Description | Shipped From Abroad
Elisa microplate washer is a laboratory instrument designed to automate the washing steps required in ELISA assays. These washers are used to clean the wells of microplates, removing any unbound substances to ensure accurate detection and reduce background noise.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Aboard
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Elisa Microplate Washer Features:
- Large LCD with menu design for easy use
- Whole plate cleaning or single strip cleaning
- Waste liquid overflow alarm function
- One-point, two-point and whole-bottom washing
- Flat bottom, V-bottom or U-bottom strip cleaning
- Large memory for storing up to 48 user-programmed cleaning programs
Elisa Microplate Washer Specifications:
Model |
ELMW-310 |
ELMW-320 |
Input |
8 key membrane keyboard |
Display |
High brightness LCD display screen |
Manifold |
8 pins and 12 pins |
Wash Mode |
Strip mode and plate mode |
Wash Strips |
1~12 adjustable |
Applicable Well |
Flat, V-bottom or U-bottom |
Washing Times |
0~99 times adjustable |
Dipping Time |
0~3600s adjustable |
Shaking Time |
0~600s adjustable |
Residual Volume |
≤1μL/well |
Liquid Volume |
50~3000ul/well |
Sipping Time |
0.1~9.9s |
Storage Capacity |
More than 100 user defined wash board procedures |
Power Supply |
220V, 50Hz |
Washing Fluid Channel |
1 |
1 (Optional: 2-4 Channels) |
Sizes(W×D×H)(mm) |
448x382x163 |
Shipping Size (W×D×H)(mm) |
620x550x490 |
N.W./G.W. (kg) |
10/16 |
|
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
- User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
- Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
- Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
|
- Made of high quality PP material with good transparency.
- Applied for Gilson/Finland/Eppendorf Pipettors.
- Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
- Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
- Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Classification: PIPETTE
Brand Name: Vchanslab,Yingmed,OEM
Model Number: YM-K7028
Place of Origin: China
Product name: Pipette Tips
Material: Polypropylene
Certificate: CE/ISO13485/FDA
Color: Natural, Blue, Yellow
Application: Laboratory, Teaching, Hospital | The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
-
-
100µL sample drawn directly from primary EDTA tube
-
Fully automated, walk-away operation
-
-
Positive patient identification via internal barcode reader
-
Compatible with pediatric tube
Technical Specifications:
Principle of Measure: |
Photometrical |
Results: |
“Printed mm/hr, Range from 1-130 mm/hr” |
Sample Requirements: |
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated. |
Tube Requirements: |
13 x 75 mm, pierceable capped tube |
Quality Control: |
Barcoded Seditrol® QC |
Barcode Reader: |
Internal |
Printer: |
Internal |
Interface Specifications: |
serial RS232 port for LIS connection |
Weight: |
14 kg |
Dimensions (H x W x D): |
36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in) |
Voltage: |
100-240VAC |
Frequency Range: |
50-60 Hz |
Power: |
160W |
Click Here To Download Catalogue | This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
- Lowest operation and tip ejection forces
- Fully autoclavable
- Ultra light weight with space-age materials
- Secondary adjustment option for various liquid classes
- Spring loaded tip con
- For transferring molecular samples and PCR mix solutions.
- One set is for DNA work and the other for RNA work. Each with the following specs
- Light weight, traditional tip shaft, and will fit all generic brands of tips
- Equal to or better than accuracy and precision compared to ISO 8655, so results can be trusted.
- Easy and quick volume adjustment with or without gloves. Foolproof volume lock prevents accidental volume changes.
- Low maintenance and autoclavable 121° for at least 20 minutes
- Quick release
| The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric
analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.
Feature
- Auto zero function: Manual blanking not required
- Dual wavelength measurement system:
- 2 wave lengths 455nm and 575nm
- Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
- LED Light source:
- LED does not require replacement as it lasts longer
- As compared to Lamp, LED are more suitable as there is no intensity fluctuations
- No warm up time required.
- Flexible unit selection:
- Two units either mg/dl or umol/L are selectable, ease of reporting
- Compact slot for Capillary:
- Accuracy of results are directly related to proper alignment of Capillary
- B-111 has the easiest mode to ensure precise values
- Data transfer:
- External device can be connected to instrument through RS232 por
- USB port
Technical Specification
- Light source - LED
- Wavelength - 455nm and 575nm
- Net weight - 1kg
- Measuring range - 0-30 mg/dl , 510 umol/L
- Display - 16×2 LCD module with backlight
- Auto calibration - Yes
- Sample type - Serum or plasma
- Sample volume - 40-80μL
- Test time - <5sec
- Units - mg/dl or umol/L
- Dimensions - 150 (W) × 115 (H) × 190 (D) mm
- Interface - RS232
- Reading cuvette - Heparinized micro capillary holder
- Storage temperature - 15-40°c
- Power supply - DC 9V(DC adapter)
- Power consumption - <2W
|
Reviews
There are no reviews yet.