Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized
Delivery & Availability:
Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.
Features:
Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.
Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.
Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.
Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.
Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.
Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge
Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)
Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Click Here To Download Catalogue
Quick Comparison
Settings | CU Medical Plasma Sterilizer HPS-100 remove | Discover 5 Panel Cup with Adulterants Per Pack remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Plastic Urine Container Per Pack remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Erma B-111 Bilirubin Meter remove | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | CU Medical Plasma Sterilizer HPS-100 remove | Discover 5 Panel Cup with Adulterants Per Pack remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Plastic Urine Container Per Pack remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Erma B-111 Bilirubin Meter remove | ||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||
SKU | SF10335601245 | SF1033560084-23 | SF1033560060-2 | SF1033560084-106 | SF1033560084-125 | SF1033560084-6 | ||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||
Price |
|
|
| $8.20 | $1,320.00 | $715.00 | ||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized Delivery & Availability: Typically 14-21 Working Days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant.
Delivery & Availability:
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped From Abroad
| Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||
Content | Medium & Large 100L sterilizers Recommended for Small & Medium Medical Hospitals, Community Healthcare Centers, Military Hospitals and big surgical instruments can be sterilized.
Features:
Easy to install
Simply plug into a standard 220v outlet and your HPS series sterilizers are ready to go. You won’t need additional facilities such as compressed air, drainage system, ventilation system.
Easy to use
You can start/cancel/control the sterilization process by simply pushing key buttons. The selected sterilization cycle will be progressed automatically and you can monitor relevant information such as sterilization conditions, progress status, error messages from the display.
Automatic notification system for regular maintenance
Your HPS series sterilizer will automatically notify you the replacement period of consumables such as pump oil, air filter and so on. After 250 cycles of sterilization, a warning message to change oil will be displayed and your sterilizer will stop working when reaches 300 cycles without change of oil to prevent equipment failure.
Self-Test Features
When malfunction occurs during operation, an error code is displayed by self-test features and the running sterilization cycle is interrupted automatically for safety.
Validation of Sterilization of HPS?100
A PCD(Process Challenge Device) in accordance with EU standards(EN 867-5) is used for the validation of sterilization of HPS-100 series sterilizers at the most difficult positions inside of the sterilization load so that the most challenging medical instruments including dead-end lumens can be sterilized efficiently and effectively. tem, ventilation system.
Specifications
Sterilizing Agent: Hydrogen Peroxide, 1 Cycle/Cartridge
Total Cycle Time :
1) Smart Mode – 40min
2) Standard Mode – 48min
3) Special Mode – 56min
Cycle Temperature : 45? ~ 60?
SAL(Sterility Assurance Level) : 10-6(Bacillus)
Material – Aluminum
Volume -100L
Dimensions : Overall – 700mm(W)×1610mm(H)×954mm(D), Chamber – 400mm(W)×358mm(H)×750mm(D)
Weight : 180?
Control : 32bit Micro Processor
Cycle Information : 2.7″(OLED) Display, Printer
Electrical : AC 220-230V~, 50/60Hz
Power Consumption : Max 3.4kw
Installation Requirements : Front – 100cm, Rear, Left side, Right side : 5cm
Placement : Bult-in wheels provide mobility
Room Conditions : Use Environment 10~40?, 30~75%RH, Installation Environment -20~60?, 0~95%RH
Printer : Built-in Thermal Printer(Brief Mode/Detail Mode) Cycle Parameters(Temp, Pressure, Time, Daily&Total Cycle, etc)
Click Here To Download Catalogue |
All-in-One Design
| skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
|
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| ||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.