Infusion patch

$0.00

Shipped From Abroad

Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130104-11

Description

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm

Reviews

There are no reviews yet.

Be the first to review “Infusion patch”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsInfusion patch removeMaico TouchTymp MI36 Tympanometry removeTimesco Jumper Fingertip Pulse Oximeter removeAmbu Bag with Reservior removeWeight and Height Scale removeMIR Spirolab Spirometer remove
NameInfusion patch removeMaico TouchTymp MI36 Tympanometry removeTimesco Jumper Fingertip Pulse Oximeter removeAmbu Bag with Reservior removeWeight and Height Scale removeMIR Spirolab Spirometer remove
ImageMaico TouchTymp MI36 Tympanometry and AmpFingertip Pulse OximeterMIR Spirolab Spirometer
SKUSF1033560130104-11SF1033560063-10SF1033560084-2SF1033560084-41SF1033560084-107SF1033560084-13
Rating
Price

$0.00

$0.00

$17.00

$17.00

$69.40

$2,101.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Other product series of infusion patches are used to solve the problem that existing infusion patches may cause pain when separated, or cannot quickly press the needle hole with a cotton swab, causing bleeding and discomfort to the patient, affecting the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is provided on the longitudinal substrate, a fixing groove is provided on the silicone gel, a disinfection pad is provided on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. In the infusion patch of this utility model, the infusion needle can be set in the fixed groove when in use, and there will be no pain when separating the infusion patch. In addition, a disinfection pad is provided on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation and the like of the needle eye caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use. PARMETERS Infusion Patch
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
  Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock This weight and height scale has two functions, the body weight and height measuring. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Pediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Product details

The infusion patch is used to solve the problem that the existing infusion patch may cause pain when being separated, or that the needle hole cannot be quickly pressed with a cotton swab, causing bleeding and causing discomfort to the patient, which affects the recovery of the needle hole. It includes: a T-shaped substrate, the T-shaped substrate is composed of a vertically arranged horizontal substrate and a longitudinal substrate, a layer of silicone gel is arranged on the longitudinal substrate, a fixing groove is arranged on the silicone gel, a disinfection pad is arranged on the horizontal substrate, the T-shaped substrate is a PU film, and the fixing groove is composed of a needle handle fixing groove and a needle body fixing groove. The depth of the needle handle fixing groove is not more than 3mm, and the depth of the needle body fixing groove is not more than 0.5mm. When using the infusion patch of the utility model, the infusion needle can be set in the fixing groove, and no pain will be generated when separating the infusion patch. In addition, a disinfection pad is arranged on the infusion patch, which effectively prevents the problems of redness, swelling, suppuration, inflammation, etc. of the needle hole caused by incomplete disinfection before acupuncture. It is convenient and comfortable to use.

Product parameters

Product name Part Number Dimensions (cm)
Medical breathable tape W125 1.25cm×9.14m Non-woven fabric
W250 2.5cm×9.14m non-woven fabric
E125 1.25cm×9.14m PE punching
E250 2.5cm×9.14m PE punching
Tourniquet ZCC-20 2×35cm flat
cummerbund 8×42cm
Swimming stickers B0607S 6×7cm
cummerbund C0407 4×7cm
TouchTymp MI 36 combines diagnostic middle ear analyzer and audiometry tests in one exceptional device. The full 10.4" touchscreen with its user-friendly interface guarantees a unique intuitive operation and allows to quickly change parameters. You can easily switch between the tests without reorganizing from one to another device and beneft from its small footprint when facing limited desk space. touchTymp MI 36 really improves your workflow every day. FEATURES AT A GLANCE
  • Combo device with small footprint
  • Customizable to suit individual needs
  • High resolution and quick screen transitions
  • Full touch-based interface for intuitive handling
  • Probe tone 226 Hz, 678 Hz, 800 Hz
  • Optional high-frequency probe tone 1 kHz
  • Acoustic reflex stimuli 500 Hz,1 kHz, 2 kHz, 4 kHz, BB, HP, LP (ipsilateral and contralateral)
  • Reflex Decay test (ipsilateral and contralateral)
  • ETF test for intact and perforated eardrums
  • Air conduction audiometry
  • Bone conduction audiometry
  • Built-in printer or data transfer to PC
  • Optional MAICO Sessions PC Software connectable with OtoAccess® or Noah patient database for easy data management
Comprehensive test protocols
  • Our touchTymp MI 36 provides comprehensive standard protocols for immediate operation of screening and diagnostic test processes: tympanometry with 226 Hz, tympanometry with automatic or fxed acoustic reflexes, reflex decay, Eustachian tube function testing (ETF) plus air conduction and bone conduction audiometry. The optional high-frequency probe tone of 1 kHz is ideal for providing reliable results when testing newborns
Stay focused on your patients
  • The unique touchTymp light bar on our shoulder box probe provides a real-time progression of the immittance test. The shoulder box can easily be clipped to your patient's top for controlled handling of the diagnostic probe. The light indicator shows you which ear is tested and the test result.
Printing made easy
  • Print test results instantly by using the touchTymp built-in printer. Place the shoulder box into its holder to automatically start printing. You can transfer the results to a PC to allow long term storage, full page printout and PDF creation for EMR integration.
Compatible to Sessions: Get ready for fast data transfer!
  • Use the touchTymp MI 36 with our intuitive data transfer solution Sessions, for easy management and visualization of your immittance measurements.
  TECHNICAL SPECIFICATION Tympanometry
  • Probe Frequency - 226 Hz ± 1 %, 85 dBSPL ± 1.5 dB, 678 Hz ± 1%, 72 dBSPL ± 1.5 dB, 800 Hz ± 1%, 70.5 dBSPL ± 1.5 dB
  • Optional High Frequency - 1 kHz ± 1%, 69 dBSPL ± 1.5 dB
  • Pressure Range - -600 to + 400 daPa
  • Accuracy of Pressure - ± 5 % or ± 10 daPa
  • Volume Range - 0.0 to 6.0 ml (compensated)
  • Compliance Range - 0.1 to 8.0 ml at 226 Hz, 0.1 to 15.0 mmho at 678, 800 and 1000 Hz
  • Accuracy of Volume - ± 5 % or 0.1 ml
  • Test Time Measurement - 3 - 5 seconds
Acoustic Reflexes
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Test Methods - Ipsilateral, contralateral
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
  • Level Setting - Automatic, fxed
  • Ipsilateral Reflex - Test With AGC
Reflex Decay
  • Standard - Probe frequency 226 Hz
  • Test Frequencies - 0.5, 1, 2, 4 kHz ± 1 %
  • Test Noise - BB, LP, HP
  • Level Ipsilateral - 70 to 105 dBHL
  • Level Contralateral - 70 to 120 dBHL
Eustachian Tube Function
  • Test Methods - Intact and perforated
  • Pressure Range - -600 to + 400 daPa
Audiometry
  • Test Signals - Sinus and warble tone, (pulsed and continuous)
  • Test Frequencies - 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz (125 Hz excluded
  • from bone conduction test frequencies)
  • Level Steps - 5 or 1 dB
  • Hearing Level Range AC - -10 to 120 dBHL
  • Hearing Level Range BC -  -10 to 80 dBHL
  • Masking Noise - Narrow band and white noise
Device General
  • Display - 10.4" Graphic LED-Display with resistive touchscreen
  • PC Interface - USB
  • Probe - Lightweight diagnostic Shoulder-Box with built-in control light and switch
  • Printer - Fast 4 inch thermal printer
  • Power Supply - Mains 100 to 240 V~ ± 10 %, 50 - 60 Hz ± 10 %
  • Dimensions / Weight - W 30 x D 34.5 x H 14.8 cm / 3.2 kg
  • Languages - English, German, Spanish, French, Polish, Turkish, Russian, Chinese
 
Click Here To Download Catalogue
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
Ambu Bag with Reservior: The ventilation bag is highly reactive with fast recoil and excellent stroke volume which help relieving fatigue to the rescuer. The thin-walled compression bag provides an excellent feel of lung compliance and helps avoid excessive ventilation that could damage the lungs.
Features:
  • Brand: OEM
  • Item No.: AM-DMR-M06-0/1/4
  • Color: Green
  • Size: Adult/Pediatric/Infant
  • Material: Disposable
  • Application: Emergency Resuscitation
  • MOQ: 300
  • Lead Time: 60 days
  • Shipping Terms: FOB
  • Packaging Details: Each set is packed into a white PP box
  • Carton Size: 57 x 34 x 46 CM / 12 SETS
  • Shipping Weight: 9.8 Kilos
  Technical Specifications:
Type Infant Pediatric Adult
Patient weight ≤10kg 10kg-40kg >40kg
Stroke volume 150ml 400ml 800ml
Resuscitator volume 280ml 600ml 1650ml
Dimensions L x D 135 x 75mm 146 x 100mm 212 x 131mm
Resuscitator weight 350g 410g 600g
Pressure limiting valve 40cmH2O 40cmH2O 60cmH2O
Inspiratory resistance <5cmH2O (at 50L/min)
Expiratory resistance <5cmH2O (at 50L/min)
Bag volume 1600ml 1600ml 2000ml
Patient connector ISO5356-1:φ22/15mm Male/Female
Recommended operating temperature -18℃~+50℃
Storage Tested at -40℃ and 60℃
 
 
This weight and height scale has two functions, the body weight and height measuring.
Model NO.: FM-S120
Application: Commercial Scale, Special Scales
Display Type: Analog
Function: Weighing Scale
Structure: Electronic Scale
Shape: Square
Maximum Weight: 120kg
Measuring Range: 70-190cm
Min. Division: 0.5cm
Tolerance: +/- 0.5cm
Size of Platform (L* W): 280*380 mm
Minimum Scale: 0.5kg
Trademark: FULLMEDI
Transport Package: Wooden Case / Carton
Specification: Weight 14kg
Origin: China
Spirometry test:
FVC, VC, MVV, PRE/POST Bronchodilator comparison with a wide range of selectable parameters. Paediatric Incentive for Spirometry. Each function can be easily activated by a simple touch on the bar menu Stand Alone Mode. Colour screen Touchscreen 7 inches TFT display Database up to 10,000 Spirometry tests or 900 hours of Oximetry recording coupled with powerful and flexible search services. Optional function available: Oximeter with adult or paediatric finger probe. Long life Rechargeable Battery. Available with both DISPOSABLE or REUSABLE turbine flowmeter. PC based mode, using WinspiroPRO® Bluetooth® 2.1 and USB Connectivity Wireless or via cable Real Time test directly on your PC. Winspiro PRO® PC software provides Real Time Flow/Volume and Volume/Time curves with PRE/POST Bronchodilator comparison on your PC. Includes free online updates. Paediatric Incentive for Spirometry with wide choice of pictures and animations. Spirometry test after drug adminitration Bronchodilator Reversibility, Bronchial Challenge with FEV1-response curve with protocols for both Methacholine and Mannitol. Quanjer 2012-GLI Predicted values with LLN and Z-score Patient Trend Charts for easy follow-up Search engine for instant access to database. Wide choice of communication protocols for integration with EMR.
Spirometry parameters: FVC, FEV1, FEV1/FVC, FEV1/VC, PEF, FEF25, FEF50, FEF75, FEF25–75, FEF75–85, Lung Age, Extrapolated Volume, FET, Time to PEF, FEV0.5, FEV0.5/FVC, FEV0.75, FEV0.75/FVC, FEV2, FEV2/FVC, FEV3, FEV3/FVC, FEV6, FEV1/ FEV6, FEV1/PEF, FEV1/ FEV0.5, FIVC, FIV1, FIV1/FIVC, PIF, FIF25, FIF50, FIF75, FEF50/FIF50, VC, IVC, IC, ERV, IRV, Rf, VE, VT, tI, tE, VT/tI, tE/tTOT, MVV (measured), MVV (calculated).  