DISTRIBUTED ATMOSPHERE MONITORING SYSTEM

$0.00

Shipped From Abroad

Key Features
  • Optional Submarine PMS (Platform Management System) integration
  • Customized user interface/HMI
  • Datalogging
  • Download port
  • Visual alarms with alarm location
  • Password protection
  • Choice of gas sensing modules: oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), hydrogen (H2) and refrigerants
  • Local visual alarms
  • Optional relays
  • Temperature compensated
  • User maintainable
  • Partial pressure sensing
  • MIL-STD-461F compliant
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130141-14
Brands:: Analox

Description

Description

The DAMS (Distributed Atmosphere Monitoring System) is a flexible, robust and fully configurable, submarine atmosphere monitoring system.

Designed with you in mind, this life-saving, mission critical equipment offers multi-point sensing for AIP or Diesel Electric subs and is suitable for new submarine designs or mid-life upgrades.

Gas sensors are monitored centrally via the PLC and offer local sensing and alerts for the crew in the aft, middle and fore of your boat, giving you true peace of mind throughout the duration of your patrol.

 

Technical Specification

DAMS SPECIFICATION

 

Characteristics

Flexibility

No matter a submarine’s size or what country’s flag it flies, it is a fact that no two submarines are the same. Every vessel has unique gas monitoring needs and requires an analytical tool with the versatility to be configured to each vessel’s individual requirements. Each state-of-art DAMS unit is flexible, robust and fully configurable and can monitor up to six different gasses simultaneously from one centralized PLC (programmable logic controller) panel.

 

Communication

Easily the most versatile and customizable product in the entire Analox line, DAMS quite simply is a centralized hub that allows multiple analyzers and monitors located in multiple locations throughout a submarine to communicate with each other. With the integral communication to the ships platform management systems, should an alarm be triggered, the duty officer is ideally positioned and instantly informed to take appropriate corrective action without having to leave the Con, or central control room.

 

Testing

The modular design of the DAMS incorporates multiple testing technologies including GFC to monitor carbon monoxide (CO), electrochemical for depleted or enriched oxygen (O2), NDIR for carbon dioxide (CO2) and refrigerants (R134a) and Catalytic Bead technology to test for hydrogen (H2). Each DAMS monitor is ideally suited for conventionally powered diesel/electric powered submarines or air-independent propulsion (AIP) designs.

Each DAMS unit is shock, pressure and temperature compensated and tested to withstand the demanding submarine environment. This highly versatile tool can be tailored to customer-specific requirements for EMC (electro-magnetic capability), durability, vibration and noise interference.

Having successfully passed rigorous sea trials and laboratory testing, DAMS units are currently deployed with multiple naval groups throughout the world. In response to highly precise military standards and requirements, DAMS is simple to customize and install. Each unit is user maintainable, and has delivered the proven accuracy and reliability demanded by the submarine community. The modular design of DAMS allows for upgrades and changes to the system as the vessel’s operational requirements change throughout the product’s operational life.

Easy Calibration

Each DAMS system can be calibrated by just one person and is extremely easy to maintain, reducing and often eliminating disruptions to normal operations. Analox also offers multi-gas sensors that can be calibrated simultaneously.

Click here to download Data Sheet

Reviews

There are no reviews yet.

Be the first to review “DISTRIBUTED ATMOSPHERE MONITORING SYSTEM”

Your email address will not be published. Required fields are marked *

Quick Comparison

DISTRIBUTED ATMOSPHERE MONITORING SYSTEM removePilot-RO Water Purification System removeOXYGEN & CARBON DIOXIDE MONITOR removeVENUS SOLO OEM SENSOR removeCOMPRESSED BREATHING AIR MONITOR removeAx60+ Kiosk remove
NameDISTRIBUTED ATMOSPHERE MONITORING SYSTEM removePilot-RO Water Purification System removeOXYGEN & CARBON DIOXIDE MONITOR removeVENUS SOLO OEM SENSOR removeCOMPRESSED BREATHING AIR MONITOR removeAx60+ Kiosk remove
Image
SKUSF1033560130141-14SF1033560130126-2SF1033560130141-12SF1033560130141-15SF1033560130141-3SF1033560130141-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Key Features
  • Optional Submarine PMS (Platform Management System) integration
  • Customized user interface/HMI
  • Datalogging
  • Download port
  • Visual alarms with alarm location
  • Password protection
  • Choice of gas sensing modules: oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), hydrogen (H2) and refrigerants
  • Local visual alarms
  • Optional relays
  • Temperature compensated
  • User maintainable
  • Partial pressure sensing
  • MIL-STD-461F compliant
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Single gas (user defined)
  • Backward compatible with ADC’s ‘Eclipse’
  • Linearised Output
  • Continuous status signal to check device health
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Provides continuous monitoring 24/7
  • Low maintenance and is easy to install and maintain
  • Provides 90 days of datalogging which you can easily retrieve via a USB connection
  • Cost effective alternative to colorimetric tube testing
  • Supplied as either a fixed or portable version depending upon your needs
  • Can be used on any breathing air compressor
  • Digital display
 
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Low maintenance
  • Quick Connect System
  • Pre-wired, ready to go
  • Can support up to 4 alarm units
  • Push button for unit testing
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
The DAMS (Distributed Atmosphere Monitoring System) is a flexible, robust and fully configurable, submarine atmosphere monitoring system. Designed with you in mind, this life-saving, mission critical equipment offers multi-point sensing for AIP or Diesel Electric subs and is suitable for new submarine designs or mid-life upgrades.

Gas sensors are monitored centrally via the PLC and offer local sensing and alerts for the crew in the aft, middle and fore of your boat, giving you true peace of mind throughout the duration of your patrol.

 
Technical Specification
DAMS SPECIFICATION  
Characteristics

Flexibility

No matter a submarine’s size or what country’s flag it flies, it is a fact that no two submarines are the same. Every vessel has unique gas monitoring needs and requires an analytical tool with the versatility to be configured to each vessel’s individual requirements. Each state-of-art DAMS unit is flexible, robust and fully configurable and can monitor up to six different gasses simultaneously from one centralized PLC (programmable logic controller) panel.  

Communication

Easily the most versatile and customizable product in the entire Analox line, DAMS quite simply is a centralized hub that allows multiple analyzers and monitors located in multiple locations throughout a submarine to communicate with each other. With the integral communication to the ships platform management systems, should an alarm be triggered, the duty officer is ideally positioned and instantly informed to take appropriate corrective action without having to leave the Con, or central control room.

 

Testing

The modular design of the DAMS incorporates multiple testing technologies including GFC to monitor carbon monoxide (CO), electrochemical for depleted or enriched oxygen (O2), NDIR for carbon dioxide (CO2) and refrigerants (R134a) and Catalytic Bead technology to test for hydrogen (H2). Each DAMS monitor is ideally suited for conventionally powered diesel/electric powered submarines or air-independent propulsion (AIP) designs.

Each DAMS unit is shock, pressure and temperature compensated and tested to withstand the demanding submarine environment. This highly versatile tool can be tailored to customer-specific requirements for EMC (electro-magnetic capability), durability, vibration and noise interference. Having successfully passed rigorous sea trials and laboratory testing, DAMS units are currently deployed with multiple naval groups throughout the world. In response to highly precise military standards and requirements, DAMS is simple to customize and install. Each unit is user maintainable, and has delivered the proven accuracy and reliability demanded by the submarine community. The modular design of DAMS allows for upgrades and changes to the system as the vessel’s operational requirements change throughout the product’s operational life.

Easy Calibration

Each DAMS system can be calibrated by just one person and is extremely easy to maintain, reducing and often eliminating disruptions to normal operations. Analox also offers multi-gas sensors that can be calibrated simultaneously.
Click here to download Data Sheet
An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
Description
The Venus Solo OEM sensor is a self-contained unit designed for integration into other manufacturers’ equipment and provides a measurement of gas concentration according to specific user requirements. These GFC (Gas Filter Correlation) sensors generate a signal proportional to the infrared absorption of the measured gas. Providing the gas concentration lies within the designed range of the sensor, the signal is periodically compared with a reference gas. Gas concentrations are indicated through the non-linearised analogue signal output. Gas connections to and from the sensor are via suitable fittings on the gas measuring cell. The Venus Solo OEM Series sensors electrical supply is designed to accept 24V DC (3amp max). Our Venus Solo OEM sensor uses GFC (Gas Filter Correlation) technology to give highly accurate gas measurements. The Venus Solo can be integrated into your own gas analyzer or management system and offers the user a 0-2.5v analogue output.

The sensor is currently available as either: Carbon dioxide (CO2), carbon monoxide (CO), nitrous oxide (N20), methane (CH4) or nitric oxide (NO). If your application requires a different gas, just let us know and we can customise it to your needs. The Venus Solo is used in Military applications to protect submariners from carbon monoxide (CO) exposure.  

Technical Specification
Venus Solo
A Reliable Tool
The ACG+ offers continuous monitoring of up to five different gas variables (oxygen, carbon monoxide, carbon dioxide, volatile organic compounds and water vapor) and simultaneously displays results for testing and calibration purposes. This eliminates potential delays and downtimes while test results are sent out for analysis. The ACG+ has also made cumbersome colorimetric tubes obsolete by drastically reducing the potential for human error in gas analysis. The continuous monitoring also has virtually eliminated the need for time-consuming spot checks. The ACG+ simultaneously scans for O2, CO2, CO, VOCs and water vapor, making it one of the most versatile tools any vessel can utilize. The automatic data log provides additional peace of mind for decision makers.  
A Cost Effective Solution
You can’t put a price on safety, reliability and peace of mind. The Analox development team created the ACG+ to combine multiple tasks simultaneously, reducing the need for multiple analyzer units, costly test tubes, and often, extended times in port for repairs. The ACG+ is available in either a fixed location model or convenient portable units. This adaptability provides designers, procurement officers and equipment specialists some options in closed quarter situations.  
A Tool, Easy To Install And Maintain
While each ACG+ unit can monitor up to five gasses simultaneously, each analytical system operating in the ACG+ is independent of the others. This means sensors can be replaced individually without needlessly causing downtime.  
An Easy Choice

The Analox ACG+ has been proven effective in military situations around the world. The unit’s continuous and specific monitoring capabilities make it an easy choice for key decision-makers.

 
Technical Specifications
ACG+
Power 24V DC
Optional battery power NiMH or Li-ION
Optional mains adaptor Universal input 95 to 250 V AC, 50/60 Hz
IP Rating IP45
Response Time T90 <120 seconds T90 <15 minutes H2O sensor
Temperature Operating: −5 °C to 50 °C / 23°F to 122°F Storage: −10 °C to 60°C / 14°F to 140°F
Flow rate 0.5L per minute (max)
Inlet Pressure 5-10 Bar Gauge (Optional regulator can be purchased)
Humidity 0-99% RH (Non Condensing)
Outputs 1 x normally open relay contacts 1 x normally closed relay contacts 3 x 24 V DC switched output
ACG+ Sensors
O2 Sensor CO2 Sensor CO Sensor VOC Sensor Water Vapor Sensor
Range 0 to 50% 0 to 1000 ppm 0 to 20 ppm 0 to 100 ppm 0 to 100 mg/m3
Accuracy ±(0.035% O2 + 1% of reading + ±(0.035% O2 + 1% of reading + 0.15% of reading/°C) ±(25 ppm CO2 + 1% of reading + 1 ppm CO2/°C) ±(1 ppm CO + 5% of reading + 0.1 ppm CO/°C) ±(1 ppm VOC + 5% of reading + 0.25% of reading/°C) ±(0.15 mg/m3 H2O + 20% of reading)
Technology Analox MEC intelligent electrochemical oxygen sensor Analox 5S3 intelligent NDIR sensor Analox MEC intelligent electrochemical sensor Analox MEC intelligent PID sensor Water vapour sensor using capacitive technology
Click here to download Data Sheet
Click here to download Quick Start Guide
Click here to download User Manual
CO2 MONITOR & ALARM DESIGNED FOR KIOSKS

The Ax60+ Kiosk is a CO2 monitor and alarm specifically designed by Analox to alert personnel to a build up/leak of CO2 using a state-of-the-art infrared sensor. The alarm provides both audio and visual alerts in the case of increased levels of carbon dioxide (CO2). Up to four alarms can be added as needed and the unit does not need periodic calibration.

CO2 monitoring with the AX60+ Kiosk
The Ax60+ Kiosk is a smaller version of the popular Ax60+ carbon dioxide (CO2) monitor. It is simple to wall mount in the area where carbon dioxide (CO2) is stored or piped. The Ax60+ Kiosk sensor needs to be installed at a height of 12-18 inches (305-457mm) above the floor – this is because the carbon dioxide (CO2) that leaks from a gas cylinder is denser than ambient air and can collect at low levels. The alarm should be located above the sensor at about head height or at the entrance to the kiosk.  
Technical Specification
Sensor Unit
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare