Description | Shipped From Abroad
Model : PH-B120; PHI-B130; ION-B131
This Benchtop pH Meter with 5-Point Calibration is a laboratory instrument used for precise pH measurements. It offers high accuracy and stability, often used in research and quality control settings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Benchtop pH Meter Features:
Different
- PH-B120: Customize 15 function parameters
- PH-B130: Customize 18 function parameters
- ION-B131: Customize 15 function parameters
Same
- 7-inch TFT display, high-definition and intuitive
- 1 to 5 points calibration, automatic recognition of USA, NIST, DIN standard buffers
- Automatic temperature compensation
- Automatic calibration date, time and 1-point offset calibration
- Large storage capacity of up to 1000 entries
- Solution temperature coefficient, compensates for pure water measurements and converts readings up to 25°C.
- Automatic alarm for measurements above the set range
Benchtop pH Meter Specifications:
Model |
PH-B120 |
PHI-B130 |
ION-B131 |
pH |
Range |
-2.000-20.000pH |
-2.000-20.000pH |
_ |
Resolution |
0.001,0.01, selectable |
0.001,0.01, selectable |
_ |
Accuracy |
±0.002pH |
±0.002pH |
_ |
Calibration Points |
1 to 5 points |
1 to 5 points |
_ |
Ph Buffer Options |
USA, NIST, DIN, 5 custom buffers |
USA, NIST, DIN, 5 custom buffers |
_ |
ORP |
mV Range |
±2000.0mV |
±2000.0mV |
±2000.0mV |
Relative mV Range |
±2000.0mV |
±2000.0mV |
_ |
Resolution |
0.1mV |
0.1mV |
0.1mV |
Accuracy |
±0.2mV |
±0.2mV |
±0.2mV |
Calibration Points |
1 point |
1 point |
_ |
Ion |
Range |
_ |
0.001~30000 (depending on the range of ISE) |
0.001~30000 (depending on the range of ISE) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001, 0.01, 0.1, 1 |
Accuracy |
_ |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
±0.5% F.S. (monovalent), ±1% F.S. (divalent)) |
Measurement |
_ |
ppm, mg/L, mol/L, mmol/L |
ppm, mg/L, mol/L, mmol/L |
Units |
Calibration Points |
_ |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Methods |
_ |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Direct reading, known addition, known subtraction, sample addition, sample subtraction |
Electrode Management |
_ |
1 to 3 electrodes |
1 to 3 electrodes |
Water Hardness |
Range |
_ |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
0.05~200mmol/L, 0~1122°dH, 0~1404°e, 0~2000°fH, 0~8000mg/L (Ca2+) |
Resolution |
_ |
0.001, 0.01, 0.1, 1 |
0.001,0.01,0.1,1 |
Accuracy |
_ |
±1% F.S. |
±1% F.S. |
Calibration Points |
_ |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
2to 5points 0.01, 0.1, 1, 10, 100mmol/L) |
Temperature |
Range |
0~105°C / 32~221°F |
0~105°C / 32~221°F |
0~105°C/32~221°F |
Resolution |
0.1°C/0.1°F |
0.1°C/0.1°F |
0.1°C/0.1°F |
Accuracy |
±05°C/0.9°F |
±05°C/0.9°F |
±05°C/0.9°F |
Offset Calibration |
1 point, reading ±10°C |
1 point, reading ±10°C |
1 point, reading ±10°C |
Other Specifications |
Temperature Compensation |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
0~100°C, manual or automatic |
Solution Temperature Coefficient |
25°C |
25°C |
_ |
Stability Criteria |
Standard or high-accuracy |
Standard or high-accuracy |
Standard or high-accuracy |
Calibration Due Alarm |
1to 31 days or off |
1to 31 days or off |
1to 31 days or off |
Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
10, 30, 60 seconds, 10, 30 minutes or off |
Password Protection |
4digits |
4digits |
4digits |
Memory |
1000 data sets |
1000 data sets |
1000 data sets |
Communication Interface |
USB |
USB |
USB |
Connector |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
BNC, 3.5 mm jack socket |
Display |
7 inches TFT LCD |
7 inches TFT LCD |
7 inches TFT LCD |
Power Requirements |
DC12V power adapter |
DC12V power adapter |
DC12V power adapter |
Sizes (W×D×H)(mm) |
240×220×80 |
240×220×80 |
240×220×80 |
Shipping Size (W×D×H)(mm) |
300x250x200 |
300x250x200 |
300x250x200 |
N.W./G.W. (kg) |
1.7/2.5 |
1.7/2.5 |
1.7/2.5 |
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
- Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
- Max. speed: 14,100 x g (14,500 rpm)
- Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
- Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
- Rotor can be autoclaved at 121°C for 20 minutes
- Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
- Eliminate costly repairs with the low maintenance drive
- Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: |
800 – 13,400 rpm (100 rpm steps) |
Capacity: |
12 x 1.5/2.0 mL |
Electrical: |
120 V, 60 Hz |
Dimensions: |
(W x D x H) 22.6 x 23.9 x 12.0 cm |
Weight: |
4.3 kg |
| This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
- Lowest operation and tip ejection forces
- Fully autoclavable
- Ultra light weight with space-age materials
- Secondary adjustment option for various liquid classes
- Spring loaded tip con
- For transferring molecular samples and PCR mix solutions.
- One set is for DNA work and the other for RNA work. Each with the following specs
- Light weight, traditional tip shaft, and will fit all generic brands of tips
- Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
- Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
- Low maintenance and autoclavable 121° for at least 20 minutes
- Quick release
| Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
- Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
- Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
- Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
- Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
- For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
- For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
- Not for eyes;
- keep out of reach of children;
- For external use only;
- please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Specification - CE&ISO13485
|
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
- User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
- Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
- Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
|
FDA 510(K) & CLIA Waived
Up to 99% accuracy rate
Results in as little as 1 minute
24 Month Shelf Life from Date of Manufacture
Secure, seal and send to lab for confirmation
Built in temperature strip
Available to test up to 17 substances with adulterants or 18 without adulterants
Adulterants available
|
Reviews
There are no reviews yet.