Benchtop Multiparameter Water Quality Meter Features:

Highly accurate multi-parameter water quality analyzer with 8 measurement functions. They can custom setup a menu with 15 function parameters; the instrument is suitable for laboratory measurement of sample pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation.

pH Mode Characteristics:

  1. Highly accurate multi-parameter water quality analyzer with large backlit LCD.
  2. 1 to 5 point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Automatic electrode diagnostics, display pH slope and zero offset.

 

Benchtop Multiparameter Water Quality Meter Specifications:
Model MWQ-B900 MWQ-B901 MWQ-B902 MWQ-B903 MWQ-B904
pH Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point 1 point 1 point
Ion Range 0.001~19999 (depending on the range of ISE)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1 0.001,0.01,0.1,1
Accuracy ±0.5% F.S. ±0.5% F.S.
Calibration Points 1 to 5 points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°c 20/25°c
Cell Constant K=0.1, 1, 10 or custom K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1 0.01,0.1,1
Accuracy ±1% F.S. ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ 0.00~20.00MΩ 0.00~20.00MΩ
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1% 0.01mg/L, 0.1% 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1or 2 points 1or 2 points 1or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Sizes(W×D×H) 210×188×60
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2

Reviews

There are no reviews yet.

Be the first to review “Benchtop Multiparameter Water Quality Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBenchtop Multiparameter Water Quality Meter removeAlcohol Pad Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer remove
NameBenchtop Multiparameter Water Quality Meter removeAlcohol Pad Per Pack removeDiscover 5 Panel Cup with Adulterants Per Pack removePlastic Urine Container Per Pack removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer remove
ImageDrug Test CupAvalun 48 INR Microcuvette
SKUSF1033560130127-41SF1033560084-64SF1033560084-23SF1033560084-106SF1033560084-74SF1033560060-2
Rating
Price

$0.00

$4.25

$0.00

$8.20

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Benchtop Multiparameter Water Quality Meter Features:
Highly accurate multi-parameter water quality analyzer with 8 measurement functions. They can custom setup a menu with 15 function parameters; the instrument is suitable for laboratory measurement of sample pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity, dissolved oxygen concentration and saturation. pH Mode Characteristics:
  1. Highly accurate multi-parameter water quality analyzer with large backlit LCD.
  2. 1 to 5 point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Automatic electrode diagnostics, display pH slope and zero offset.
 
Benchtop Multiparameter Water Quality Meter Specifications:
Model MWQ-B900 MWQ-B901 MWQ-B902 MWQ-B903 MWQ-B904
pH Range -2.000~20.000pH
Resolution 0.001, 0.01, 0.1pH, selectable
Accuracy ±0.002pH
Calibration Points 1 to 5 points
pH Buffer Options USA, NIST, DIN, 2 custom buffers
ORP Range ±1999.9mV
Resolution 0.1, 1mV, selectable
Accuracy ±0.2mV
Calibration Points 1 point 1 point 1 point
Ion Range 0.001~19999 (depending on the range of ISE)
Resolution 0.001, 0.01, 0.1, 1
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent)
Measurement Units ppm, mg/L, mol/L, mmol/L
Calibration Points 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000)
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0.001,0.01,0.1,1 0.001,0.01,0.1,1
Accuracy ±0.5% F.S. ±0.5% F.S.
Calibration Points 1 to 5 points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear (0.0~10.0%/°C), pure water Linear (0.0~10.0%/°C), pure water
Reference Temperature 20/25°c 20/25°c
Cell Constant K=0.1, 1, 10 or custom K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 0.01,0.1,1 0.01,0.1,1
Accuracy ±1% F.S. ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
Resistivity Range 0.00~20.00MΩ 0.00~20.00MΩ 0.00~20.00MΩ
Resolution 0.01 0.01 0.01
Accuracy ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation 0.00~20.00mg/L, 0.0~200.0% saturation
Resolution 0.01mg/L, 0.1% 0.01mg/L, 0.1% 0.01mg/L, 0.1%
Accuracy ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1or 2 points 1or 2 points 1or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual 60.0~112.5kPa/ 450~850mmHg, manual
Salinity Correction 0.0~50.0g/L, manual 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements DC5V power adapter
Sizes(W×D×H) 210×188x60
Shipping Size (W×D×H)(mm) 300x250x200
N.W./G.W. (kg) 1.5/2
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C