal cannula.
- A highly flexible and lightweight piece with two prongs.
- Comes in an over-the-ear design to ensure premium comfort.
- Available with an anti-crush, 7 ft tubing.
- Different types of prongs are available.
- A must-have medical equipment for hospitals and more.
| Features:
- BILIPOD LED Double Surface Phototherapy Unit Sturdy Baby Trolley consists of – Collapsible Acrylic Side Panels Transparent Baby Tray with Bubble Mattress Height Adjustment and Angle Adjustment for Overhead LED Module Four Swivelling castor wheels with brakes Certified Also available - Bilipod Double Surface Phototherapy Unit with Detachable trolley
- Uniform Light Distribution with 11 High Intensity LED Lamps uniform body coverage • Observation Lamp Two Observation White LEDs provide enough light to observe the color of baby’s skin • High Irradiance Levels Irradiance > 30 µW/cm²/nm enables faster bilirubin breakdown • Pin Drop Silent Operation zero noise cooling fan • Optimum Wavelength Range: 420 to 490 nm • Very Low Power Consumption of only 30W • Effective Surface Area : 40cm x 50cm
- Life of Lamps - 30000 hours • Lamp Tilt up to 90° • Height Adjustability up to 50cm • Light Weight Lamp Unit weighs less than 3 Kg • Portable can be placed above Infant incubator or below the Infant Warmer Bassinet to give under surface Phototherapy • Sleek & Compact Lamp Unit Size : 45 x 30 x 5 cm takes minimum space • Timer: LCD Based Timer measuring Total Lamp Usage and Patient Timer
- BiliProbe Irradiance Meter Handheld Irradiance (Flux) meter for measurement of the output of conventional Phototherapy Units. Bandpass filter - 425nm to 475nm Range: 0 to 200 uW/cm²/nm Minimal Graduation: 1 uW/cm²/nm Accuracy: ± 10% Measuring Time: Approx 4-5 sec Press to ON Switch Battery: 9V Alkaline Phototherapy Eye PATCH has been designed to assure complete comfort, and eye protection for infants during Phototherapy Treatment Adjustable Band for proper comfort and secure fit Easy to use design Large eye protection pad increases light protection Single Piece wrap around design can be independently adjusted to prevent unwanted movement. Available in 3 sizes - Preterm, Term and Neonatal Phototherapy Eye Patch
Specifications:
Usage/Application |
Hospital |
Color |
White |
Material |
Plastic |
Application |
Hospital |
Model |
Bilipod |
Brand |
AVI |
|
- Suited for eliciting a full range of reflexes.
- Tapered handle base to enable plantar reflex testing.
- Nylon plastic handle. Black rubber head. PVC bumper ring.
- A reflex/patella hammer is used by medical professionals to test tendon reflexes in order to detect abnormalities in the central or peripheral nervous system.
|
Reviews
There are no reviews yet.