DynaMesh-PRP soft
$0.00
Shipped From Abroad
DynaMesh®-PRP soft and DynaMesh®-PRP visible implants are intended to be used as bridging material and reinforce soft tissue as part of surgical treatment for apical pelvic organ prolapse.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Pectopexy
Bilateral Fixation on the Pectineal Ligament
Fig. left:
Apical mesh repair following hysterectomy with DynaMesh®-PRP soft / visible (03 cm x 15 cm)

Pectopexy after vaginal/cervical stump prolapse:
- Two implant sizes are available in the following dimensions DynaMesh®-PRP soft / visible 03 cm x 15 cm and DynaMesh®-PRP visible 03 cm x 18 cm.
- With greatly shortened vaginas, e.g., following a radical hysterectomy, DynaMesh®-PRP visible 03 cm x 18 cm can be used.

Pectopexy after vaginal/cervical stump prolapse with concomitant cystocele and/or rectocele: (pulsion cystocele / rectocele)
- Additional stabilisation of the anterior and/or posterior vaginal wall can be achieved with DynaMesh®-PRP visible 17 cm x 15 cm.

Pectopexy after uterine prolapse with uterine preservation:
- With a normal sized uterus, DynaMesh®-PRP visible 03 cm x 18 cm can be used and fixed in place on the posterior cervix.

Pectopexy after uterine prolapse with uterine preservation:
- With smaller uteri (below 100 g), anterior fixation of DynaMesh®-PRP soft / visible 03 cm x 15 cm can be selected as an alternative.
Specifications
| Product | DynaMesh®-PRP soft 03 cm x 15 cm (1) DynaMesh®-PRP visible 03 cm x 15 cm (2) DynaMesh®-PRP visible 03 cm x 18 cm (3) DynaMesh®-PRP visible 17 cm x 15 cm (4) |
| Surgical Treatment | Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump) |
| Surgical Approach | Minimally Invasive / Open |
| Surgical Technique | Pectopexy (1) – (3) / Pectopexy with reinforcement of the vaginal walls in case of concomitant cystocele and/or rectocele.(4) |
| Fixation | – Pectineal ligament: non-absorbable suture – Vaginal stump: absorbable monofilament suture – Cervix: non-absorbable suture (size 0) |
| Smooth Warp-Knitted Selvedges | |
| Defined Elasticity | |
| Visible Technology | |
| Materials |
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (4)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (4) – Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) – (4) |
| Polymer (Monofilament) | PVDF |
| Biocompatibility | |
| Ageing Resistance | |
| Effective Porosity | |
| Klinge’s Mesh Classification | Class 1a [102P, TR121] |
Quick Comparison
| DynaMesh-PRP soft remove | Oxygen Concentrator 3Ltr. remove | Portable Stainless Steel Autoclave Sterilizer remove | McKesson Sprague Rappaport Stethoscope remove | Bettermed BT667E Electric Operating Table remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | |||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | DynaMesh-PRP soft remove | Oxygen Concentrator 3Ltr. remove | Portable Stainless Steel Autoclave Sterilizer remove | McKesson Sprague Rappaport Stethoscope remove | Bettermed BT667E Electric Operating Table remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | ||||||||||||||||||||||||||||||||||||||||
| Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||
| SKU | SF1033560130161-10 | SF1033560084-40 | SF1033560084-4 | SF1033560084-35 | SF1033560084-50 | SF1033560059-1 | ||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||
| Price |
| $273.00 | $216.00 | $17.00 | $2,178.00 | $902.00 | ||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
DynaMesh®-PRP soft and DynaMesh®-PRP visible implants are intended to be used as bridging material and reinforce soft tissue as part of surgical treatment for apical pelvic organ prolapse.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In Stock
| In Stock
McKesson Sprague Rappaport Stethoscope: The McKesson Brand Two Sided Classic Nurse Stethoscope is an invaluable Diagnostic Instrument used by medical professionals when diagnosing heart, lung and vascular conditions. This high-quality stethoscope features an adjustable aluminum binaural, a single lumen 22-inch tube, a two-sided wide frequency chest piece, and comfortable ear tips.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
This operation table is used for the surgeries of chest ,abdomen ,ophthalmology,obstetrics,and urology.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||
| Content |
| Product | DynaMesh®-PRP soft 03 cm x 15 cm (1) DynaMesh®-PRP visible 03 cm x 15 cm (2) DynaMesh®-PRP visible 03 cm x 18 cm (3) DynaMesh®-PRP visible 17 cm x 15 cm (4) |
| Surgical Treatment | Apical Pelvic Organ Prolapse (Uterus / Vaginal Stump / Cervical Stump) |
| Surgical Approach | Minimally Invasive / Open |
| Surgical Technique | Pectopexy (1) – (3) / Pectopexy with reinforcement of the vaginal walls in case of concomitant cystocele and/or rectocele.(4) |
| Fixation | – Pectineal ligament: non-absorbable suture – Vaginal stump: absorbable monofilament suture – Cervix: non-absorbable suture (size 0) |
| Smooth Warp-Knitted Selvedges | |
| Defined Elasticity | |
| Visible Technology | |
| Materials |
– Polyvinylidene fluoride (PVDF) (CAS 24937-79-9) > 99% (w/w) (1) – (4)
– Phthalocyanine green (CAS 1328-53-6) < 1% (w/w) (1) – (4)
– Triiron tetraoxide (CAS 1317-61-9) < 1% (w/w) (2) – (4) |
| Polymer (Monofilament) | PVDF |
| Biocompatibility | |
| Ageing Resistance | |
| Effective Porosity | |
| Klinge’s Mesh Classification | Class 1a [102P, TR121] |
-
- .
- Can be set as required sterilization temperature, working tem. range:room tem.:+5~126 Degree.
- Can ge set as required sterilization time of heat preservation, setting range:1~99min.
- Having a low water to stop heating function.
- This product uses the high quality stainless steel SUS304. Having to work under normal conditions adequate safety strength.
| Model No.: | YX280A |
| Sterilizing volume | 18L |
| Working pressure | 0.14-0.16Mpa |
| Working temperature | 126ºC |
| Max. safety pressure | 0.165Mpa |
| Characteristics | Electric heated |
- McKesson Dual-Head Scope – Black
- Lightweight combination diaphragm/bell chestpiece for wide frequency response.
- Proprietary diaphragm enhances acoustic response by 50% over traditional designs.
- Non-chill bell ring and diaphragm rims.
- Adjustable aluminum binaurals with PVC eartips.
- 21 inch PVC tubing.
- Weighs 4 oz.
- Overall length 32-1/4 inches.
- Not Made with Natural Rubber Latex.
- Bell Size: 0 – 3/5 Inch Bell
- Binaurals Material: Adjustable Aluminum Binaurals
- Chestpiece Material: Aluminum Chestpiece
- Diaphragm Diameter: 1-3/4 Inch Diaphragm
- Ear Pieces Type: 1 Pair PVC Ear Tips , 1 Pair Black Mushroom Ear Tips
- Head Type: Double-Sided Chestpiece
- Number of Tubes: 1 – Tube
- Tube Length: 22 Inch Tube
- Tube Type: Single Lumen
- Latex Free Indicator: Not Made with Natural Rubber Latex
- 12.1“ color TFT touch screen
- ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
- Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
- Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)







Reviews
There are no reviews yet.