FOCUS ADV PLUS MICROSCOPE

$0.00

Shipped From Abroad

FOCUS ADVANCED PLUS microscope, a line of equipment specially designed in detail, to meet the most  demanding standards of Ophthalmological and ENT surgical procedures. Microsurgeries currently require cutting-edge technology with the ability to perform extremely complex procedures in an agile and simple way. Through the Electromagnetic Brake, activated by a button, any and all positioning of the microscope can be done with complete accuracy, comfort and lightness. This ensures less effort and ease during all surgical procedures. For optimizing surgical processes, the NEVRO microscope is the most efficient and advanced.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013091-7
Brands:: DFV

Description

Description

Electromagnetic Brake

Through the electromagnetic brakes, any and all positioning of the microscope can be done with total precision and comfort. Guaranteeing less effort, ease and time optimization.

LCD screen

The touch screen LCD display is used to view and activate all equipment settings. With its touch screen, all controls can be performed with a simple touch.

Pedal control

The automation of functions, with their control through a multitasking pedal, allows the Ophthalmologist and Otorhinolaryngologist complete freedom of their hands during the surgical procedure.

Reviews

There are no reviews yet.

Be the first to review “FOCUS ADV PLUS MICROSCOPE”

Your email address will not be published. Required fields are marked *

Quick Comparison

FOCUS ADV PLUS MICROSCOPE removeHandheld Digital Auto-refractometer removeAutomatic Computer Goldmann (Visual Field Analyzer) removePortable Rebound Tonometer removeRetinoscope removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan remove
NameFOCUS ADV PLUS MICROSCOPE removeHandheld Digital Auto-refractometer removeAutomatic Computer Goldmann (Visual Field Analyzer) removePortable Rebound Tonometer removeRetinoscope removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan remove
ImageMecan AutoSight MCE-900 Handheld Digital AutorefractometerMecan SW-500 Portable Rebound TonometerMecan YZ24 Streak RetinoscopeMecan SW-1000 Ophthalmic Ultrasound Scanner-A-Scan
SKUSF103356013091-7SF1033560107-2SF103356013013SF1033560107-17SF1033560107-12SF1033560107-27
Rating
Price

$0.00

$0.00

$3,850.00

$1,815.00

$165.00

$1,815.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
FOCUS ADVANCED PLUS microscope, a line of equipment specially designed in detail, to meet the most  demanding standards of Ophthalmological and ENT surgical procedures. Microsurgeries currently require cutting-edge technology with the ability to perform extremely complex procedures in an agile and simple way. Through the Electromagnetic Brake, activated by a button, any and all positioning of the microscope can be done with complete accuracy, comfort and lightness. This ensures less effort and ease during all surgical procedures. For optimizing surgical processes, the NEVRO microscope is the most efficient and advanced.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad AutoSight 900 is a portable vision screener for patients at any age. Its working principle is the refraction of light.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
Features: The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems.   Delivery & Availability: Typically 7-14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check archive
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Content
Description
Electromagnetic Brake Through the electromagnetic brakes, any and all positioning of the microscope can be done with total precision and comfort. Guaranteeing less effort, ease and time optimization. LCD screen The touch screen LCD display is used to view and activate all equipment settings. With its touch screen, all controls can be performed with a simple touch. Pedal control The automation of functions, with their control through a multitasking pedal, allows the Ophthalmologist and Otorhinolaryngologist complete freedom of their hands during the surgical procedure.
Handheld Digital Auto-refractometer(AutoSight 900) is a portable vision screener for patients at any age. Its working principle is the refraction of light. Optical rays are focused on a sensor after passing through the eye's refractive system. The spherical power, cylindrical power, and axis of both eyes can be obtained by digital signal processing. Features of Handheld Digital Auto-refractometer:
  • Quick: Automatic and convenient. Press the button at the working distance (35cm/14in) and that's it. The result will be automatically shown in 5 seconds.
  • Accurate: Objective measurement of diopter is obtained from optical signal. The result is not affected by various external factors.
  • Intelligent: Detects multiple eye problems in one measurement including myopia, hyperopia, astigmatism and anisometropia
Technical Specifications of Handheld Digital Auto-refractometer:
Item Range Interval Tolerance
Spherical (S) Myopia Mode -9.00D~ +2.50D 0.25D ±0.50D or ±20% (whichever is greater)
Normal Mode -6.00D  ~ +8.00D
Cylindrical(C) -3.00D~0.00D 0.25D ±0.50D or ±20% (whichever is greater)
Axis(A) 0°~180° ±5°
 
The Bio-1000 automated perimeter absorbs the advantages of international advanced perimetry devices. It comprises the highly integrated computer, optics, machinery and electronics systems. Incorporated with the advanced configuration, comprehensive software inspection categories, and strictly in accordance with international Goldman standard, it provide scientific means for glaucoma, fundus disease, visual pathway injury and neurological diseases. Feature:         * Comprehensive real-time monitoring,Heiji-krakau physiological blind spot monitoring,gaze tracking/head position tracking,automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection. * Personalized design,accurate clinical analysis,accurate and repid examination strategy. * Under international Goldman standard,providing a variety of classic test procedures and report analysis. Technical Specification:
Inspection range 90°
Inspection distance 30cm
Background light brightness White 31.5abs
Visual target brightness 1abs --- 10000abs
Visual target size Goldmann III
Visual target interval time 200ms
Visual target interval time Stardard or adjustment according to patient reflection
Threshold test model Center5°- 16°,center10°- 68, 24-2, 30-2, 30°- 60°,nasal step
Upper threshold test model 30°-40,30°-76,P-60,60°-81,60°-120,190°-135,nasal side
Special detection strategy Esterman monocular,Esterman binocular,user-customized test,150°driver monocular fast detection, 150°driver monocular standard detection, upper36°detection, blind spot detection, 150° horizontal straightness detection
Pupil size test Automatic
Fixation monitoring Blind spot monitoring, eye position deviation alarm, eyedeviation curve
Enviroment light detection Automatic
Analysis software Reliability analysis,single vision report,triple visionreport,GPA half vision analysis, GPA glaucoma developing analysis, VFI vision index analysis
Operation system Win7 above
 
Click Here To Download Catalogue
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
The product can quickly and precisely measure the astigmatism axis and is one of the necessary instruments in optometry inspection. Features:
  • The filament can be rotated for 360° and move upward and downward. The brightness of the streak can be adjusted.
  • Quickly and precisely measure the astigmatism axis.
  • The light can be converged, radiated, and paralleled.
  • Automatic Power Off function effectively protects the bulb.
  • Two-steps adjustable brightness for bulb: S(Bright) and W(Dark).
Technical Specifications:
Working Distance 1 m
Streak 3 mm-20 mm
Streak Rotation 360°
Illumination Source 3V/2W, halogen bulb
Input Voltage AC 220V±10%, 50Hz±1Hz
Power Consumption 4.5 VA
Feature:
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by a pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check the archive
Technical Specifications:
Model SW-1000 Ophthalmic A Scan Biometer
A Scan
A scan probe 10MHz import small size probe, built-in luminotron
Measuring range 15mm-40mm
Measurement precision ±0. 05mm; with macula lutea trace function
Measurement Anterior chamber depth, lens thickness, vitreous body length, total length and average
Method of measurement immersion and contact
Eye mode Phakic/ Aphakic/Dense/ various IOL
IOL formula SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS
Storage 10 cases, 5 readings each case
Output

A scan waveform and IOL calculation sheet

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar