Horizontal Pressure Steam Autoclave

Ask for Price$0.00

Shipped From Abroad

Horizontal Pressure Steam Autoclave uses saturated steam as the sterilization medium,exhausts the cold air by gravity. So that the saturated steam fully penetrates the surface of the items. By utilizing high-temperature saturated steam under high pressure, it effectively kills all microorganisms and their spores, providing reliable sterilization results. It is considered one of the most effective methods among physical sterilization techniques. It is widely used in fields such as pharmaceuticals, biotechnology, and laboratories for sterilizing items such as dressing/fabrics, medical instruments, rubber, and liquids.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-43
Brands:: Scitek

Description

Horizontal Pressure Steam Autoclave Features:
  1. Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
  2. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected.
  3. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point).
  4. Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water.
  5. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
  6. Electrical circuit safety device for over-current and shortcut protection.
  7. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen.
  8. Built-in steam generator prevents the media from contamination.
  9. Buzzer for working errors and the end of the cycle.
  10. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas.
  11. Optional printer, real-time record sterilization process, error and alarm information.

 

Horizontal Pressure Steam Autoclave Specifications:
Model ST-H60 ST-H80 ST-H100 ST-H135 ST-H150 ST-H185 ST-H200 ST-H300 ST-H450
Capacity 60L 80L 100L 135L 150L 185L 200L 300L 450L
External Size

(WxDxH)(mm)

985x600x1450 985x600x1450 1200x600x1450 1000x710x1550 1330x710x1550 1250x710x1550 1320x710x1550 1350x900x1750 1750x900x1750
Chamber Size

(ØxH)(mm)

Ø386×500 Ø386×700 Ø386×950 Ø500×700 Ø500×780 Ø500×950 Ø500×1000 Ø650×950 Ø650×1360
Chamber

Material

SUS304
Sterilization

Temperature

105~136 ℃
Designed

Temperature

150℃
Max.Working

Temperature

136 ℃
Temp.Accuracy 0.1℃
Temp.Uniformity ≤±0.5℃
Designed

Pressure

0.3Mpa
Sterilization

Pressure

0.23Mpa
Temp. Controller PID control by microprocessor
Display LCD touch screen
Drying Function YES
Drying Time 15min
Sterilization

Program

●Dressings/Fabric program  ●Medical instrument program  ●Rubber program  ●Liquid program  ●DIY program
Power

Consumption

5.7KW 5.7KW 6KW 9.35KW 9.35KW 10.8KW 10.8KW 12KW 20KW
Power Supply 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz
Standard

Sterilization

Shelf

1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs
Optional

Accessories

Printer
Net Weight 105kg 120kg 140kg 225kg 240kg 255kg 265kg 350kg 450kg
Gross Weight 165kg 185kg 210kg 315kg 340kg 365kg 380kg 470kg 570kg
Shipping Size

(WxDxH)(mm)

1280x700x1600 1280x700x1600 1450x700x1600 1300x850x1900 1400x900x1900 1440x930x2020 1490x930x2020 1650x1100x2120 2100x1100x2120

Reviews

There are no reviews yet.

Be the first to review “Horizontal Pressure Steam Autoclave”

Your email address will not be published. Required fields are marked *

Quick Comparison

Horizontal Pressure Steam Autoclave removeErma B-111 Bilirubin Meter removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer remove
NameHorizontal Pressure Steam Autoclave removeErma B-111 Bilirubin Meter removeAvalun 48 INR Microcuvette removeSkyla Hi POC Clinical Chemistry Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer removeiSED Fully Automated ESR Analyzer remove
ImageAvalun 48 INR Microcuvette
SKUSF1033560130127-43SF1033560084-6SF1033560084-74SF1033560060-2SF1033560060-1SF1033560084-129
Rating
Price

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Ask for Price$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Horizontal Pressure Steam Autoclave uses saturated steam as the sterilization medium,exhausts the cold air by gravity. So that the saturated steam fully penetrates the surface of the items. By utilizing high-temperature saturated steam under high pressure, it effectively kills all microorganisms and their spores, providing reliable sterilization results. It is considered one of the most effective methods among physical sterilization techniques. It is widely used in fields such as pharmaceuticals, biotechnology, and laboratories for sterilizing items such as dressing/fabrics, medical instruments, rubber, and liquids.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Horizontal Pressure Steam Autoclave Features:
  1. Overheat protection: Automatically cutting off heating with audible and visual alarming when the autoclave is overheated.
  2. Electric interlock safety: Preventing from starting a cycle if door is not properly locked or from door opening if the chamber is pressurized or the power is disconnected.
  3. Door-temperature interlock safety: Preventing from explosion of liquids if the liquids temperature is not cooled down the safe limit (20℃ lower than the local boiling point).
  4. Anti-burning protection: Automatically cutting off heating with audible and visual alarming when the autoclave is lack of water.
  5. Steam pressure safety valve: Automatically works when the chamber pressure exceeds the limit.
  6. Electrical circuit safety device for over-current and shortcut protection.
  7. Automatic operation of sterilization (heating, sterilization, steam discharge and drying) can be easily set and monitored by the LCD touch screen.
  8. Built-in steam generator prevents the media from contamination.
  9. Buzzer for working errors and the end of the cycle.
  10. Automatic atmospheric pressure adjustment for the installation and operation in plateau areas.
  11. Optional printer, real-time record sterilization process, error and alarm information.
 
Horizontal Pressure Steam Autoclave Specifications:
Model ST-H60 ST-H80 ST-H100 ST-H135 ST-H150 ST-H185 ST-H200 ST-H300 ST-H450
Capacity 60L 80L 100L 135L 150L 185L 200L 300L 450L
External Size (WxDxH)(mm) 985x600x1450 985x600x1450 1200x600x1450 1000x710x1550 1330x710x1550 1250x710x1550 1320x710x1550 1350x900x1750 1750x900x1750
Chamber Size (ØxH)(mm) Ø386x500 Ø386x700 Ø386x950 Ø500x700 Ø500x780 Ø500x950 Ø500x1000 Ø650x950 Ø650x1360
Chamber Material SUS304
Sterilization Temperature 105~136 ℃
Designed Temperature 150℃
Max.Working Temperature 136 ℃
Temp.Accuracy 0.1℃
Temp.Uniformity ≤±0.5℃
Designed Pressure 0.3Mpa
Sterilization Pressure 0.23Mpa
Temp. Controller PID control by microprocessor
Display LCD touch screen
Drying Function YES
Drying Time 15min
Sterilization Program ●Dressings/Fabric program  ●Medical instrument program  ●Rubber program  ●Liquid program  ●DIY program
Power Consumption 5.7KW 5.7KW 6KW 9.35KW 9.35KW 10.8KW 10.8KW 12KW 20KW
Power Supply 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz 380V 50Hz
Standard Sterilization Shelf 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs 1pcs
Optional Accessories Printer
Net Weight 105kg 120kg 140kg 225kg 240kg 255kg 265kg 350kg 450kg
Gross Weight 165kg 185kg 210kg 315kg 340kg 365kg 380kg 470kg 570kg
Shipping Size (WxDxH)(mm) 1280x700x1600 1280x700x1600 1450x700x1600 1300x850x1900 1400x900x1900 1440x930x2020 1490x930x2020 1650x1100x2120 2100x1100x2120
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare