Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from Abroad
- Contains Output interface for Anesthesia information management system.
- Complete with backup battery for working more than 120 minutes.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
- 5.5" monochrome TFT LCD screen
- Built in Anesthesia ventilator
- Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
- Updated high brightness LED lamp
- Compact CO2 absorber (autoclavable)
- Optional: Continuous FIO2 monitoring
- Optional: Anaesthesia gas scavenging system
- Optional: Yoke system for 5L O2/N2O cylinders
- Optional: Integrated suction unit on air
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
- High quality & Durability Design
- Easy operation & easy maintenance
- Compact construction
- Beautiful & delicate
- Space saving for operation room.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation.
Application Field: Neonates, Pediatrics & Adults
Ventilation Modes: Volume controlled (VC), Pressure controlled (PC), Adaptive Pressure with Volume Guaranteed (APVG) & Pressure Support Ventilation (PSV)
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Advantage:
1 .All components manufactured by us
2. Catheter with/without metal wire is available
3. Available as individually packaged and bulk packaged
4. With the choice of different parts, these kits provide versatility in catering to individual needs and preferences.
5.It can be customized according to different market demands.
Components Included
No. |
Component name |
Specification |
1 |
Epidural needle(Tuohy needle) |
16/18G*80mm |
2 |
Epidural catheter |
multiport with mark 0.8/1.0mm, length≥850mm |
3 |
Epidural filter |
Epidural filter:0.22/0.2μm, hydrophobic membrane, Luer lock |
4 |
LOR syringe |
Both 5ml,7ml and 10ml specifications are available |
5 |
Catheter adaptor |
TBA, secure the catheter completely |
|
Features:
- Contains Output interface for Anesthesia information management system.
- Complete with backup battery for working more than 120 minutes.
|
- 5.5" monochrome TFT LCD screen
- Built in Anesthesia ventilator
- Updated 2 high precise vaporizers ZF-3000 (Volume > 250ml)
- Updated high brightness LED lamp
- Compact CO2 absorber (autoclavable)
- Optional: Continuous FIO2 monitoring
- Optional: Anaesthesia gas scavenging system
- Optional: Yoke system for 5L O2/N2O cylinders
- Optional: Integrated suction unit on air
|
- High quality & Durability Design
- Easy operation & easy maintenance
- Compact construction
- Beautiful & delicate
- Space saving for operation room.
| The Genesis anaesthesia workstations meet your most ambitious requirements. They stand out for their lung protective ventilation, accuracy and performance, cost saving, design and ergonomics, safety and versatility.
TECHNICAL SPECIFICATION
OPERATING DATA
- Weight - 105 kg
- Dimensions - 92 cm Wide x 68 cm Deep x 139 cm High (93 cm to the table surface)
- Packaging Dimensions - 105 cm Wide x 75 cm Deep x 160 cm High
- Operating voltage supply - 110 to 240 V~, 47 to 63 Hz (12 to 6 A)
- Power input - 120 W typically (max. 1.2 kW with auxiliary outlets used)
- Battery autonomy - 90 min typically
- Auxiliary power outlets - 4, with automatic protection
- O2, N2O and Air supply - 2.7 to 6.9 bar (39.1 to 100 psi)
- Screen - TFT 18.5" (47 cm) projected capacitive touchscreen
- Protection class - Class I, gas analyser type BF defibrillation proof
- Classification - Class II b
- Storage - One front drawer with self-brake system and two back cabinets with door
- Lighting - LED bar below the screen controlled from the touchscreen
- Auxiliary integrated systems - Auxiliary 02 flow meter (0-15 L/min), Auxiliary 02 suppy valve (NF standard) and Suction device
- Communication ports - 1 x RS-232, 2 x USB, 1 x LAN Ethernet
Fresh Gases (02, N20 and Air, electronically controlled)
- Fresh gas flow - 0 and 0.1 to 18 L/min 02/N20/Air
- Accuracy - 0.1 to 0.5 L/min = ±0.05 L/min; 0.5 to 18 L/min = ±10 %
- 02 concentration - 21 to 100% vol. with Air, 25 to 100% with N20 (minimum 200 ml/min 02)
- 02 Safety fresh gas (backup) - 0-0.2-0.4-0.7-1-1.5- 2- 3- 4- 6- 8-10-12-15 L/min 02
- 02 flush (+02) - 40 L/min standard (adjustable 25 - 75 L/min upon requirement)
Breathing System (CABS)
- Autoclavable - 134 °C
- Weight of breathing system - 9.8 kg
- C02 absorber volume - 1.5 L
- Leakage - < 150 mL/min (at 30 hPa)
- Pressure limiting valve APL - 0 to 70 hPa
- Pressure relief valve - 125 hPa
- Vacuum safety valve - 0.3 hPa
- resistance at 60L/min - 5.80 hPa
- resistance at 60L/min - 2.90 hPa
- resistance at 30L/min - 3.55 hPa
- resistance at 30L/min - 0.89 hPa
- Internal Compliance at 30 hPa - 15 mL
VENTILATOR
Operation / Ventilation Modes
Volume controlled (VC) modes:
- Volume Controlled Ventilation (VCV)
- VC Synchronized Intermittent Mandatory Ventilation (VC-SIMV)
- VC-SIMV with Pressure Support (VC-SIMV-PS) *
Pressure controlled (PC) modes:
- Pressure Controlled Ventilation (PCV)
- PC Synchronized Intermittent Mandatory (PC-SIMV)
- PC-SIMV with Pressure Support (PC-SIMV-PS) *
Adaptive Pressure with Volume Guaranteed (APVG) modes (other trade names: Autoflow,PCVR, PRVC, AVAPS, VC+)
- Adaptive Pressure with Volume Guaranteed (APVG) *
- APVG Synchronized Intermittent Mandatory (APVG-SIMV) *
- APVG -SIMV with Pressure Support (APVG-SIMV-PS) *
Pressure Support Ventilation (PSV) *
- (other trade names: PS, ASB, SPS, IPS)
Non-mechanical Operation / Ventilation Modes
- Manual ventilation through the CABS system (Auto/Manual software controlled)
- Spontaneous ventilation either through the bellows (auto mode) or through the bag
- (manual mode) Manual ventilation through the external fresh gas outlet for non-rebreathing systems (Bain, Mapleson, ...)
Application field: Neonates, Pediatrics & Adults
- Tidal volume - 5 to 1500 mL
- Inspiratory pressure - 0 to 68 hPa
- Ventilation frequency - 3 to 120/min
- Inspiratory time - 0.05 to 16.6s
- l:E ratio - 5:1 to 1:8
- Inspiratory pause - 0 to 60%
- Inspiratory flow - max. 150 L/min
- PEEP - 0 to 30 hPa
- Flow trigger - 0.2 to 15 L/min
- Pressure support - 5 to 50 hPa
- Ramp time - 0.1 to 2 s
- Maximum pressure - 0 to 68 hPa
MONITORING
- 5" (47 cm) projected capacitive touchscreen, supported on a 360° rotating and 2 axis tilting arm.
- Measurements displayed: Peak pressure; Plateau pressure; Mean pressure; Expiratory minute ventilation; Expiratory tidal volume; Inspiratory tidal volume; Expiratory volumeter; Breathing rate; Compliance and Resistance (in VC modes); Patient info (age, weight, MAC, Class ASA); Connected sensors; Battery status; Power supply status; Gases supply pressures for 02, N20 and Air; Inspiratory and expiratory concentration of 02, N20, C02 and Anaesthetic gas*
- Parametres charted as curves (up to 3 simultaneously): Airway pressure; Expiratory flow; Inspiratory flow; Volume; Fresh gases (Rotstyle); Concentration of 02, N20, C02 and Anaesthetic gas*; Trends: Minute volume, MAC and gases (02, N20, C02 and Anaesthetic gas).
- Display for the performance of the hospital Anaesthetic Gas Scavenging System (AGSS).
- Configurable interface: bright/dark, multi-language.
- Loops (up to 2 simultaneously): Volume-Pressure, Flow-Volume, Pressure-Flow, C02-Volume.
- Fresh gas virtual rotameters for 02, N20, Air. * C02, N20 and Anaesthetic gas monitoring with the accessory multigas analyzer main-stream or side-stream; 02 real-time monitoring via paramagnetic
| I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size. |
Reviews
There are no reviews yet.