Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check archive
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | Features:
- Using the ARM processor and the latest domestic image processing, the system is fast and the image is clear.
- Japan’s mature optical path system, humanized automatic mist measurement process, to reduce the error caused by adjustment, more precise measurements.
- Light rack with integral casting, CNC machining, the measuring system is more stable, good consistency.
- Color LCD display, 5.7 inches man-machine interface is more comfortable.
- PD automatic measurement function, automatically PD value.
- One key lock function, quickly locking mobile platforms.
- Innovative designs, according to the structure of human body engineering, to bring customers good aesthetic feeling and comfortable.
- Data transmission with CV7200, improved efficiency of online 5x magnification options, respond to different viewing needs.
Technical Specifications:
Measurement Range
Vertex distance.......................................0.0,12.0,13.75,15mm
Sphere.......................................-20D~+20D(0.12/0.25D step)
Cylinder...........................................0~±10D(0.12/0.25D step)
Axis...............................................................1~180°(1° step)
PD distance............................................................30~85mm
PD..........................................................................10~86mm
Minimum pupil diameter..............................................Ø2.0mm
Target................................................automatic fogging target
Hardware specifications
Monitor.............................................................5.7" color LCD
Printer......................................................Fast thermal printer
Power saving function....................OFF, 5/15 mins (selectable)
Power supply................................AC110~220V, 60/50Hz, 50W
Dimension/weight..............................288x500x480mm(14kgs) | Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing.
Features of Handheld Digital Auto-refractometer:
- Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
- Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
- Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item |
Range |
Interval |
Tolerance |
Spherical (S) |
Myopia Mode |
-9.00D~ +2.50D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Normal Mode |
-6.00D ~ +8.00D |
Cylindrical(C) |
-3.00D~0.00D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Axis(A) |
0°~180° |
1° |
±5° |
| Feature:
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by a pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check the archive
Technical Specifications:
Model |
SW-1000 Ophthalmic A Scan Biometer |
A Scan |
A scan probe |
10MHz import small size probe, built-in luminotron |
Measuring range |
15mm-40mm |
Measurement precision |
±0. 05mm; with macula lutea trace function |
Measurement |
Anterior chamber depth, lens thickness, vitreous body length, total length and average |
Method of measurement |
immersion and contact |
Eye mode |
Phakic/ Aphakic/Dense/ various IOL |
IOL formula |
SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS |
Storage |
10 cases, 5 readings each case |
Output |
A scan waveform and IOL calculation sheet
|
| Features:
- Ultra-portable: This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities. Its easy-to-operate optical system produces a high-brightness, continuously adjustable slit image ideal for pediatric and geriatric setting, emergency department screenings, ward rounds, beside examination, post-op evaluations, and mission work;
- LED illumination: the first and the only portable slit lamp in the world applying LED illumination system. The most prominent advantage of our LED illumination system gives the examiner the clearest image without glare;
- Comfortable using experience: The low heat radiation from our LED lamp makes the most comfortable examine experience for the patient;
- Sharpest Slit: With the blade imaging system S150 gives equally sharpest slit as the best classic slit lamp in the world;
- No need to replace illumination lamp: The LED lamp used in S150 portable slit lamp is rated 20,000 hours at full power. Its lifetime is almost 10 times longer than a normal halogen lamp;
- Power-saving: S150 can work for long hours without changing batteries.
Technical Specifications:
- Magnification: 5x
- Range of slit length: 5mm~11mm
- Minimum slit width: 0.2mm
- Working distance: 12~32mm
- Power supply: AA batteries x 2
- Illumination: LED blub(3.3V/1W)
- Battery life: More than 3h(AA alkaline batteries x 2)
- Net weight: 150g(without batteries)
How to Operate:
- Press the Power Switch to turn the slit lamp on/off
- Loosen the Locking Screw
- Twist the Lamp Body while holding the Magnifier Bracket still till the slit is in the required angle
- Push or pull the Lamp Body while holding the Magnifier Bracket still to set the Magnifier into a position comfortable for observation
- Fasten the Locking Screw
- Pull the Lamp Head back and forth for adjusting the width and the length of the slit, as well as the intensity of the light
| Functions of Ophthalmic AB Scan Machine:
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan |
1.Probe: 10MHz frequencies, with LED
2.Depth: 40mm
3.Precision: ±0.05mm
4.Eye mode: Phakic / Aphakic / Dense / Various IOL
5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat.
7.Calculation: Average and standard deviation
8.Store: 10 Scanning results for each eye |
B scan |
1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless
2.Scanning Mode: Sector Scanning
3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm
4.Geometric Location Precision: Lateral≤10%; Vertical≤5%
5.Depth: 60mm
6.Enhance the part of vitreous body and retina
7.Gain of probe:30dB-105dB
8.Scanning Angle : 53°
9.Gray Scale: 256
10.False Color: Multi colors OTC
11.Measure Mode: distances, perimeter and area
12.Movies: 100 images movie review,AVI ZIP JPG format image output
13.Output: PDF format case report, connect to normal printer |
Others |
1.Display Mode :B, B+B, B+A, A
2.Hint: preset keyword
3.Case Search: Multi-keywords
4.Working Platform: Windows XP, VISTA, WINDOWS7
5.User-defined report template |
|
Reviews