BEING BBC-3S1 Biosafety Cabinet

$0.00

Shipped From Abroad

This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560101

Description

This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment.

Features:

LCD large screen

Ergonomic 5 ° inclination design
Backlight design to relieve eyesight fatigue
Platform type hand rest
304 stainless steel liner
Timing function
Easy to clean and disinfect
Technical Specification:

Internal Dimensions (W×D×H) mm: 920×580×655

External Dimensions (W×D×H) mm: 1040×810×2100

Downflow Velocity: 0.33m/s

Inflow Velocity: 0.33m/s

Working Access Opening Height: 200mm

Opening MAX.: 450mm

HEPA Filter Typical Efficiency: 99.99% @ 0.3µm

Noise: <65dB

Fluorescent Lamp Intensity: >900Lux

Reviews

There are no reviews yet.

Be the first to review “BEING BBC-3S1 Biosafety Cabinet”

Your email address will not be published. Required fields are marked *

Quick Comparison

BEING BBC-3S1 Biosafety Cabinet removeAB Diagnostic HCV Ab Elisa Kit removeSyringe Needle Destroyer removeAB Diagnostic HBs Ag Elisa Kit removeAB Diagnostic FSH Elisa Kit removeAB Diagnostic HEV IgG Elisa Kit remove
NameBEING BBC-3S1 Biosafety Cabinet removeAB Diagnostic HCV Ab Elisa Kit removeSyringe Needle Destroyer removeAB Diagnostic HBs Ag Elisa Kit removeAB Diagnostic FSH Elisa Kit removeAB Diagnostic HEV IgG Elisa Kit remove
ImageHBs Ag Elisa KitHBs Ag Elisa KitFSH Elisa KitHBs Ag Elisa Kit
SKUSF1033560101SF1033560084-211SF1033560084-206SF1033560084-210SF1033560084-209SF1033560084-212
Rating
Price

$0.00

$0.00

$157.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
This product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia HBs Ag is an enzyme immunoassay for the qualitative detection of wild types and mutant variants hepatitis B surface antigen (HBsAg) in human serum or plasma.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia FSH is an enzyme immunoassay for the quantitative determination of follicle stimulating hormone (FSH) concentration in human serum.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Abia HEV IgG is an enzyme immunoassay for the qualitative detection of IgG antibodies to hepatitis E virus (HEV) in human serum or plasma. The assay is intended for screening for potentially infectious samples.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThis product has a front window operation port, through which the operator can operate inside the safety cabinet. The negative pressure air inhaled from the front window operation port is used to protect the safety of the operator; the downflow filtered by the high efficiency filter is used to protect the experimental articles in the safety cabinet; the air flow filtered by the high efficiency filter is discharged from the safety cabinet to protect the environment. Features: LCD large screen
Ergonomic 5 ° inclination design
Backlight design to relieve eyesight fatigue
Platform type hand rest
304 stainless steel liner
Timing function
Easy to clean and disinfect
Technical Specification:
Internal Dimensions (W×D×H) mm: 920×580×655 External Dimensions (W×D×H) mm: 1040×810×2100 Downflow Velocity: 0.33m/s Inflow Velocity: 0.33m/s Working Access Opening Height: 200mm Opening MAX.: 450mm HEPA Filter Typical Efficiency: 99.99% @ 0.3µm Noise: <65dB Fluorescent Lamp Intensity: >900Lux
Abia HCV Ab is an enzyme immunoassay for the qualitative detection of antibodies to hepatitis C virus (HCV) in human serum or plasma. Abia HCV Ab (D.K.067.01.3):
  • HCV Ag coated plate: 1 plate Conjugate 1: 10 ml
  • Conjugate 2 (concentrated 11-fold): 2 ml
  • Conjugate 2 diluent: 10 ml
  • HCV Ab positive control (inactivated): 2.5 ml
  • Negative control (inactivated): 2.5 ml
  • Washing solution (concentrated 25-fold): 50 ml
  • TMB (concentrated 11-fold): 2.5 ml
  • Substrate buffer: 25 ml
  • Stopping reagent 0.2M H2SO4: 25 ml
  • Protective film: 2
  • Plastic dish: 2
  • Plastic zip-lock bag: 1
Abia HCV Ab (D.K.067.05.3):
  • HCV Ag coated plate: 5 plate Conjugate 1: 50 ml
  • Conjugate 2 (concentrated 11-fold): 7 ml
  • Conjugate 2 diluent: 75 ml
  • HCV Ab positive control (inactivated): 2.5 ml
  • Negative control (inactivated): 2.5 ml
  • Washing solution (concentrated 25-fold): 240 ml
  • TMB (concentrated 11-fold): 7 ml
  • Substrate buffer: 70 ml
  • Stopping reagent 0.2M H2SO4: 90 ml
  • Protective film:10
  • Plastic zip-lock bag: 5
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
Abia HBs Ag is an enzyme immunoassay for the qualitative detection of wild types and mutant variants hepatitis B surface antigen (HBsAg) in human serum or plasma. Abia HBs Ag DK.013.01.3 (Packaging Contents):
  • HBs Ab coated plate: 1 plate
  • Conjugate 1 (concentrated 11-fold): 1.4 mlConjugate 2 (concentrated 11-fold): 1.4 ml
  • Positive control (inactivated): 2.5 ml
  • Low positive control (inactivated): 2.5 ml
  • Negative control (inactivated): 2.5 ml
  • Conjugate 1 diluent:14 ml
  • Conjugate 2 diluent: 14 ml
  • Washing solution (concentrated 25-fold): 50 ml
  • TMB (concentrated 11-fold): 2.5 ml
  • Substrate buffer: 25 ml
  • Stopping reagent 0.2M H2SO4: 25 ml
  • Protective film: 3
  • Plastic dish: 2
  • Plastic zip-lock bag: 1
  Abia HBs Ag DK.013.05.3 (Packaging Contents):
HBs Ab coated plate: 5 plates Conjugate 1 (concentrated 11-fold): 3.5 ml
Conjugate 2 (concentrated 11-fold):3.5 ml
Positive control (inactivated): 2.5 ml
Low positive control (inactivated): 2.5 ml
Negative control (inactivated): 5 ml
Conjugate 1 diluent: 36 ml
Conjugate 2 diluent: 36 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 11-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.2M H2SO4: 90 ml
HBs Ab coated plate: 5 plates Conjugate 1 (concentrated 11-fold): 3.5 ml
Conjugate 2 (concentrated 11-fold): 3.5 ml
Positive control (inactivated): 2.5 
Low positive control (inactivated): 2.5 ml
Negative control (inactivated): 5 ml
Conjugate 1 diluent: 36 ml
Conjugate 2 diluent: 36 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 11-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.2M H2SO4: 90 ml
Protective film: 15
Plastic zip-lock bag: 5
Protective film:15 Plastic zip-lock bag: 5
Abia FSH is an enzyme immunoassay for the quantitative determination of follicle stimulating hormone (FSH) concentration in human serum.
  • FSH Ab coated plate: 1 plate
  • Conjugate: 12 ml
  • Calibrator 0: 2 ml
  • Calibrator 1: 0.5 ml
  • Calibrator 2: 0.5 ml
  • Calibrator 3: 0.5 ml
  • Calibrator 4: 0.5 ml
  • Calibrator 5: 0.5 ml
  • Control serum: 0.5 ml
  • Washing solution (concentrated 25-fold): 50 ml
  • TMB/substrate solution: 12 ml
  • Stopping reagent 0.2M H2SO4: 25 ml
  • Protective film: 1
  • Plastic dish: 2
  • Plastic zip-lock bag: 1
Abia HEV IgG is an enzyme immunoassay for the qualitative detection of IgG antibodies to hepatitis E virus (HEV) in human serum or plasma. The assay is intended for screening for potentially infectious samples. Abia HEV IgG DK.029.01.3:
HEV Ag coated plate: 1 plate Sample diluent: 12 ml
Conjugate (concentrated 21-fold): 1 ml
Conjugate diluent: 20 ml
HEV Ab positive control (inactivated):1.2 ml
Negative control (inactivated): 2.5 ml
Washing solution (concentrated 25-fold): 50 ml
TMB (concentrated 21-fold): 2.5 ml
Substrate buffer: 25 ml
Stopping reagent 0.75M H2SO4: 25 ml
Protective film: 2
Plastic dish: 2
Plastic zip-lock bag: 1
Abia HEV IgG DK.029.05.3:
HEV Ag coated plate: 5 plates Sample diluent: 50 ml
Conjugate (concentrated 21-fold): 4 ml
Conjugate diluent: 75 ml
HEV Ab positive control (inactivated): 2.4 ml
Negative control (inactivated): 5 ml
Washing solution (concentrated 25-fold): 240 ml
TMB (concentrated 21-fold): 7 ml
Substrate buffer: 70 ml
Stopping reagent 0.75M H2SO4: 90 ml
Protective film: 10
Plastic dish: 0
Plastic zip-lock bag: 5
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare