Electrosurgical Bipolar Forceps

$0.00

Shipped From Abroad

Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130165-18
Brands:: OBS

Description

 

Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.

Reviews

There are no reviews yet.

Be the first to review “Electrosurgical Bipolar Forceps”

Your email address will not be published. Required fields are marked *

Quick Comparison

Electrosurgical Bipolar Forceps removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit removeDisposable Subdermal Needle Electrodes removeReusable Silicon Electrosurgical Pad remove
NameElectrosurgical Bipolar Forceps removeOBS-100C LCD Version Dual cold RF Electrosurgical Unit removeBipolar Irrigated Coagulator removeOBS-100C(I) Intelligent Electrosurgical Unit removeDisposable Subdermal Needle Electrodes removeReusable Silicon Electrosurgical Pad remove
Image
SKUSF1033560130165-18SF1033560130165-1SF1033560130165-12SF1033560130165-2SF1033560130165-25SF1033560130165-17
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Electrosurgical Bipolar Forceps are specialized surgical instruments used in electrosurgery. They have two electrodes at the tips, which allow for precise control of electrical current to coagulate, cut, or seal tissue with minimal damage to surrounding areas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for  Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Reusable Silicon Electrosurgical Pad is a grounding pad made from medical-grade silicone. It's designed for use in electrosurgery to disperse electrical current safely. It features a large surface area, adhesive backing, and connectors for attachment to electrosurgical units. This pad can be sterilized and reused, making it cost-effective and suitable for various surgical procedures.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content  
Features:
  1. Two Electrodes: The tips of the forceps act as both the active and return electrodes.
  2. Precision Control: Allows for targeted application of electrical energy.
  3. Reduced Risk of Burns: The current is confined between the forceps, minimizing the risk of accidental burns.
  4. Reusable: Often made from stainless steel or titanium and can be sterilized for multiple uses.
  5. Variety of Designs: Available in straight, angled, and bayonet styles to suit different surgical needs.
Uses:
  1. Coagulation: Used to stop bleeding by coagulating blood vessels.
  2. Tissue Cutting: Can be used to cut tissue with precision.
  3. Sealing: Effective in sealing blood vessels and tissue bundles.
  4. Versatility: Used in various surgical fields such as general surgery, gynecology, neurosurgery, and ENT (Ear, Nose, and Throat) surgery.
Features
  • Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
  • The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
  • No pressure cutting and the pencil is operated easily and it's full of flexibility.
  • No carbonation, less bleeding, and no adhesions.
  • Less pain, scarring, and fast healing after operation.
Technical Parameters
Image
Product Details
OUTPUT MODE 
  • CUT - For micro-smooth cutting
  • BLEND - For cutting with coagulation
  • HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
  • FULGURATION - For desiccation or fulgurate spark-gap
  • BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
  • Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
  • Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
  • Hemostasis: control of bleeding, epilation, telangiectasia.
  • Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae, hemostasis.
  • Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Transportation Data :
  • WxHxD:34(L)'23.5(W)*10.6(H) 49(L)*35.5(W)'31(H)cn Weight:8.2kg(NetWeight);12. cm(Generator) i(outer carton) 1kg(Gross Weight)
  • Standard Matching Accessories
  • Instruction for Use: 1pc
  • Power Cord: 1pc
  • Dual Pedal Switch: 1pc
  • Disposable ESU Pencil: 2 pes
  • Reusable Antenna Pad with cable: 1 set
  • Reusable Bipolar Forceps with Cable: 1 set
  • Reusable ESU pencil: 1 pc
  • Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
  • Disposable leep Electrode tips: 5pcs
Features

1. LED light positioned between the electrodes enhances the vision during surgery.

2. Massive area hemostasis can be performed in a short time in order to reduce intraoperative blood loss 3. Saline line and dripping device are equipped in an attempt to contain the heat on the treated tissue and avoid thermal tissue damage
Indications for Use
  • Ensure that both electrodes are in contact with the tissue to be treated. Activation and saline flow occur simultaneously.
  • Ensure that saline is flowing at the time of activation
  • These devices should never be used when:
  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range: 5°C~ 40°C
Relative moisture range: ≤80%
Atmosphere pressure range: 86.0 ~ 106.0 Kpa
 Working modes:
Pure cut: 1w ~ 60w (Load 500Ω)
Blend: 1w ~ 60w (Load 800Ω)
Coagulation: 1w ~ 60w (Load 1000Ω)
Fulguration: 0.1w ~ 35w (Load 1000Ω)
Bipolar: 1w ~ 30w (Load 200Ω)
Technology data:
Voltage: 220V±10V, 50Hz ±1Hz
Working frequency: 357 KHz ~ 575 KHz
Leakage currents to ground: Less than 0.5mA
Leakage currents to patient: Less than 0.01mA
Display Setting: Fulguration a.      0-10 range: 0.1watt increments b.      10-35range: 1.0 watt increments Cut, Blend, Coagulation, and Bipolar 1.0-watt increments Power supply:220V±10%,50±1%Hz. Transportation and storage a)        Ambient temperature range: -40°C~55°C; b)        Relative moisture range: ≤95%; c)        Atmosphere pressure range: 500hPa~1060hPa. Accessories Included: Electrosurgical Pencil, disposable                           2pcs Bipolar Forceps with cable, reusable                      1pc Disposable Electrosurgical Pad                               2pcs Cable for Electrosurgical Pad, reusable                  1pc Footswitch                                                              1pc Power cord                                                             1pc Manual                                                                    1pc
Features:
  1. Material: Made from medical-grade silicone, which is durable and flexible.
  2. Reusable: Can be used multiple times after proper sterilization, making it cost-effective.
  3. Adhesive Backing: Comes with an adhesive side to securely attach to the patient's skin.
  4. Large Surface Area: Designed to disperse electrical current over a wide area to minimize the risk of burns.
  5. Connectors: Typically equipped with connectors like REM or banana connectors for easy attachment to electrosurgical units.
Uses:
  1. Electrosurgical Procedures: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
  2. Patient Safety: Ensures safe operation of electrosurgical units by dispersing the electrical current away from the patient's body.
  3. Versatility: Suitable for different types of surgeries, from open surgeries to laparoscopic procedures.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare