Heating mantle PE-4100M (0.5L) analogue
$0.00
Shipped From Abroad
the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С
Advantages:
– two-zone heating with the possibility of switching off the heating of the top zone
– the heating mantle is equipped with electronic temperature controller
– heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device
– automatic break of the device in case of overheating (the operation returns to normal when the temperature reaches allowable limit)
– metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion
Technical specifications:
– Housing material: steel covered with powder paint resistant to chemical action
– Heating element: fabric fiberglass with nichrome wire
– Maximum heater temperature, °С – 450
– Flask volume, ml – 500
– Weight, kg – 3.3
– Dimensions (LхWхH) – 220х325х120
– Power supply voltage (50/60Hz), V – 220-230
– Power consumption, W – 230
Quick Comparison
Settings | Heating mantle PE-4100M (0.5L) analogue remove | Avalun LabPad Device remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Plastic Urine Container Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Automatic Pipette remove |
---|---|---|---|---|---|---|
Name | Heating mantle PE-4100M (0.5L) analogue remove | Avalun LabPad Device remove | Skyla HB1 POC Clinical Chemistry Auto Analyzer remove | Plastic Urine Container Per Pack remove | Test Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove | Automatic Pipette remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF10335601090 | SF1033560084-65 | SF1033560060-1 | SF1033560084-106 | SF1033560084-30 | SF1033560084-130 |
Rating | ||||||
Price |
|
|
| $8.20 | $9.50 |
|
Add to cart | ||||||
Description | Shipped From Abroad
the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In Stock
Twenty Five (25) Test Strip per Pack
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
|
Content | Purpose: the heating mantle is intended for heating liquids in round-bottomed flasks with the volume of 500 ml within the temperature range from the ambient one to 450°С Advantages: - two-zone heating with the possibility of switching off the heating of the top zone - the heating mantle is equipped with electronic temperature controller - heating element is made of safe fiberglass with nichrome wire which excludes permanent deformation and provides firm adherence to vessel walls to avoid heat losses and improve energy performance of the device - automatic break of the device in case of overheating (the operation returns to normal when the temperature reaches allowable limit) - metal housing of the device is covered with powder paint KARUMEL which provides resistance to adhesion, scratching and corrosion Technical specifications: - Housing material: steel covered with powder paint resistant to chemical action - Heating element: fabric fiberglass with nichrome wire - Maximum heater temperature, °С – 450 - Flask volume, ml – 500 - Weight, kg – 3.3 - Dimensions (LхWхH) - 220х325х120 - Power supply voltage (50/60Hz), V - 220-230 - Power consumption, W – 230 | The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy.
Available Test Panels
Click Here To Download Catalogue |
| Twenty Five (25) Test Strip per Pack | This Automatic Pipette will help you get your lab up and running in no time—at a great price!
Features:
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Reviews
There are no reviews yet.