ECROSKHIM PE-5300VI Spectrophotometer
$0.00
Shipped From Abroad
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Description
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Technical specifications:
– Spectral range, nm – 325-1000
– Separable spectral range, nm – 4
– Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
– Optical source – W-lamp
– USB-B cable for connection to a PC
– Overall dimensions, (LxWxH), not more than, mm – 440х320х175.
– Weight, not more than, kg – 8.5
– Power consumption, W – 25
– Supply voltage, V – 85-250
The standard equipment of the spectrophotometer includes:
1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm)
2. CD with software
complete set of reference light filters (4 filters)
3. Glass cuvettes, RUS standard 10x24mm (4 pcs.)
4. Dust cover
5. USB-A – USB-B cable for connection to a PC
6. Spare halogen bulb
7. Operating manual and Data sheet
PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics.
Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current
Computer software with the possibility of automatic update via the Internet
Quick Comparison
Settings | ECROSKHIM PE-5300VI Spectrophotometer remove | Avalun 48 INR Microcuvette remove | Erma B-111 Bilirubin Meter remove | Little Sister Table Top Autoclave remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | iSED Fully Automated ESR Analyzer remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | ECROSKHIM PE-5300VI Spectrophotometer remove | Avalun 48 INR Microcuvette remove | Erma B-111 Bilirubin Meter remove | Little Sister Table Top Autoclave remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | iSED Fully Automated ESR Analyzer remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF10335601227 | SF1033560084-74 | SF1033560084-6 | SF1033560084-46 | SF1033560084-89 | SF1033560084-129 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
|
| $715.00 | $1,350.00 |
|
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | Out of stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | Out of stock | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content |
Description
PE-5300VI spectrophotometer is intended for measuring the transmittance factor and absorbancy of liquids (including the biological ones) for the purpose of determining the components dissolved in them as well as for measuring the transmittance factor and absorbancy of solid and liquid samples of various origins.
Technical specifications:
- Spectral range, nm - 325-1000
- Separable spectral range, nm - 4
- Range of measurement:
a) range of measurement of absorbancy, B – 3.000 to 0.000
b) range of measurement of spectral factors of direct transmission, %T – 0.0 до 100.0
- Optical source – W-lamp
- USB-B cable for connection to a PC
- Overall dimensions, (LxWxH), not more than, mm - 440х320х175.
- Weight, not more than, kg – 8.5
- Power consumption, W - 25
- Supply voltage, V - 85-250
The standard equipment of the spectrophotometer includes:
1. PE-5300VI spectrophotometer with holder for 3 cells (RUS standard, width – 24mm, path length – to 100mm)
2. CD with software
complete set of reference light filters (4 filters)
3. Glass cuvettes, RUS standard 10x24mm (4 pcs.)
4. Dust cover
5. USB-A – USB-B cable for connection to a PC
6. Spare halogen bulb
7. Operating manual and Data sheet
PE-5300VI spectrophotometer surpasses its counterparts such as UNICO 1200 (1201), LEKI SS1104, PE-5300V, KFK-3 in a number of metrological and operational characteristics.
Features:
Warranty period – 3 years
Manual setting of wave length
Manual compensation of dark current
Computer software with the possibility of automatic update via the Internet
| LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
| Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Features:
| INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system.
Features:
• Good accuracy owning to superior CMOS sensor & our own Algorism
• 10,000 test results data storage
• Instrument Check by Reference Kit
• Remote Support available (when connected via Internet)
• Built-in Thermal Printer and Barcode Scanner
• Data export to USB(PDF, Excel), Email and LIS
• Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃
• Shelf Life of Test Cassette & Buffer : 24 months
Click Here To Download Catalogue | The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews