Blood Pressure Monitor CT40

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130132-5
Brands:: SUNTECH

Description

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.

Features

With the Suntech CT40, you can count on us to deliver:

Quality: Clinical-grade Advantage™ BP technology

Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions

Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended)

Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi

Flexibility: Modular design for addition of optional temperature and SpO2 modules

Simplicity: Intuitive user interface with LCD display

Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi

 

Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications

SpO2 Specifications

Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM

Temperature Specifications

Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C

Blood Pressure Specifications

Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing – 700 kPa – 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing – 500 kPa – 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.

 

Reviews

There are no reviews yet.

Be the first to review “Blood Pressure Monitor CT40”

Your email address will not be published. Required fields are marked *

Quick Comparison

Blood Pressure Monitor CT40 removeTimesco Jumper Fingertip Pulse Oximeter removeLittman Stethoscope removeLittmann Classic III Stethoscope removeBistos BT-770-12.1" Touchscreen Patient Monitor remove2-Function Manual Hospital Bed remove
NameBlood Pressure Monitor CT40 removeTimesco Jumper Fingertip Pulse Oximeter removeLittman Stethoscope removeLittmann Classic III Stethoscope removeBistos BT-770-12.1" Touchscreen Patient Monitor remove2-Function Manual Hospital Bed remove
ImageFingertip Pulse OximeterLittman StethoscopeLittmann Classic III StethoscopeBistos BT-770-12.1" Touchscreen Patient Monitor
SKUSF1033560130132-5SF1033560084-2SF1033560084-5SF1033560084-34SF1033560059-1SF1033560084-52
Rating
Price

$0.00

$17.00

$13.20

$34.00

$902.00

$140.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

BP technology, the new SunTech CT40 is the ideal, affordable solution for clinical-grade spot-check measurements of blood pressure plus vital signs in hospitals and clinics. Ambulatory care, long-term care and low-acuity hospital departments can easily implement this versatile, user-friendly vital signs device that delivers SunTech clinical-grade performance, advanced features and digital connectivity.

Unique to the SunTech CT40, its modular design allows clinicians to easily make adaptations to the device while in the field – adding thermometry, SpO2 and Wi-Fi based solely on the needs of the patient.
Features
With the Suntech CT40, you can count on us to deliver: Quality: Clinical-grade Advantage™ BP technology Reliability: Manual SphygMode™ for real-time verification of BP readings without removing the cuff plus built-in memory for up to 99 charting sessions Accuracy: Customizable BP averaging protocol to ensure accurate, consistent readings (SPRINT recommended) Connectivity: HL7 messaging protocols for data transfer with network connection through built-in LAN/Ethernet, 2 USB ports or optional Wi-Fi Flexibility: Modular design for addition of optional temperature and SpO2 modules Simplicity: Intuitive user interface with LCD display
Options & Accessories
  • Covidien Filac® 3000 Thermometry
  • Masimo SET® SpO2 (preferred)
  • ChipOx Nellcor®-compatible SpO2
  • Mobile Stand
  • Barcode Scanner
  • Wi-Fi
 
Picture of the SunTech CT40 with available options and accessories, including the various modules.
Technical Specifications
SpO2 Specifications
Function Masimo M-LNCS DCI ChipOx
Saturation Normal (no motion) 70-100%Arms ± 2% 70-100%Arms ± 2%
Saturation Motion 70-100%Arms ± 3% N/A
Low Perfusion SpO2 +/-2% N/A
Pulse Heart rate ± 3% BPM 20-300 BPM: ±3 BPM
Pulse Heart rate w/motion ± 3% BPM 20-300 BPM: ±3 BPM
Temperature Specifications
Function Covidien Electronic Thermometer
Temperature Accuracy Quick Mode (Oral): ± 0.3°C
Temperature Accuracy Std. Mode (Aux/Rectal): ± 0.1°C
Temperature Accuracy Direct Mode ± 0.1°C
Response Time 4 sec (quick mode); 10-15 sec. (Axillary/Rectal); 60 sec.(direct mode)
Resolution 0.1°C
Blood Pressure Specifications
Specifications Values
Range:
  • Pressure: Diastolic: 20-200 mmHg (adult), 20-160 mmHg (pediatric).
  • Systolic: 40-260 mmHg (adult), 40-230 mmHg (pediatric)
  • Heart Rate: 30-220 BPM (beats per minute)
Accuracy (BP): Meets or exceeds ANSI/AAMI/ISO 81060-2:2013 standard for non-invasive accuracy (±5mmHg mean error with 8mmHg standard deviation).
General Specifications
Specifications Values
Conditions for Use: Operating: 10°C (50°F) to 40°C (104°F) 15 – 90% RH non-condensing - 700 kPa - 1060 kPa. Operating the monitor in an environment at maximum temperature can produce temperatures exceeding 41°C (41.6°C highest recorded) on a patient-applied part. It is up to the operator to determine if this temperature is too high based upon the condition of the patient and, if so, to ensure the ambient temperature of the environment is 38°C or below.
Storage: -20°C (-4°F) to 55°C (149°F) 15 – 90% RH non-condensing - 500 kPa - 1060 kPa. Performance can be affected if used or stored outside the specified temperature, humidity, or altitude listed in the ranges above.
Power: Internal power supply. Input: 100-240 VAC @ 1.5A max, 50-60 Hz. Output +9VDC @ 5A IEC 320 type input connector.
Battery: Type: 7.2v, 6600mAh Internal Lithium-Ion battery Run Time (full charge): ~20 hrs* / 200 BP cycles Charge Time: ~6 hrs @ 23deg Celsius +/- 2deg *Unit with BP, Temp, SpO2, Wi-Fi, barcode scanner
Calibration: The accuracy of cuff -pressure transducers/indicators should be verified bi-annually.
Safety Systems: Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 300 mmHg (+20/-10mmHg). Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds.
Dimensions: Size (without thermometer option): 8” H x 6.75’’ W x 5.2’’ D or 215mm H x 190mm W x 140mm D
Standards: ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, EN 60601-1:2006/A1:2013, IEC 60601-1-2: 2007 EMC, IEC 80601-2-30: 2013, ISO 80601-2-61: 2011, ISO 15223-1:2012, ISO 10993-1, 2009, ISO 10993-5, 2009, EN ISO 10993-10, 2010, ISO 81060-2:2013, EN 50419: 2006, EN ISO 14971:2009, CSA C22.2 No. 60601-1, EN ISO 81060-1: 2012, IEC 60601-1-6: 2013
Classifications: Equipment Classification: Class IIa per MDD, Class I (Electrical Shock), Continuous mode of operation, CE
Ingress of liquid: Ingress Protection: IPX1: This device is protected against harmful effects of dripping water per IEC 60529.
 
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualLittman Stethoscope Features:
  • Monitor and assess a wide range of patients
  • Detect normal and abnormal sounds and rhythms
  • Useful in non-critical care environments such as a medical office, general ward, OB/GYN, ambulatory clinic or urgent care
  • Fun and vibrant; match colour and finish to your personality
  • Designed for use with adult and pediatric patients
  • tunable, dual-sided stainless steel chest piece with open or closed bell
  • Non-chill bell sleeve for greater patient comfort
  • Soft-sealing ear-tips provide optimal comfort and excellent sound occlusion
  • Made in the USA without natural rubber latex

The Classic III stethoscope brings new design, materials, and technology to the Littmann stethoscope series that’s been used and trusted by millions of medical professionals worldwide for decades. With a two-sided chestpiece, dual tunable diaphragms, improved tubing, and much more, the Classic III stethoscope combines the best of new and traditional. Full adult and pediatric auscultation is available through its dual head chestpiece simply by rotating the central spline to alternate between the two sides. The more compact one piece diaphragm and rim assemblies have further increased acoustic sensitivity. The binaurals have been redesigned with larger diameter ear tubes and a thicker single lumen binaural to transfer sound more effectively. The selector spline is now recessed to allow a flush fit with the binaural tube and now features a visual indicator for easy identification of the operational diaphragm. Features
  • NEW: double-sided, dual diaphragm chestpiece for both adult and paediatric assessment.
  • NEW: The paediatric side is also easily transformed into a traditional open bell by replacing the single-piece diaphragm with the supplied non-chill rim.
  • NEW: chestpiece is precision-machined into an aesthetically pleasing, less angular shape.
  • NEW: single-piece diaphragm instead of separate diaphragm/rim making it easier to attach and easier to clean due to the smooth unbroken surface.
  • NEW: The stem features an open side indicator to easily identify which diaphragm is in operation.
  • NEW: next-generation tubing gives even longer tube life with improved resistance to skin oils, alcohol and staining.
  • 3M’s ‘Tunable Technology’ lets you easily switch from low to high frequency sounds by switching from light to firm pressure on both the adult and paediatric sides of the chestpiece.
  • High acoustic sensitivity when performing general physical assessment.
  • Laser engraving of text and symbols to personalise your scope and avoid theft/loss
  • Larger ear tubes on the anatomically designed headset comfortably positioned for better sound transfer. Easy adjustment by simply squeezing or pulling apart the eartubes.
  • Comfortable Snap-Tight soft seal eartips create an excellent acoustic seal to reduce ambient noise.
  • No natural rubber latex or phthalate plasticisers are used in the tubing or any other component—to help protect health and the environment.
  • Complement your personal style with Littmann’s large range of chestpiece finishes and tubing colours.
  • Used as a diagnostic aid as part of the physical assessment of a patient.
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Product Size:2125*970*540mm Packing size: 205*96*26cm/2pcs Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5° Standard Accessories: 4pcs 5” standard castor two with brake, 1 pair aluminum side rail, 2pcs ABS head and foot board, 4pcs urine hooks, 2pcs cranks system
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare