CO2 Incubator LCD Display

$0.00

Shipped From Abroad

This CO2 incubator has been specifically designed to provide performance reliability, ease of operation and value for a range of incubation needs, from basic research to demanding cutting-edge applications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-23
Brands:: Scitek

Description

CO2 Incubator Features:

For advanced uniformity and recovery, our airflow patterns are specifcally designed for outstanding distribution of critical environmental conditions (temperature, gas exchange and humidity). Forced-air fan gently and evenly distributes clean, humidifed air throughout the chamber ensuring all cells experience the same conditions without the threat of desiccation. Temperature and gas sensors are placed in the chamber to ensure the detected temperature and gas are in the same conditions.

Designed for sensitive cells and It is designed to protect valuable samples while optimizing cell growth.

1. 180°C Dry heat sterilization

2. Optional tri-gas

3. Top IR sensor

4. LCD touch screen

 

Applications of CO2 Incubator:
  1. Cell culture and cell growth
  2. Tissue engineering and regenerative medicine research
  3. Cellular virology and bacteriology experiments
  4. Drug screening and pharmacological research
  5. Medical clinical diagnostics and biomedical research

 

Product Data
  • Temperature Range(℃) : RT+3~55
  • CO2  Range : 0~20%
  • Sterilization : 180°C dry heat
  • Humidity Method : Integrated pan
  • External Size (W×D×H)(mm) : 670×825×920

 

CO2 Incubator Specifications:
Model ICB-170
Temperature Type Direct Heat & Air Jacketed
Range RT+3°C to 55°C
Uniformity ≤±0.3°C
Accuracy <±0.1°C
Recovery ≤10 mins
Ambient 18-34°C
CO2 Controller PID microcomputer
Range 0~20%
Accuracy ±0.1%
Sensor IR
Recovery ≤5 mins
Sterilization 180°C dry heat
Humidity Mode Integrated pan
rH% 91% @ low rH mode, 94% @ High rH mode
Recovery 15 mins
O(Optional Tri-gas Type) Controller PID microcomputer
Range 1~20.7%
Accuracy ±1%
Sensor Zirconia
Accuracy O2% @ 1.0%: 24mins; O2% @ 5.0%: 10mins
Alarm and Reminder Alarms Ambient temp., rH%, CO2%, Water level, O2% (optional)
Reminder HEPA filter expiration, shortage of gas
Cleanliness Sterilization 180°C dryheat
0.2um filter
HEPA filter
Specifications Capacity 170L
Internal Construction Polished stainless steel
Shelf Qty (Standard) 3
Max Shelf Qty Up to 7 optional
Shelf Size (WxD mm) 450×485(Big); 450×440(small)
Max Loading of Each Shelf 12kg
Power Supply AC220V, 50/60Hz
Max. Power 1000W
Stable Power 42W
Internal Size (WxDxH)(mm) 490×560×621
External Size (W×D×H)(mm) 670×825×920
Shipping Size (W×D×H)(mm) 1135×730×965
N.W./G.W. (kg) 94/105

Reviews

There are no reviews yet.

Be the first to review “CO2 Incubator LCD Display”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Incubator LCD Display removeAGD Erma EL-120 ELectrolyte Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeAutomatic Pipette removeiSED Fully Automated ESR Analyzer remove
NameCO2 Incubator LCD Display removeAGD Erma EL-120 ELectrolyte Analyzer removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeAutomatic Pipette removeiSED Fully Automated ESR Analyzer remove
Image
SKUSF1033560130127-23SF1033560084-125SF1033560084-30SF1033560060-2SF1033560084-130SF1033560084-129
Rating
Price

$0.00

$1,320.00

$9.50

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad This CO2 incubator has been specifically designed to provide performance reliability, ease of operation and value for a range of incubation needs, from basic research to demanding cutting-edge applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
CO2 Incubator Features:
For advanced uniformity and recovery, our airflow patterns are specifcally designed for outstanding distribution of critical environmental conditions (temperature, gas exchange and humidity). Forced-air fan gently and evenly distributes clean, humidifed air throughout the chamber ensuring all cells experience the same conditions without the threat of desiccation. Temperature and gas sensors are placed in the chamber to ensure the detected temperature and gas are in the same conditions. Designed for sensitive cells and It is designed to protect valuable samples while optimizing cell growth. 1. 180°C Dry heat sterilization 2. Optional tri-gas 3. Top IR sensor 4. LCD touch screen
 
Applications of CO2 Incubator:
  1. Cell culture and cell growth
  2. Tissue engineering and regenerative medicine research
  3. Cellular virology and bacteriology experiments
  4. Drug screening and pharmacological research
  5. Medical clinical diagnostics and biomedical research
 
Product Data
  • Temperature Range(℃) : RT+3~55
  • CO2  Range : 0~20%
  • Sterilization : 180°C dry heat
  • Humidity Method : Integrated pan
  • External Size (W×D×H)(mm) : 670×825×920
 
CO2 Incubator Specifications:
Model ICB-170
Temperature Type Direct Heat & Air Jacketed
Range RT+3°C to 55°C
Uniformity ≤±0.3°C
Accuracy <±0.1°C
Recovery ≤10 mins
Ambient 18-34°C
CO2 Controller PID microcomputer
Range 0~20%
Accuracy ±0.1%
Sensor IR
Recovery ≤5 mins
Sterilization 180°C dry heat
Humidity Mode Integrated pan
rH% 91% @ low rH mode, 94% @ High rH mode
Recovery 15 mins
O(Optional Tri-gas Type) Controller PID microcomputer
Range 1~20.7%
Accuracy ±1%
Sensor Zirconia
Accuracy O2% @ 1.0%: 24mins; O2% @ 5.0%: 10mins
Alarm and Reminder Alarms Ambient temp., rH%, CO2%, Water level, O2% (optional)
Reminder HEPA filter expiration, shortage of gas
Cleanliness Sterilization 180°C dryheat
0.2um filter
HEPA filter
Specifications Capacity 170L
Internal Construction Polished stainless steel
Shelf Qty (Standard) 3
Max Shelf Qty Up to 7 optional
Shelf Size (WxD mm) 450x485(Big); 450x440(small)
Max Loading of Each Shelf 12kg
Power Supply AC220V, 50/60Hz
Max. Power 1000W
Stable Power 42W
Internal Size (WxDxH)(mm) 490×560×621
External Size (W×D×H)(mm) 670×825×920
Shipping Size (W×D×H)(mm) 1135×730×965
N.W./G.W. (kg) 94/105
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
Twenty Five (25) Test Strip per Packskyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
This Automatic Pipette will help you get your lab up and running in no time—at a great price! Features:
  • Lowest operation and tip ejection forces
  • Fully autoclavable
  • Ultra light weight with space-age materials
  • Secondary adjustment option for various liquid classes
  • Spring loaded tip con
  • For transferring molecular samples and PCR mix solutions.
  • One set is for DNA work and the other for RNA work. Each with the following specs
  • Light weight, traditional tip shaft, and will fit all generic brands of tips
  • Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
  • Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
  • Low maintenance and autoclavable 121° for at least 20 minutes
  • Quick release
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar