New

Fluorescence Spectrophotometer

Ask for Price$0.00

Shipped From Abroad

Model : SP-FL96P

This compact fluorescence spectrophotometer is designed to provide high sensitivity fluorescence detection during quantification of nucleic acids and is easy to operate.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Scitek

Description

Fluorescence Spectrophotometer Features:

SP-FL96P fluorescence spectrophotometer is so sensitive that it has become an important analytical method in measurement analysis.

  • Provides wavelength, time scanning (kinetic analysis) and quantitative analysis functions.\
  • 365nm excitation wavelength Raman peak S/N≥150 for water in 1cm quartz fluorescence cuvette High-performance sensitivity simplifies the measurement of low detection samples.
  • 17 levels of gain adjustment are selectable for emission spectrum scanning, including high-speed low signal-to-noise ratio scanning and precision scanning. Full spectrum scanning can be completed within 1 second.
  • Intelligent pre-scan function for fast detection of spectral information of unknown samples. And it can automatically ignore the effect of scattering peaks and harmonic peaks.
  • Support offline mode and online mode.
  • 150W xenon lamp and power supply to ensure high stability and a wide spectral range of testing.
  • The normalization feature of fluorescence value can make the results of different fluorescence comparable.
  • Optional PC qualitative and quantitative software package with expandable time scanning, wavelength scanning, graphical calculation and storage access.

 

Fluorescence Spectrophotometer Specifications:
Model SP-FL96P
Light Source Hamamatsu 150W Xenon lamp
Exciting Optical Filters Interference optical filter
Emission Monochromator C-T diffraction grating
Emission Wavelength 200-900nm
Emission Bandwidth 10nm
Sensitivity S/N≥150(P-P)
Linear ≥0.995
Stability Better than 1.5%/10min
Power 220V±22V; 50Hz±1Hz
Response Time (0.1-4)s 6 stages adjustable
Fluorescence Display Value 0.00-600.00
Data Transmission USB 2.0
Size(W×D×H)(mm) 442×392×250
Shipping Size(W×D×H)(mm) 535x500x380
N.W./G.W. (kg) 10/15

Reviews

There are no reviews yet.

Be the first to review “Fluorescence Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Fluorescence Spectrophotometer removeEppendorf Pipette Tip 20ul Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
NameFluorescence Spectrophotometer removeEppendorf Pipette Tip 20ul Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer removeErma B-111 Bilirubin Meter remove
ImageEppendorf Pipette Tip 20ul Per Pack
SKUSF1033560084-136SF1033560084-30SF1033560060-1SF1033560084-129SF1033560084-6
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

$9.50

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-FL96P This compact fluorescence spectrophotometer is designed to provide high sensitivity fluorescence detection during quantification of nucleic acids and is easy to operate.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Fluorescence Spectrophotometer Features:
SP-FL96P fluorescence spectrophotometer is so sensitive that it has become an important analytical method in measurement analysis.
  • Provides wavelength, time scanning (kinetic analysis) and quantitative analysis functions.\
  • 365nm excitation wavelength Raman peak S/N≥150 for water in 1cm quartz fluorescence cuvette High-performance sensitivity simplifies the measurement of low detection samples.
  • 17 levels of gain adjustment are selectable for emission spectrum scanning, including high-speed low signal-to-noise ratio scanning and precision scanning. Full spectrum scanning can be completed within 1 second.
  • Intelligent pre-scan function for fast detection of spectral information of unknown samples. And it can automatically ignore the effect of scattering peaks and harmonic peaks.
  • Support offline mode and online mode.
  • 150W xenon lamp and power supply to ensure high stability and a wide spectral range of testing.
  • The normalization feature of fluorescence value can make the results of different fluorescence comparable.
  • Optional PC qualitative and quantitative software package with expandable time scanning, wavelength scanning, graphical calculation and storage access.
 
Fluorescence Spectrophotometer Specifications:
Model SP-FL96P
Light Source Hamamatsu 150W Xenon lamp
Exciting Optical Filters Interference optical filter
Emission Monochromator C-T diffraction grating
Emission Wavelength 200-900nm
Emission Bandwidth 10nm
Sensitivity S/N≥150(P-P)
Linear ≥0.995
Stability Better than 1.5%/10min
Power 220V±22V; 50Hz±1Hz
Response Time (0.1-4)s 6 stages adjustable
Fluorescence Display Value 0.00-600.00
Data Transmission USB 2.0
Size(W×D×H)(mm) 442×392×250
Shipping Size(W×D×H)(mm) 535x500x380
N.W./G.W. (kg) 10/15
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
Twenty Five (25) Test Strip per PackSkyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare