ECROSKHIM PE-8910 Rotary Evaporator

$0.00

Shipped From Abroad

Rotary evaporator is designed for evaporation of liquids at reduced pressure and controlled temperature in order to quickly remove solvents from mixtures of substances, as well as for separation of liquids.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF10335601242
Brands:: ECROSKHIM

Description

Description

Purpose: Rotary evaporator is designed for evaporation of liquids at reduced pressure and controlled temperature in order to quickly remove solvents from mixtures of substances, as well as for separation of liquids.

Features:
Main unit
LCD display showing the rotor speed;
Mechanical lift, maximum lift up to 135 mm;
Automatic lifting when power off;
Safe clip for attaching flasks;
Refrigerator with double helix.

Technical characteristics:
Main element
Evaporation volume, ml 50-3000
Rotation speed, rpm 20-300
Manual rotation frequency adjustment
Maximum refrigerator tilt angle 60 °
Engine power, W 40
Condenser – diagonal

Heating bath:
5 liter stainless steel coated bath;
LCD display showing current and set temperatures;
Possibility of using water or oil as a heat carrier;
Maximum heating temperature – 100 ° С (for
water), 210 ° С (for oil);
Accuracy of temperature maintenance ± 1 ° С (water) ± 2 ° С (oil)
Heating power, W 1300
Bath volume, l 5
Automatic shutdown in the absence of heat
carrier in the bath.

Overall dimensions (LxWxH) (elevator 135 mm included), mm – 380x340x692
Weight, kg – 23

Transport dimensions: 1020x540x520 mm, weight, kg – 31

Standard complete set:
Main unit – 1 pc.
Heating bath – 1 pc.
Refrigerator – 1 pc.
Receiving flask 1 l – 1 pc.
Evaporation flask 1 l – 1 pc.
Fasteners for installing the refrigerator and flasks – 1 set

The products are manufactured in accordance with TU BKRE.066264.014TU

Reviews

There are no reviews yet.

Be the first to review “ECROSKHIM PE-8910 Rotary Evaporator”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsECROSKHIM PE-8910 Rotary Evaporator removeErma B-111 Bilirubin Meter removeDiscover 14 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removeAvalun 48 INR Microcuvette removeiSED Fully Automated ESR Analyzer remove
NameECROSKHIM PE-8910 Rotary Evaporator removeErma B-111 Bilirubin Meter removeDiscover 14 Panel Cup with Adulterants Per Pack removeAlcohol Pad Per Pack removeAvalun 48 INR Microcuvette removeiSED Fully Automated ESR Analyzer remove
ImageRotary evaporator PE-8910Drug Test CupAvalun 48 INR Microcuvette
SKUSF10335601242SF1033560084-6SF1033560084-28SF1033560084-64SF1033560084-74SF1033560084-129
Rating
Price

$0.00

$0.00

$0.00

$4.25

$0.00

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad
Rotary evaporator is designed for evaporation of liquids at reduced pressure and controlled temperature in order to quickly remove solvents from mixtures of substances, as well as for separation of liquids. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Description
Purpose: Rotary evaporator is designed for evaporation of liquids at reduced pressure and controlled temperature in order to quickly remove solvents from mixtures of substances, as well as for separation of liquids. Features: Main unit LCD display showing the rotor speed; Mechanical lift, maximum lift up to 135 mm; Automatic lifting when power off; Safe clip for attaching flasks; Refrigerator with double helix. Technical characteristics: Main element Evaporation volume, ml 50-3000 Rotation speed, rpm 20-300 Manual rotation frequency adjustment Maximum refrigerator tilt angle 60 ° Engine power, W 40 Condenser - diagonal Heating bath: 5 liter stainless steel coated bath; LCD display showing current and set temperatures; Possibility of using water or oil as a heat carrier; Maximum heating temperature - 100 ° С (for water), 210 ° С (for oil); Accuracy of temperature maintenance ± 1 ° С (water) ± 2 ° С (oil) Heating power, W 1300 Bath volume, l 5 Automatic shutdown in the absence of heat carrier in the bath. Overall dimensions (LxWxH) (elevator 135 mm included), mm - 380x340x692 Weight, kg - 23 Transport dimensions: 1020x540x520 mm, weight, kg - 31 Standard complete set: Main unit - 1 pc. Heating bath - 1 pc. Refrigerator - 1 pc. Receiving flask 1 l - 1 pc. Evaporation flask 1 l - 1 pc. Fasteners for installing the refrigerator and flasks - 1 set The products are manufactured in accordance with TU BKRE.066264.014TU
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W