Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
YZ20P5 Operation Microscope is a simple binocular coaxial microscope for a single man. The Operation Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| 83Shipped from abroad
This is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | | The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
| Functions of Ophthalmic AB Scan Machine:
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
A scan |
1.Probe: 10MHz frequencies, with LED
2.Depth: 40mm
3.Precision: ±0.05mm
4.Eye mode: Phakic / Aphakic / Dense / Various IOL
5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat.
7.Calculation: Average and standard deviation
8.Store: 10 Scanning results for each eye |
B scan |
1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless
2.Scanning Mode: Sector Scanning
3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm
4.Geometric Location Precision: Lateral≤10%; Vertical≤5%
5.Depth: 60mm
6.Enhance the part of vitreous body and retina
7.Gain of probe:30dB-105dB
8.Scanning Angle : 53°
9.Gray Scale: 256
10.False Color: Multi colors OTC
11.Measure Mode: distances, perimeter and area
12.Movies: 100 images movie review,AVI ZIP JPG format image output
13.Output: PDF format case report, connect to normal printer |
Others |
1.Display Mode :B, B+B, B+A, A
2.Hint: preset keyword
3.Case Search: Multi-keywords
4.Working Platform: Windows XP, VISTA, WINDOWS7
5.User-defined report template |
| Operation Microscope(YZ20P5) is a simple binocular coaxial microscope for a single man. The Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Features of Operation Microscope:
- Multi-layer coating technology is used on optical lenses to enhance the transmission rate and prevent mildew.
- Foot-controlled focus, three-step magnification change, good depth of field of view, and good binocular fusion to meet the need of cataract surgery.
- Using apochromatic technology to make different wavelengths of the light focus near the focal point behind the lens, so as to make the operator's vision more clearly.
- The machine weighs only 41Kg to be light and compact and is especially applicable for mobile medical.
- Optional desktop components to make the machine more portable and can also be customized according to special requirements to meet the needs in ophthalmology, ENT and other surgery.
- Optional F250/F300/F400 lens.
Technical Specifications of Operation Microscope:
Eyepiece Magnification
|
12.5×
|
Focal Length of Objective Lens
|
F=200
|
Working Distance
|
190 mm
|
Magnification for Main Microscope
|
5.3×, 8×, 16×
|
Diameter of Field
|
37 mm, 25 mm, 16.7 mm
|
Diopter Adjustment
|
±5D
|
Pupillary Distance
|
50 mm ~ 70 mm
|
Maximum Resolution
|
100 LP/mm
|
Light Source
|
12V/100W halogen lamp for medical use
|
Illumination Type
|
6° coaxial illumination of the cold light source
|
Coaxial Illuminance
|
≥30,000 Lx
|
Reaching Radius of Arm
|
870 mm
|
Adjustable Vertical Range
|
700 mm~1100 mm
|
Fine Focusing Range |
30 mm |
Input Voltage
|
AC 220V/110V±10%, 50Hz/60Hz
|
Power Consumption
|
120 VA
|
Fuse
|
AC 250V T4.0A, AC 125V T8.0A
|
Electrical Safety Standard
|
IEC 60601-1, Class I
|
Packing Volume
|
0.2 m3,1 carton
|
Total Weight
|
41 kg
|
| Portable Fundus Camera is a portable medical camera for fundus imaging, diagnosis, and especially for fundus disease screening. It's compact, easy to obtain high definition fundus image. It can be conveniently applied to rapid screening, out diagnosis, bedside diagnosis and remote medical treatment, etc.
Features of Portable Fundus Camera:
- Images real-time display, one-button magnifying
- Non-mydriatic and high definition imaging.
- Micro SD memory card up to 32GB for 80,000 images
- USB and WiFi connection
- Low weight 450g, movable and portable
- A rechargeable battery provides up to more than 4 hours of continuous operation.
- Optional imaging modules for examination: posterior ophthalmoscope, anterior segment ophthalmoscope, otoscope, rhinoscope, laryngoscope and dermatoscope
- High definition and stable image
- Easy one-handed operation and excellent portability
- Large data service and a variety of image acquisition mode
Technical Specifications of Portable Fundus Camera:
Model |
MC-600 |
FOV |
45° |
Minimum pupil |
2.5mm |
Refractive compensation |
-20D~+20D |
Light source |
White LED/IR |
Image resolution |
1920×1080 |
Focus Mode |
Manual |
Screen |
3.5" color |
Power |
≤6VA |
Storage |
8GB Micro SD card |
Power supply |
3.7VLithium Battery |
Interface |
Mini USB/Wifi |
N. Weight |
450g(Typical) |
G. Weight |
2.5kg |
Size |
160mm*90mm*190mm |
Packing size |
360mm*310mm*160mm |
| Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing.
Features of Handheld Digital Auto-refractometer:
- Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
- Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
- Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item |
Range |
Interval |
Tolerance |
Spherical (S) |
Myopia Mode |
-9.00D~ +2.50D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Normal Mode |
-6.00D ~ +8.00D |
Cylindrical(C) |
-3.00D~0.00D |
0.25D |
±0.50D or ±20%
(whichever is greater) |
Axis(A) |
0°~180° |
1° |
±5° |
|
Reviews