Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130104-11

Description

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm

Reviews

There are no reviews yet.

Be the first to review “Infusion patch”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsInfusion patch removeBistos BT-770-12.1" Touchscreen Patient Monitor removeTimesco Jumper Fingertip Pulse Oximeter removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeMaico TouchTymp MI36 Tympanometry remove2-Function Manual Hospital Bed remove
NameInfusion patch removeBistos BT-770-12.1" Touchscreen Patient Monitor removeTimesco Jumper Fingertip Pulse Oximeter removeFlowMir Disposable Turbine with Cardboard Mouthpiece removeMaico TouchTymp MI36 Tympanometry remove2-Function Manual Hospital Bed remove
ImageBistos BT-770-12.1" Touchscreen Patient MonitorFingertip Pulse OximeterFlowMir Disposable Turbine with Cardboard MouthpieceMaico TouchTymp MI36 Tympanometry and Amp
SKUSF1033560130104-11SF1033560059-1SF1033560084-2SF1033560084-22SF1033560063-10SF1033560084-52
Rating
Price

$0.00

$902.00

$17.00

$145.00

$0.00

$140.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5°

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations. SPECIFICATIONS
  • 12.1“ color TFT touch screen
  • ECG, Resp., SpO2, NIBP, Temp., CO2, IBP, Multi-gas, C.O., Masimo SpO2
  • Precise ECG measurement with pacemaker detection ST segment and 16 types of arrhythmia analysis Double overpressure protection for NIBP Intelligent cuff inflation pressure adjustment
  • Smart Hook/Stand design, provide multiple placement modes Plug & Play Modular IBP& C.O., Modular Printer Multiple configuration options: 4-channel IBP, CO2, invasive C.O., Multi-gas Over 5 hours continuous working on battery 12-15V wide range DC input, suitable for ambulance Capable to connect with central monitoring system HL7 export to clinical information systems (option)
 
Click Here To Download Catalogue
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
Product Size:2125*970*540mm Packing size: 205*96*26cm/2pcs Max loading:180KG(400lb) in movement Backrest tilting From 0°to 75°±5° Footrest tilting From 0°to 40°±5° Standard Accessories: 4pcs 5” standard castor two with brake, 1 pair aluminum side rail, 2pcs ABS head and foot board, 4pcs urine hooks, 2pcs cranks system