Internal Sidestream ETCO2 Sensor LH820

$0.00

Shipped From Abroad

LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130174-4
Brands:: Prior-care

Description

Features of Internal Sidestream ETCO2 Sensor LH820
  • Suitable for incubated and non-incubated patients.
  • Plug and play, long service life
  • No calibration required
  • Barometer pressure: CO2, N2O, HE compensation for accurate measurement
  • Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
  • Checking and confirming ET tube placement
  • Detecting ventilator airway connection
  • Fully compatible with Respironics module’s protocol
  • Customized connector

 

Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading,
41-70mmHg @ ±5% of reading,
71-100mmHg @ ±8% of reading,
101-150mmHg @ ±10% of reading.
Respiration 3 – 120 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH

 

Compatible Brands:
 

 

Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo

Reviews

There are no reviews yet.

Be the first to review “Internal Sidestream ETCO2 Sensor LH820”

Your email address will not be published. Required fields are marked *

Quick Comparison

Internal Sidestream ETCO2 Sensor LH820 removeLab/Ward Coat removeAnesthetic Face Mask removeAgary I.V. Cannula removeMediPlus Bain Circuit (Adult) removeRender SD-M2000D Anesthetic Machine remove
NameInternal Sidestream ETCO2 Sensor LH820 removeLab/Ward Coat removeAnesthetic Face Mask removeAgary I.V. Cannula removeMediPlus Bain Circuit (Adult) removeRender SD-M2000D Anesthetic Machine remove
Image
SKUSF1033560130174-4SF1033560084-222SF1033560084-141SF1033560084-221SF1033560084-21SF1033560011-15
Rating
Price

$0.00

$11.00

$8.00

$7.10

$28.00

$5,940.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

LH820 is an internal plug-and-play sidestream ETCO2 sensor. It does not occupy any host space and connects to the host just with one eight-pin plug. Measuring respiration rate, ETCO2 concentration, inspired CO2 concentration. generally used in patient monitors and anesthetic machines. With a sampling rate low to 50 mL/min, it is ideal for use on adult, pediatric, and infant patients; patients undergoing procedural sedation; and short-term monitoring of intubated patients.

Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from Abroad
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Internal Sidestream ETCO2 Sensor LH820
  • Suitable for incubated and non-incubated patients.
  • Plug and play, long service life
  • No calibration required
  • Barometer pressure: CO2, N2O, HE compensation for accurate measurement
  • Monitoring the patient’s real-time ETCO2, respiration rate, and inspired CO2
  • Checking and confirming ET tube placement
  • Detecting ventilator airway connection
  • Fully compatible with Respironics module's protocol
  • Customized connector
 
Specifications of Internal Sidestream ETCO2 Sensor LH820
Principle NDIR
CO2 Measuring range 0-150mmHg
0  –  19.7 %
0  –  20 kPa
Accuracy 0-40mmHg @ ±2% of reading, 41-70mmHg @ ±5% of reading, 71-100mmHg @ ±8% of reading, 101-150mmHg @ ±10% of reading.
Respiration 3 – 120 BPM; Accuracy: ±1 BPM
Voltage & Power 5.0VDC ±5%, 600mA (Sensor Average Power Consumption Less than 1.2W)
Interface RS232, TTL (customized)
Temp & Humidity Operating: 0º to 40°, 10 to 90% RH,
Storage: -40º to 70ºC, <90% RH
 
Compatible Brands:
 

 
Philips Nihon Kohden Mindray Biolight
Bionet, Edan, Yonker, Infinium, DRE, Axia Surgical Contec Comen Masimo
  • This white coat laboratory coat is a knee-length overcoat/smock is perfect for professionals in the medical field or by those involved in laboratory work.
  • This garment is Easy to wash and made from a cotton polyester blend, allowing it to be washed at high temperature and make it easy to see if it is clean.
  • Easy to wash.
Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection. Features:
  • Soft cushion for patient comfort and air tight fit
  • Clear flexible housing and cushion for good patient visibility
  • Four sizes available, from small adultl to extra large adult
  • Each mask supplied with color-coded hook ring.
I.V Cannula with wings & injection port 24G/19mm, 0.70mm/20ml/min Injection port with unidirectional valve for facilitating extra medication and preventing back flow. Specially engineered recessed plug with protective ring to avoid risk of contamination. Angle & grooved wings for easy cannulation and to prevent rolling of cannula over patient body. Colour coded cap for easy identification of guage size.
  • Provided with 22mm Corrugated tube of length 1.6m
  • APL Valve
  • 2 L Antistatic Rebreathing bag
  • 6mm Green PVC tube of length 1.6m
Features:
  • Contains Output interface for Anesthesia information management system.
  • Complete with backup battery for working more than 120 minutes.
Click Here To Download Catalogue
   
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare