Electrotherapy electrodes are an essential component of electrotherapy treatments, which use electrical currents to manage pain, improve circulation, repair tissues, and strengthen muscles. These electrodes are typically adhesive pads that stick to the skin and deliver mild electrical pulses to the targeted area
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrotherapy electrodes are an essential component of electrotherapy treatments, which use electrical currents to manage pain, improve circulation, repair tissues, and strengthen muscles. These electrodes are typically adhesive pads that stick to the skin and deliver mild electrical pulses to the targeted area
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From AbroadElectrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Unique dual radio frequency design. Combines 4Mhz and 1.7Mhz into one generator. Realizes the best operation result effectively. Suitable for Plastic, Dermatology, ENT, Ophthalmology, Dentistry, Podiatry and Spinal surgery
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From AbroadReusable Silicon Electrosurgical Pad is a grounding pad made from medical-grade silicone. It's designed for use in electrosurgery to disperse electrical current safely. It features a large surface area, adhesive backing, and connectors for attachment to electrosurgical units. This pad can be sterilized and reused, making it cost-effective and suitable for various surgical procedures.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Key Features
OBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience.
1. Two levels of coagulation: pinpoint coagulation and fulguration
Pinpoint coagulation provides precise control of bleeding in localized areas.
Fulguration provides greater control of bleeding in highly vascular over-surface areas.
2. Presets
The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings.
3. Isolated RF output for Cut, Blend, and Coag modes
This minimizes the potential of alternate site burns.
4. Ground Referenced RF output for Fulguration modes
5. Self-diagnostics
These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.
Technical parameters:
Environmental temperature range:
5°C~ 40°C
Relative moisture range:
≤80%
Atmosphere pressure range:
86.0 ~ 106.0 Kpa
Working modes:
Pure cut:
1w ~ 60w (Load 500Ω)
Blend:
1w ~ 60w (Load 800Ω)
Coagulation:
1w ~ 60w (Load 1000Ω)
Fulguration:
0.1w ~ 35w (Load 1000Ω)
Bipolar:
1w ~ 30w (Load 200Ω)
Technology data:
Voltage:
220V±10V, 50Hz ±1Hz
Working frequency:
357 KHz ~ 575 KHz
Leakage currents to ground:
Less than 0.5mA
Leakage currents to patient:
Less than 0.01mA
Display Setting:
Fulguration
a. 0-10 range: 0.1watt increments
b. 10-35range: 1.0 watt increments
Cut, Blend, Coagulation, and Bipolar
1.0-watt increments
Power supply:220V±10%,50±1%Hz.
Transportation and storage
a) Ambient temperature range: -40°C~55°C;
b) Relative moisture range: ≤95%;
c) Atmosphere pressure range: 500hPa~1060hPa.
Accessories Included:
Electrosurgical Pencil, disposable 2pcs
Bipolar Forceps with cable, reusable 1pc
Disposable Electrosurgical Pad 2pcs
Cable for Electrosurgical Pad, reusable 1pc
Footswitch 1pc
Power cord 1pc
Manual 1pc
Features:
High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
Adhesive Backing: They usually have an adhesive side to securely attach to the patient's skin.
Flexible Design: They are designed to conform to the contours of the patient's body.
Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
Features
Clinic result proves that higher frequency can get less tissue resists nee. 4Mhz frequency can reduces heat injury a ind carbonizing to tissue at maximum. It realizes low temperature cutting.
The antenna pad is unnecessary for skin touch, no current goes through the body, and no possibility of burning
No pressure cutting and the pencil is operated easily and it's full of flexibility.
No carbonation, less bleeding, and no adhesions.
Less pain, scarring, and fast healing after operation.
Technical Parameters
Product Details
OUTPUT MODE
CUT - For micro-smooth cutting
BLEND - For cutting with coagulation
HEMO - For pure Hemostasis-Coagulation to control most forms of bleeding
FULGURATION - For desiccation or fulgurate spark-gap
BIPOLAR - For precise coagulation utilizing bipolar energy
INTENDED USE
Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses, tumors, cosmetic repairs, development of skin flaps, skin tags and blepharoplasty.
Blended (cutting and coagulation): snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae. basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses, and development of skin flaps.
Hemostasis: control of bleeding, epilation, telangiectasia.
Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry), snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP), myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Reusable Fine Electrode tips (Needle, curved, Needle .Ball): 7pcs
Disposable leep Electrode tips: 5pcs
The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
Power output can be controlled by the easy to use power adjustment button on the electrosurgical hand pencil which can shorten the operation time.
With the inbuilt memory function on the device, you can set the required function parameters then power off the unit, next time the unit is powered on, the unit the last set parameter will be displayed.
Output power of between 10 and 30 watts or less can be adjusted up and down by 0.1-watt increments, which is suitable for various delicate procedures.
It can be used with disposable dispersive electrode
What's in the box?
x1 OBS-50 High-Frequency Electric Coagulator Unit
x1 Reusable power control electrosurgical pencil
x10 Non-Sterile Single-Use Short Sharp Tips
x10 Non-Sterile Single-Use Short Blunt Tips
x1 Power cord
x1 Instruction manual
Multiple Applications to meet your different clinic demands
Desiccation
Monopolar output mode without using the dispersive electrode
Contact or insert into the tissue with the electrode
The unit produces a high-frequency current, which runs through the patient via the electrode and then returns to the unit through grounding.
High-frequency current vaporises the liquid inside the tissue cell therefore causing denaturation on the protein
Fulguration
Another monopoly output mode without using a dispersive electrode
Holding the electrode above the lesions rather than contact directly, will release an electric arc to the tissue.
Range of action in this mode is limited to the surface where the arc contacts the tissue
Coagulation
Suitable for hemostasis and shrinkage of tissue
Used in control of hemostasis
Suitable for more difficult cutting procedures for good hemostasis
Monopolar coagulation
Monopolar output mode using the dispersive electrode
Under this mode, the high-frequency current that is produced from the unit flows through the patient and then returns to the unit via a dispersive electrode
The dispense electrode can draw more high-frequency current to the electrode, making the tip of electrode produce a more powerful desiccation to the tissue.
Bipolar Coagulation
An Output mode in which the high-frequency current circulates between two nearby electrodes (bipolar forceps), without using the dispersive electrode.
In contrast to the effect of monopolar coagulation, since the high-frequency current is only circulated separately in the forceps, the bipolar coagulation effect acts only on the tissue surface, causing minimal damage to the tissue.
Standard Accessories (Can be purchased Separately)
Reviews
There are no reviews yet.