Handheld Capnograph and Oximeter Capno-H
$0.00
Shipped From Abroad
A handheld carbon dioxide monitor with automatic atmospheric pressure compensation, high accuracy, suitable for various complex environments.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of Kingst Handheld Capnograph and Oximeter Capno-H
- Certification – With FDA certification, CE certification, 1SO9000 certification, the product conforms to RoHS, ETCO2 module conforms to FDA certification
- Compact and Lightweight – 3.5 inch LCD display, 380g weight
- Technique – Using non-scattering infrared gas analysis technology
- Unit – kpa, %, mmHg
- Air pump flow – The air pump flow is adjustable, its range: 50cc/min—250cc/min
- Safety – Patented filter to ensure continuous machine work without obstacles
Specifications
AC Input | 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V type-CUSB adapter Cable. Optional Vehicle 12V to 5V Type-CUSB Charger Lead. |
Battery | Built-in rechargeable lithium battery pack (3.7V, 3500mAH) |
Temperature | 5 to +40 ℃ |
Humidity | 30-75% |
Atmospheric pressure | 86~106kpa |
EtCO2/FiCO2 Range | 0~150mmHg |
Accuracy | ±2mmHg for CO2 range 0 – 40mmHg; ±5% for CO2 range from 41 – 70mmHg; ±8% for CO2 range from 71 – 100mmHg; Over 100mmHg ±10% |
Respiration Rate Range | 3~150 breaths/minute |
Accuracy | ±1% of reading or ±1 rpm whichever is greater |
Size | 72 x 155 x 38mm (W x H x D) |
Weight | Weight on Airway ETT/LMA<25g. Monitor 380g |
Display size | 3.5 inches |
Application Scenarios of Kingst Handheld Capnograph and Oximeter Capno-H
-
Two modes are available: sidestream and mainstream.
- Capno-H can simultaneously measure blood oxygen saturation, pulse rate, ETCO2 and respiratory rate. Its lithium battery can support continuous work at full load for more than 10 hours; Capno-H is available for short and long-term monitoring of adults, pediatrics, and infants. It is ready to use after power on and no need to calibrate.
- Capno-H has automatic atmospheric pressure compensation that can provide accurate monitoring whether in plateau or helicopter rescue.
- With selected interference gas, pulmonary pressure and body temperature compensation to achieve the higher precision.
- With simple maintenance and sturdy structure, Capno-H is suitable for various harsh environments.
Quick Comparison
Settings | Handheld Capnograph and Oximeter Capno-H remove | MediPlus Bain Circuit (Adult) remove | Lab/Ward Coat remove | Agary I.V. Cannula remove | Render SD-M2000B Anesthetic Machine remove | Spinal Epidural Pack remove | ||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Handheld Capnograph and Oximeter Capno-H remove | MediPlus Bain Circuit (Adult) remove | Lab/Ward Coat remove | Agary I.V. Cannula remove | Render SD-M2000B Anesthetic Machine remove | Spinal Epidural Pack remove | ||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||
SKU | SF1033560130170-2 | SF1033560084-21 | SF1033560084-222 | SF1033560084-221 | SF1033560011-10 | SF1033560084-25 | ||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||
Price |
| $28.00 | $11.00 | $7.10 | $4,840.00 |
| ||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
A handheld carbon dioxide monitor with automatic atmospheric pressure compensation, high accuracy, suitable for various complex environments.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In Stock
| In stock
| In stock
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
| Shipped from Abroad
| In Stock
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||
Content | Features of Kingst Handheld Capnograph and Oximeter Capno-H
Specifications
Application Scenarios of Kingst Handheld Capnograph and Oximeter Capno-H
|
|
| I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size. |
Click Here To Download Catalogue | It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Component:
| ||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.