Combined Pharmacy Refrigerator and Freezer

$0.00

Shipped From Abroad

This product is designed to store frozen plasma, biomaterials, vaccines, electronic devices and low temperature tests of special materials, in blood stations, hospitals, epidemic prevention stations, universities, scientific research institutes, electronic chemical industry and other enterprise laboratories.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130125-22

Description

Product Features

Temperature Control

● Refrigerator temperature ranges from 2°C to 8°C.

● Freezer temperature ranges adjustable from -10°C to -40 °C.

● Microprocessor temperature control accuracy 0.1°C (refrigerator) and 1°C (freezer) .

Safety

● Separate doors for refrigerator and freezer with independent lock catches, dual padlocks available to ensure product safety.

● Multiple alarm functions including high or low temperature, sensor error, high ambient temp, power failure and remote alarm.

● Two types of alarm indications: audible buzzer and visible flashing light.

Refrigerator System

● Refrigerator and freezer have independently controlled variable frequency refrigeration systems, standalone displays as well as separate on and off controls.

● Robust compressor system operating with environmentally friendly hydrocarbon refrigerant.

● Refrigerator with high quality and high efficiency cooling fan provides better temperature uniformity and stability.

Ergonomic Design

● Large LED screen display for excellent user interface experience.

● USB port automatically saves temperature data for up to 10 years for convenient inquiry and record keeping.

● Optional printer to simultaneously print out temperatures of the refrigerator and the freezer.

● Four casters and two levelling legs design for ease of maneuvering.

 

Specifications
Model Cabinet Type Capacity (L/Cu.Ft) Power Supply (V/Hz) Display Shelves Temperature
HYCD-319A Upright;Refrigerator | Freezer 200/7.06 | 100/3.53 115/60 LED 3 | 1 2~8 | -15~-40
HYCD-469 Upright;Refrigerator | Freezer 269/9.5 | 200/7.1 220~240/50/60 LED 3 2~8 | -10~-40
HYCD-469A Upright;Refrigerator | Freezer 269/9.5 | 200/7.1 220~240/50/60 LED 3 2~8 | -10~-40
HYCD-282 Upright;Refrigerator | Freezer 185/6.5 | 97/3.4 220~240/50/60 LED 3 | 1 2~8 | -10~-40
HYCD-282A Upright;Refrigerator | Freezer 185/6.5 | 97/3.4 220~240/50/60 LED 3 | 1 2~8 | -10~-40

 

Click here to download Catalogue

 

Reviews

There are no reviews yet.

Be the first to review “Combined Pharmacy Refrigerator and Freezer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Combined Pharmacy Refrigerator and Freezer removeSkyla Hi POC Clinical Chemistry Analyzer removePlastic Urine Container Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter remove
NameCombined Pharmacy Refrigerator and Freezer removeSkyla Hi POC Clinical Chemistry Analyzer removePlastic Urine Container Per Pack removeDiscover 14 Panel Cup with Adulterants Per Pack remove8 Bucket Centrifuge removeErma B-111 Bilirubin Meter remove
ImageDrug Test Cup
SKUSF1033560130125-22SF1033560060-2SF1033560084-106SF1033560084-28SF1033560084-114SF1033560084-6
Rating
Price

$0.00

$0.00

$8.20

$0.00

$72.50

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad This product is designed to store frozen plasma, biomaterials, vaccines, electronic devices and low temperature tests of special materials, in blood stations, hospitals, epidemic prevention stations, universities, scientific research institutes, electronic chemical industry and other enterprise laboratories.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Features

Temperature Control

● Refrigerator temperature ranges from 2°C to 8°C. ● Freezer temperature ranges adjustable from -10°C to -40 °C. ● Microprocessor temperature control accuracy 0.1°C (refrigerator) and 1°C (freezer) .

Safety

● Separate doors for refrigerator and freezer with independent lock catches, dual padlocks available to ensure product safety. ● Multiple alarm functions including high or low temperature, sensor error, high ambient temp, power failure and remote alarm. ● Two types of alarm indications: audible buzzer and visible flashing light.

Refrigerator System

● Refrigerator and freezer have independently controlled variable frequency refrigeration systems, standalone displays as well as separate on and off controls. ● Robust compressor system operating with environmentally friendly hydrocarbon refrigerant. ● Refrigerator with high quality and high efficiency cooling fan provides better temperature uniformity and stability.

Ergonomic Design

● Large LED screen display for excellent user interface experience. ● USB port automatically saves temperature data for up to 10 years for convenient inquiry and record keeping. ● Optional printer to simultaneously print out temperatures of the refrigerator and the freezer. ● Four casters and two levelling legs design for ease of maneuvering.  
Specifications
Model Cabinet Type Capacity (L/Cu.Ft) Power Supply (V/Hz) Display Shelves Temperature
HYCD-319A Upright;Refrigerator | Freezer 200/7.06 | 100/3.53 115/60 LED 3 | 1 2~8 | -15~-40
HYCD-469 Upright;Refrigerator | Freezer 269/9.5 | 200/7.1 220~240/50/60 LED 3 2~8 | -10~-40
HYCD-469A Upright;Refrigerator | Freezer 269/9.5 | 200/7.1 220~240/50/60 LED 3 2~8 | -10~-40
HYCD-282 Upright;Refrigerator | Freezer 185/6.5 | 97/3.4 220~240/50/60 LED 3 | 1 2~8 | -10~-40
HYCD-282A Upright;Refrigerator | Freezer 185/6.5 | 97/3.4 220~240/50/60 LED 3 | 1 2~8 | -10~-40
 
Click here to download Catalogue
 
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare