Description | Shipped From Abroad
Model : PH-B920
The Benchtop pH Meter with 5-Point Calibration is a precise laboratory instrument for measuring pH levels. It calibrates to five standard solutions for accurate readings.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content |
Benchtop pH Meter Features:
The PH-B920 benchtop pH meter has an automatic endpoint lock, menu customization, and large storage capacity.
The benchtop pH meter is suitable for measuring samples' pH and redox potential values.
- Measurement accuracy of 0.002 pH and automatic temperature compensation ensures accuracy over the full range.
- Calibration due reminder
- Automatic electrode diagnostics, display of pH slope and zero offset
- 1 to 5 point calibration, automatic recognition of USA, NIST, and DIN standard buffers.
- USB interface, easy data transfer
- mV mode ensures reliable redox potential measurement.
Benchtop pH Meter Specifications:
Model |
PH-B920 |
pH |
Range |
-2.000~20.000pH |
Resolution |
0.001, 0.01, 0.1pH, selectable |
Accuracy |
±0.002pH |
Calibration Points |
1 to 5 points |
pH Buffer Options |
USA, NIST, DIN, 2 custom buffers |
ORP |
mV Range |
±1999mV |
Relative mV Range |
±1999mV |
Resolution |
0.1, 1mV, selectable |
Accuracy |
±0.2mV |
Calibration Points |
1 point |
Temperature |
Range |
0~105°C/32~221°F |
Resolution |
0.1°C/0.1°F |
Accuracy |
±0.5°C/±0.9°F |
Offset Calibration |
1 point, reading ±10°C |
Other Specifications |
Temperature Compensation |
0-~100°C, manual or automatic |
Stability Criteria |
Low or high |
Calibration Due Alarm |
1 to 31 days or off |
Slope/Offset Display |
Yes |
Hold Function |
Manual or auto-endpoint |
Memory |
500 data sets |
Communication Interface |
USB |
Connector |
BNC, 3.5mm jack socket |
Display |
Custom LCD(125×100mm) |
Power Requirements |
DC5V power adapter |
Sizes(W×D×H)(mm) |
210×188×60 |
Shipping Size (W×D×H)(mm) |
350x250x200 |
N.W./G.W. (kg) |
1.5/2 |
|
- Total Volume: 60mL.
- Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
- Made of premium PP material, it is durable for usage.
- Some measurements can be used to not only use urine samples, it can also be used for other liquids.
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
- Parameters: Na+,K+,Cl-, iCa++ / Li
- It works on ISE principle
- Sample Type: Whole blood, Serum, Plasma, Urine
- Low reagent consumption
- Sample requirement is only 90ul
- 60 samples per hour
- Automatic two point calibration after 4hrs and one point calibration with each sample analysis
- Air bubble detection
- Track reagents consumption and provides alerts
- For low reagent volume
- Precision testing facility to get CV and SD
- Trilevel Quality Control with LJ plots of last 30days
- Low aspiration volume
- Fast sample processing
- Accurate and Precise results
Technical Specifications:
Parameters |
Na+, K+, Cl– /Ca++ |
Principle |
Ion Selective Electrode (ISE) |
Sample Type |
Analyses whole blood, serum, plasma and urine |
Sample Volume |
≤100 µL |
Analysis Time |
≤60 seconds |
Throughout |
≤60 samples per hour |
Data Link |
Serial (RS232) |
External Interface |
USB (Keyboard, Mouse) |
Operating Condition |
10° C to 35° C, Relative Humidity up to 85% |
Storage Condition |
Temp: 10° C to 40° C |
Relative Humidity |
up to 85% non- condensing |
Power Supply |
100 to 240 VAC ±10%, 50Hz |
Dimensions |
395 x 260 x 375 mm |
Weight |
7.5 kg |
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
- Speed: 11,800rpm with 24- place rotor
- RCF: 14,000g with 24-place rotor
- Acceleration: 0-11,800rpm in 60 seconds, with 24-place rotor
- Brake: Automatic
- Noise: 62dB running with 24-place rotor
- Motor: High precision AC/DC series wound motor, brush gear, computer wound coil winding, balance armature and high speed bearings.
- Timer: 0-15 minute timer, graduated in 1 minute increments. Automatic switch at zero
- Weight: 5.1Kg net (without rotor)
- Dimensions: 23.5cm height x 27cm diameter, footprint 16cm diameter
- Construction: Aluminium casing with a steel lid
- Finish: Body cream white baked enamel, with matt black baked enamel lid
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
Principle of Measure: |
Photometrical |
Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
Tube Requirements: |
13 x 75 mm, pierceable capped tube |
Quality Control: |
Barcoded Seditrol® QC |
Barcode Reader: |
Internal |
Printer: |
Internal |
Interface Specifications: |
serial RS232 port for LIS connection |
Weight: |
14 kg |
Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
Voltage: |
100-240VAC |
Frequency Range: |
50-60 Hz |
Power: |
160W |
Click Here To Download Catalogue |
Reviews
There are no reviews yet.