CO2 Mainstream Module Capno-M+

$0.00

Shipped From Abroad

An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Kingst

Description

Features of CO2 Mainstream Module Capno-M+
  • Patented Products

With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.

  • High Precision

Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.

  • Suitable For Adults, Children and Newborns

Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.

  • Automatic Pressure Compensation

There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.

  • Reliable Carbon Dioxide OEM Solutions

A variety of protocols, so that your products quickly upgrade assembly.

 

Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 – 40 mmHg ± 2 mmHg

41 – 70 mmHg ± 5% of reading

71 – 100 mmHg ± 8% of reading

101 – 150 mmHg ± 10% of reading

Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products

Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.

  • High Accuracy

It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;

  • Low Consumption and Easy to use

A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;

  • Plug and Play,

No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;

  • Automatic Pressure Compensation

There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;

  • OEM Solution

Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.

Reviews

There are no reviews yet.

Be the first to review “CO2 Mainstream Module Capno-M+”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsCO2 Mainstream Module Capno-M+ removeRender SD-M2000C+ Anesthetic Machine removeRender SD-M2000D Anesthetic Machine removeOxygen Concentrator 3Ltr. removeLab/Ward Coat removeBistos BT-770-12.1" Touchscreen Patient Monitor remove
NameCO2 Mainstream Module Capno-M+ removeRender SD-M2000C+ Anesthetic Machine removeRender SD-M2000D Anesthetic Machine removeOxygen Concentrator 3Ltr. removeLab/Ward Coat removeBistos BT-770-12.1" Touchscreen Patient Monitor remove
ImageBistos BT-770-12.1" Touchscreen Patient Monitor
SKUSF1033560011-11SF1033560011-15SF1033560084-40SF1033560084-222SF1033560059-1
Rating
Price

$0.00

$4,070.00

$5,940.00

$273.00

$11.00

$902.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An original patented product that can be used for both intubated patients and non-intubated patients, breaking through the limitation that mainstream modules can only be used for intubated patients.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of CO2 Mainstream Module Capno-M+
  • Patented Products
With its compact design and two kinds of adapters, the mainstream module can be used for intubated patients and non-intubated patients. Breathing light intuitively and qualitatively reacts to real-time concentration.
  • High Precision
Careful selection of infrared devices, hardware design and software algorithm, to achieve high signal-to-noise ratio and ensure the measurement accuracy within the temperature range of -5-50°C and the measurement range of 0-20%.
  • Suitable For Adults, Children and Newborns
Excellent performance and low cost. Plug and play, the host does not need an internal circuit, but just a serial port. The data can be measured within 4 seconds after power on.
  • Automatic Pressure Compensation
There is an atmospheric pressure sensor inside, which is suitable for various altitude ranges. Built-in interference gas compensation algorithm.
  • Reliable Carbon Dioxide OEM Solutions
A variety of protocols, so that your products quickly upgrade assembly.  
Specifications of CO2 Mainstream Module Capno-M+
Technique Non-dispersive infrared gas analysis, multi-channel infrared detector, no moving parts
Storage condition -40°C to 70°C,<93% RH, non-condensing
Working condition 5 to 40℃,10 to 90% RH, non-condensing
Circumstance pressure 55-115kP
Power demand 5V ± 5% (max ripple 200 mVp-p)
Power consumption <150mA
lnterface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customized communication protocol.
CO2 measurement range 0-150 mmHg, 0-20 kPa, 0-19.7%
CO2 resolution 0.1mmHg
co2 measurement accuracy 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading
Respiration rate 3-150 bpm
Respiration rate accuracy ±1% of reading or ±1 rpm whichever is greater
Anesthetic gas compensation N2O, O2, Agent (HOST supplied)
Barometric Pressure Barometric Pressure 400 to 860 mm Hg automatic
Warm-up time To reach designed deviation 97% within 8s, to reach designed deviation within 20s.
Rise time About 70ms
CO2 Stability Shortly drifting: drifting less than 1 mmHg, after 4 hours’ power on. Long drifting: drifting does not influence nominal accuracy after continu hous 140 hours’power on
Calibration No routine user calibration required
Zero proceeding when replacing adaptor
EtCO2 calcualtion every breath, or 10 or 20 seconds averagely
Application Scenarios of CO2 Mainstream Module Capno-M+
  • Innovative Patented Products
Capno-M+ is an innovative carbon dioxide module independently developed by Kingst, which can be used for both intubated and non-intubated patients. It breaks through the limit that the mainstream modules can only be used for intubated patients in the past.
  • High Accuracy
It is equipped with a high-quality Infrared device, hardware design, and software algorithm to achieve gas concentration measurement with a high signal-to-noise ratio;
  • Low Consumption and Easy to use
A variety of adapters for adults, children and newborns, cost-effective, reduce the cost of use;
  • Plug and Play,
No circuit is required inside the host, only one serial port is needed, and the data can be measured within 4 seconds after power-on;
  • Automatic Pressure Compensation
There is an internal atmospheric pressure sensor, suitable for various altitude ranges, and a built-in interference gas compensation algorithm;
  • OEM Solution
Reliable CO2 OEM solution, compatible with multiple protocols, enabling you to quickly upgrade your product.
  • 5.5" monochrome TFT LCD screen
  • Built in Anesthesia ventilator
  • Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
  • Updated high brightness LED lamp
  • Compact CO2 absorber (autoclavable)
  • Optional: Continuous FIO2 monitoring
  • Optional: Anaesthesia gas scavenging system
  • Optional: Yoke system for 5L O2/N2O cylinders
  • Optional: Integrated suction unit on air
 
Click Here To Download Catalogue
   
 
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare