Fluorescence Spectrophotometer

$0.00

Shipped From Abroad

Model : SP-FL96P

This compact fluorescence spectrophotometer is designed to provide high sensitivity fluorescence detection during quantification of nucleic acids and is easy to operate.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-69
Brands:: Scitek

Description

Fluorescence Spectrophotometer Features:

SP-FL96P fluorescence spectrophotometer is so sensitive that it has become an important analytical method in measurement analysis.

  • Provides wavelength, time scanning (kinetic analysis) and quantitative analysis functions.\
  • 365nm excitation wavelength Raman peak S/N≥150 for water in 1cm quartz fluorescence cuvette High-performance sensitivity simplifies the measurement of low detection samples.
  • 17 levels of gain adjustment are selectable for emission spectrum scanning, including high-speed low signal-to-noise ratio scanning and precision scanning. Full spectrum scanning can be completed within 1 second.
  • Intelligent pre-scan function for fast detection of spectral information of unknown samples. And it can automatically ignore the effect of scattering peaks and harmonic peaks.
  • Support offline mode and online mode.
  • 150W xenon lamp and power supply to ensure high stability and a wide spectral range of testing.
  • The normalization feature of fluorescence value can make the results of different fluorescence comparable.
  • Optional PC qualitative and quantitative software package with expandable time scanning, wavelength scanning, graphical calculation and storage access.

 

Fluorescence Spectrophotometer Specifications:
Model SP-FL96P
Light Source Hamamatsu 150W Xenon lamp
Exciting Optical Filters Interference optical filter
Emission Monochromator C-T diffraction grating
Emission Wavelength 200-900nm
Emission Bandwidth 10nm
Sensitivity S/N≥150(P-P)
Linear ≥0.995
Stability Better than 1.5%/10min
Power 220V±22V; 50Hz±1Hz
Response Time (0.1-4)s 6 stages adjustable
Fluorescence Display Value 0.00-600.00
Data Transmission USB 2.0
Size(W×D×H)(mm) 442×392×250
Shipping Size(W×D×H)(mm) 535x500x380
N.W./G.W. (kg) 10/15

Reviews

There are no reviews yet.

Be the first to review “Fluorescence Spectrophotometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsFluorescence Spectrophotometer removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeMotic BA210 Series Biomedical Microscope removeAvalun LabPad Device removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameFluorescence Spectrophotometer removeErma B-111 Bilirubin Meter removeAGD Erma EL-120 ELectrolyte Analyzer removeMotic BA210 Series Biomedical Microscope removeAvalun LabPad Device removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
ImageAvalun Labpad machine
SKUSF1033560130127-69SF1033560084-6SF1033560084-125SF1033560084-78SF1033560084-65SF1033560084-30
Rating
Price

$0.00

$715.00

$1,320.00

$0.00

$0.00

$9.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model : SP-FL96P This compact fluorescence spectrophotometer is designed to provide high sensitivity fluorescence detection during quantification of nucleic acids and is easy to operate.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Fluorescence Spectrophotometer Features:
SP-FL96P fluorescence spectrophotometer is so sensitive that it has become an important analytical method in measurement analysis.
  • Provides wavelength, time scanning (kinetic analysis) and quantitative analysis functions.\
  • 365nm excitation wavelength Raman peak S/N≥150 for water in 1cm quartz fluorescence cuvette High-performance sensitivity simplifies the measurement of low detection samples.
  • 17 levels of gain adjustment are selectable for emission spectrum scanning, including high-speed low signal-to-noise ratio scanning and precision scanning. Full spectrum scanning can be completed within 1 second.
  • Intelligent pre-scan function for fast detection of spectral information of unknown samples. And it can automatically ignore the effect of scattering peaks and harmonic peaks.
  • Support offline mode and online mode.
  • 150W xenon lamp and power supply to ensure high stability and a wide spectral range of testing.
  • The normalization feature of fluorescence value can make the results of different fluorescence comparable.
  • Optional PC qualitative and quantitative software package with expandable time scanning, wavelength scanning, graphical calculation and storage access.
 
Fluorescence Spectrophotometer Specifications:
Model SP-FL96P
Light Source Hamamatsu 150W Xenon lamp
Exciting Optical Filters Interference optical filter
Emission Monochromator C-T diffraction grating
Emission Wavelength 200-900nm
Emission Bandwidth 10nm
Sensitivity S/N≥150(P-P)
Linear ≥0.995
Stability Better than 1.5%/10min
Power 220V±22V; 50Hz±1Hz
Response Time (0.1-4)s 6 stages adjustable
Fluorescence Display Value 0.00-600.00
Data Transmission USB 2.0
Size(W×D×H)(mm) 442×392×250
Shipping Size(W×D×H)(mm) 535x500x380
N.W./G.W. (kg) 10/15
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
The BA210 series is a line of basic biological microscopes manufactured by Motic. The unit is equipped with Motic Infinity Optics (CCIS®, offering quality performance in the fields of education and training. The device features a coaxial coarse and fine housing with a quadruple reverse-mounted nose piece. Its contrast methods, such as phase contrast, polarization and dark field, are easily performed through optional accessories. Technical applications: Biomedical Type: Optical Observation technique: Dark field Magnification: 4 unit, 10 unit, 40 unit, 100 unit  
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare