Blood Pressure Monitor CT40

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130132-5
Brands:: SUNTECH

Description

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.

Features

With the Suntech CT40, you can count on us to deliver:

Quality: Clinical-grade Advantage™ BP technology

Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions

Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended)

Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi

Flexibility: Modular design for addition of optional temperature and SpO2 modules

Simplicity: Intuitive user interface with LCD display

Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi

 

Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications

SpO2 Specifications

Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM

Temperature Specifications

Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C

Blood Pressure Specifications

Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing – 700 kPa – 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing – 500 kPa – 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.

 

Reviews

There are no reviews yet.

Be the first to review “Blood Pressure Monitor CT40”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsBlood Pressure Monitor CT40 removeAccoson Sphygmomanometer removeASCO LED Examination Light removeBistos BT-770-12.1" Touchscreen Patient Monitor removeResmed AirSense10 CPAP Machine removeMIR Spirolab Spirometer remove
NameBlood Pressure Monitor CT40 removeAccoson Sphygmomanometer removeASCO LED Examination Light removeBistos BT-770-12.1" Touchscreen Patient Monitor removeResmed AirSense10 CPAP Machine removeMIR Spirolab Spirometer remove
ImageSphygmomanometerExamination LED LightBistos BT-770-12.1" Touchscreen Patient MonitorMIR Spirolab Spirometer
SKUSF1033560130132-5SF1033560084-17SF1033560084-3SF1033560059-1SF1033560084-1SF1033560084-13
Rating
Price

$0.00

$28.00

$0.00

$902.00

$0.00

$2,101.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Adult Velcro Cuff for maximum arm circumference of 34.3cm
  • Made in UK & guaranteed accurate to BS EN 1060 – 1
  • Lightweight diecast case
  • Shatter-proof plastic manometer tube
  • Mercury reservoir with isolation valve
  • Steel hinge pivots
  • Range 0 – 300mmHg
  • Supplied with adult size cuff & latex-free bulb
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out of Stock Light Intensity - 8,000 Lux ±10% Colour Temperature - 4500 K (FIXED) Number of LED - 7 Power - 220V Fixed Light Intensity Flexible arm

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock The AirSense 10 AutoSet is a premium auto-adjusting therapy device. It features AutoRamp™ with sleep onset detection, expiratory pressure relief (EPR™) and Easy-Breathe technology. The AirSense 10 AutoSet provides advanced event detection, including indications of central sleep apnoea and Cheyne-Stokes respiration.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Pediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.
Features
With the Suntech CT40, you can count on us to deliver: Quality: Clinical-grade Advantage™ BP technology Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended) Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi Flexibility: Modular design for addition of optional temperature and SpO2 modules Simplicity: Intuitive user interface with LCD display
Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi
 
Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications
SpO2 Specifications
Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM
Temperature Specifications
Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C
Blood Pressure Specifications
Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
 
  • Adult Velcro Cuff for maximum arm circumference of 34.3cm
  • Made in UK & guaranteed accurate to BS EN 1060 – 1
  • Lightweight diecast case
  • Shatter-proof plastic manometer tube
  • Mercury reservoir with isolation valve
  • Steel hinge pivots
  • Range 0 – 300mmHg
  • Supplied with adult size cuff & latex-free bulb
   
Light Intensity - 8,000 Lux ±10% Colour Temperature - 4500 K (FIXED) Number of LED - 7 Power - 220V Fixed Light Intensity Flexible arm
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
The AirSense 10 AutoSet is a premium auto-adjusting therapy device. It features AutoRamp™ with sleep onset detection, expiratory pressure relief (EPR™) and Easy-Breathe technology. The AirSense 10 AutoSet provides advanced event detection, including indications of central sleep apnoea and Cheyne-Stokes respiration. Optional pulse oximetry monitoring is also available. Modes include AutoSet and CPAP. With the wirelessly enabled AirSense 10 AutoSet patient trial devices you can stay more connected than ever before with your patients during their critical early days of adjusting to treatment. Feature
  • New AutoSet Response feature
ResMed’s AutoSet algorithm now allows for additional customisation of therapy with the new AutoSet Response feature which offers all the benefits of the enhanced AutoSet algorithm with gentler pressure increases for additional comfort.
  • Central apnoea and Cheyne-Stokes respiration detection
The AirSense 10 AutoSet differentiates between obstructive and central apnoeas and can also detect indications of Cheyne-Stokes respiration, so you can be confident that your patients are receiving appropriate therapy.
  • AutoRamp™.
This new feature with sleep onset detection starts by delivering a low pressure for greater patient comfort. Then, once the patient falls asleep, it increases the pressure to the prescribed level.
  • Built-in ambient light sensor
Adjusts the brightness of the screen based on the light in the room. So if patients need to get up during the night, the screen’s back light won’t disrupt their bed partner.
  • Easy-Breathe motor
Is whisper-quiet, offering patients and their bed partners a more peaceful night’s sleep.
  • Expiratory pressure relief (EPR)
Maintains the optimal treatment for the patient during inhalation and reduces pressure during exhalation.
  • Consistent humidification
Throughout the night with the integrated HumidAir™ humidifier with advanced HumidAir technology helps patients adjust to treatment and use therapy longer. Technical Specification
  • Special User Features: AutoRamp, Intergrated Humidifier, Heated Hose Tube
  • Pressure Range: 4cm-20cm/h2O fixed pressure setting
  • Ramp Time: Auto adjusting ramp feature
  • Starting Ramp Pressure: AutoRamp starting at 4cm/H2O
  • Filters: Standard or Hypo-Allergenic Disposable
  • Device Set-up: Set according to RX or default mode
  • Data Storage Content: SD Card or Wireless Transmission (US Only) to Provider
  • Compliance Meter: On screed display
  • Humidifier: Integrated with Optional Heated Tubing
  • DC Power: 24V ---3.75A
  • AC Power: 100-240V, 50-60Hz
  • Actual Weight: 44 oz (2.75lbs)
  • Sound Level: 26.6 dBA with uncertainty of 2 dBA
Click Here To Download Catalogue
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Paediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode. Colour screen Touchscreen 7 inches TFT display Database up to 10,000 Spirometry tests or 900 hours of Oximetry recording coupled with powerful and flexible search services. Optional function available: Oximeter with adult or paediatric finger probe. Long life Rechargeable Battery. Available with both DISPOSABLE or REUSABLE turbine flowmeter. PC based mode, using WinspiroPRO® Bluetooth® 2.1 and USB Connectivity Wireless or via cable Real Time test directly on your PC. Winspiro PRO® PC software provides Real Time Flow/Volume and Volume/Time curves with PRE/POST Bronchodilator comparison on your PC. Includes free online updates. Paediatric Incentive for Spirometry with wide choice of pictures and animations. Spirometry test after drug adminitration Bronchodilator Reversibility, Bronchial Challenge with FEV1-response curve with protocols for both Methacholine and Mannitol. Quanjer 2012-GLI Predicted values with LLN and Z-score Patient Trend Charts for easy follow-up Search engine for instant access to database. Wide choice of communication protocols for integration with EMR.
Spirometry parameters: FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/ FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).  
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare