DISTRIBUTED ATMOSPHERE MONITORING SYSTEM
$0.00
Shipped From Abroad
Key Features
- Optional Submarine PMS (Platform Management System) integration
- Customized user interface/HMI
- Datalogging
- Download port
- Visual alarms with alarm location
- Password protection
- Choice of gas sensing modules: oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), hydrogen (H2) and refrigerants
- Local visual alarms
- Optional relays
- Temperature compensated
- User maintainable
- Partial pressure sensing
- MIL-STD-461F compliant
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Description
The DAMS (Distributed Atmosphere Monitoring System) is a flexible, robust and fully configurable, submarine atmosphere monitoring system.
Designed with you in mind, this life-saving, mission critical equipment offers multi-point sensing for AIP or Diesel Electric subs and is suitable for new submarine designs or mid-life upgrades.
Gas sensors are monitored centrally via the PLC and offer local sensing and alerts for the crew in the aft, middle and fore of your boat, giving you true peace of mind throughout the duration of your patrol.
Technical Specification
DAMS SPECIFICATION
Characteristics
Flexibility
No matter a submarine’s size or what country’s flag it flies, it is a fact that no two submarines are the same. Every vessel has unique gas monitoring needs and requires an analytical tool with the versatility to be configured to each vessel’s individual requirements. Each state-of-art DAMS unit is flexible, robust and fully configurable and can monitor up to six different gasses simultaneously from one centralized PLC (programmable logic controller) panel.
Communication
Easily the most versatile and customizable product in the entire Analox line, DAMS quite simply is a centralized hub that allows multiple analyzers and monitors located in multiple locations throughout a submarine to communicate with each other. With the integral communication to the ships platform management systems, should an alarm be triggered, the duty officer is ideally positioned and instantly informed to take appropriate corrective action without having to leave the Con, or central control room.
Testing
The modular design of the DAMS incorporates multiple testing technologies including GFC to monitor carbon monoxide (CO), electrochemical for depleted or enriched oxygen (O2), NDIR for carbon dioxide (CO2) and refrigerants (R134a) and Catalytic Bead technology to test for hydrogen (H2). Each DAMS monitor is ideally suited for conventionally powered diesel/electric powered submarines or air-independent propulsion (AIP) designs.
Each DAMS unit is shock, pressure and temperature compensated and tested to withstand the demanding submarine environment. This highly versatile tool can be tailored to customer-specific requirements for EMC (electro-magnetic capability), durability, vibration and noise interference.
Having successfully passed rigorous sea trials and laboratory testing, DAMS units are currently deployed with multiple naval groups throughout the world. In response to highly precise military standards and requirements, DAMS is simple to customize and install. Each unit is user maintainable, and has delivered the proven accuracy and reliability demanded by the submarine community. The modular design of DAMS allows for upgrades and changes to the system as the vessel’s operational requirements change throughout the product’s operational life.
Easy Calibration
Each DAMS system can be calibrated by just one person and is extremely easy to maintain, reducing and often eliminating disruptions to normal operations. Analox also offers multi-gas sensors that can be calibrated simultaneously.
Click here to download Data Sheet
Quick Comparison
Settings | DISTRIBUTED ATMOSPHERE MONITORING SYSTEM remove | OXYGEN & CARBON DIOXIDE MONITOR remove | VENUS SOLO OEM SENSOR remove | PERSONAL CO2/O2 MONITOR-SUB-ASPIDA remove | CARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM remove | Pilot-RO Water Purification System remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | DISTRIBUTED ATMOSPHERE MONITORING SYSTEM remove | OXYGEN & CARBON DIOXIDE MONITOR remove | VENUS SOLO OEM SENSOR remove | PERSONAL CO2/O2 MONITOR-SUB-ASPIDA remove | CARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM remove | Pilot-RO Water Purification System remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130141-14 | SF1033560130141-12 | SF1033560130141-15 | SF1033560130141-13 | SF1033560130141-2 | SF1033560130126-2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Key Features
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Key Features
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Key Features
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Key features
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The COSAMS unit was designed specifically for use on submarines, most directly those that operate on diesel engines. Built to exacting military standards for performance, reliability and endurance, the Analox COSAMS uses proprietary Gas Filter Correlation (GFC) technology to specifically analyze the unique properties of CO. The COSAMS (Carbon Monoxide Submarine Atmosphere Monitoring System) has been designed for use on submerged submarines to support life, where crew can be living and working for up to 90 days. Carbon monoxide can be generated on a submarine in several ways, from cooking and fire, to the incomplete combustion of diesel fuel and chlorate candles.Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | DescriptionThe DAMS (Distributed Atmosphere Monitoring System) is a flexible, robust and fully configurable, submarine atmosphere monitoring system. Designed with you in mind, this life-saving, mission critical equipment offers multi-point sensing for AIP or Diesel Electric subs and is suitable for new submarine designs or mid-life upgrades.Gas sensors are monitored centrally via the PLC and offer local sensing and alerts for the crew in the aft, middle and fore of your boat, giving you true peace of mind throughout the duration of your patrol. Technical SpecificationDAMS SPECIFICATIONCharacteristicsFlexibility No matter a submarine’s size or what country’s flag it flies, it is a fact that no two submarines are the same. Every vessel has unique gas monitoring needs and requires an analytical tool with the versatility to be configured to each vessel’s individual requirements. Each state-of-art DAMS unit is flexible, robust and fully configurable and can monitor up to six different gasses simultaneously from one centralized PLC (programmable logic controller) panel.Communication Easily the most versatile and customizable product in the entire Analox line, DAMS quite simply is a centralized hub that allows multiple analyzers and monitors located in multiple locations throughout a submarine to communicate with each other. With the integral communication to the ships platform management systems, should an alarm be triggered, the duty officer is ideally positioned and instantly informed to take appropriate corrective action without having to leave the Con, or central control room. Testing The modular design of the DAMS incorporates multiple testing technologies including GFC to monitor carbon monoxide (CO), electrochemical for depleted or enriched oxygen (O2), NDIR for carbon dioxide (CO2) and refrigerants (R134a) and Catalytic Bead technology to test for hydrogen (H2). Each DAMS monitor is ideally suited for conventionally powered diesel/electric powered submarines or air-independent propulsion (AIP) designs. Each DAMS unit is shock, pressure and temperature compensated and tested to withstand the demanding submarine environment. This highly versatile tool can be tailored to customer-specific requirements for EMC (electro-magnetic capability), durability, vibration and noise interference. Having successfully passed rigorous sea trials and laboratory testing, DAMS units are currently deployed with multiple naval groups throughout the world. In response to highly precise military standards and requirements, DAMS is simple to customize and install. Each unit is user maintainable, and has delivered the proven accuracy and reliability demanded by the submarine community. The modular design of DAMS allows for upgrades and changes to the system as the vessel’s operational requirements change throughout the product’s operational life.Easy Calibration Each DAMS system can be calibrated by just one person and is extremely easy to maintain, reducing and often eliminating disruptions to normal operations. Analox also offers multi-gas sensors that can be calibrated simultaneously.Click here to download Data Sheet | DescriptionThe SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.Technical SpecificationSV-Multigas-2 | DescriptionThe Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure. Technical SpecificationVenus Solo | DescriptionThe Sub Aspida is a personal, portable monitor which is used to detect levels of carbon dioxide (CO2) and oxygen (O2) in pressurized environments.CO2 monitoring & O2 monitoring with the Sub AspidaUnlike industrial sensing monitors, the Sub Aspida was designed with pressure corrected sensors, giving you 100% confidence in your readings. The Sub Aspida has been upgraded to support those who work at high altitude. Pressure tested to 10,000 ft or 700 MB, the Sub Aspida will remain accurate and reliable when monitoring CO2 and O2 in the atmosphere, meaning you can concentrate on the job at hand!Technical SpecificationSUB-ASPIDA | Key Features
Technical SpecificationsClick here to download Data SheetClick here to download Manual | An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Reviews
There are no reviews yet.