Edan i15 Blood-Gas Analyzer
$5,500.00
Shipped From Abroad
The Edan i15 Blood Gas Analyzer analyzes pH, pCO2, pO2, Na +, K +, Cl, Ca ++, Glu, Lact and Hct.
Delivery & Availability:
Typically 7-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
The Edan i15 Blood-Gas Analyzer analyzes pH, pCO2, pO2, Na +, K +, Cl, Ca ++, Glu, Lact and Hct. The Analyzer uses a disposable reagent pack with flushing solution, tonometers, and a waste container. You don’t need a gas cylinder. This new design avoids biological risk and environmental contamination. Routine maintenance is limited to changing the reagent pack. The unique design of the disposable sensor cards, combined with the reagent module of variable capacity according to the number of samples per day, ensure low cost and economic operation per sample. Simple menus through a touch screen guide the user on the operation of the analyzer.
It is a POCT analyzer specially designed for emergencies, it is portable, easy to use and performs flexible test panels with disposable cards. Edan i15 brings a new era in blood gas analysis by enabling faster and more efficient control and management of patient samples.
Features of Edan i15 Blood-Gas Analyzer:
- Practical reagent pack for 50 or 100 samples
- QC 3- 5 levels of control
- Built-in barcode reader
- User-friendly touch screen
- 6 types of cards with multi-combinable parameters
- Automatic sample aspiration
- Built-in printer
- Low cost per test
Technical specifications of Edan i15 Blood-Gas Analyzer:
Type of sample | Arterial, venous or capilar whole blood |
Parámetros medidos: | pH, pO2, pCO2, Na+, K+, Cl, Ca2+, Glu, Lac y Hct |
Calculated parameters: | Actual Bicarbonate (HCO3A) Standard Bicarbonate (HCO3S) Base Excess (BE) Standard Base Excess (SBE) Alveolar-arterial oxygen pressure gradient (pO2 A-a) Respiratory index. (RI) |
Sample Volume: | 140 µL |
Quick Comparison
Settings | Edan i15 Blood-Gas Analyzer remove | Avalun LabPad Device remove | 8 Bucket Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Plastic Urine Container Per Pack remove | Zenithlab (IB-9025A) Laboratory Incubator remove | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Edan i15 Blood-Gas Analyzer remove | Avalun LabPad Device remove | 8 Bucket Centrifuge remove | Skyla Hi POC Clinical Chemistry Analyzer remove | Plastic Urine Container Per Pack remove | Zenithlab (IB-9025A) Laboratory Incubator remove | ||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||
SKU | SF1033560084-291 | SF1033560084-65 | SF1033560084-114 | SF1033560060-2 | SF1033560084-106 | SF1033560084-109 | ||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||
Price | $5,500.00 |
| $72.50 |
| $8.20 | $350.00 | ||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||
Description | Shipped From Abroad The Edan i15 Blood Gas Analyzer analyzes pH, pCO2, pO2, Na +, K +, Cl, Ca ++, Glu, Lact and Hct. Delivery & Availability: Typically 7-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| ||||||||||||||||||||||
Content | The Edan i15 Blood-Gas Analyzer analyzes pH, pCO2, pO2, Na +, K +, Cl, Ca ++, Glu, Lact and Hct. The Analyzer uses a disposable reagent pack with flushing solution, tonometers, and a waste container. You don’t need a gas cylinder. This new design avoids biological risk and environmental contamination. Routine maintenance is limited to changing the reagent pack. The unique design of the disposable sensor cards, combined with the reagent module of variable capacity according to the number of samples per day, ensure low cost and economic operation per sample. Simple menus through a touch screen guide the user on the operation of the analyzer.
It is a POCT analyzer specially designed for emergencies, it is portable, easy to use and performs flexible test panels with disposable cards. Edan i15 brings a new era in blood gas analysis by enabling faster and more efficient control and management of patient samples.
Features of Edan i15 Blood-Gas Analyzer:
Technical specifications of Edan i15 Blood-Gas Analyzer:
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | 800-1 electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages.
Technical Specifications:
Click Here To Download Catalogue | skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results.
Reagent Kit
Main SpecificationPrinciple
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and SamplesSamples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
HumidityRelative humidity < 95% (Non-condensing)
|
| Features:
| ||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Additional information |