Leica Rotary Microtome

$0.00

Shipped From Abroad

The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.

Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560084-167

Description

The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.

Features:

  • Compact, ergonomic design
  • Ergonomically designed handwheel handle
  • Smooth-running handwheel with integrated quick-lock mechanism for safety
  • Enclosed micrometer feed mechanism
  • Low-maintenance cross-roller bearings
  • Two forward and backward coarse feed speeds
  • Alternate trimming and sectioning modes, as indicated on the display
  • Speed control through the cutting window for enhanced efficiency
  • Automatic, variable specimen retraction, depending on sectioning speed
  • Section thickness totalizer and section counter
  • Intuitive control panel
  • Integrated communication display
  • Precise specimen orientation with zero point reference
  • Knife holder design with red colored knife guard
  • Precise lateral knife holder adjustment with click stop settings
  • Spacious and easy-to-clean section waste tray
  • Wide range of accessories

 

Technical Specifications:

Section thickness

Setting thickness setting range: 0.5 – 100 µm

Setting values: from 0.5 – 5 µm in 0.5 µm increments

from 5 – 20 µm in 1 µm increments

from 20 – 60 µm in 5 µm increments

from 60 – 100 µm in 10 µm increments

Trimming section thickness setting range: 1 – 600 µm

Setting values: from 1 – 10 µm in 1 µm increments

from 10 – 20 µm in 2 µm increments

from 20 – 50 µm in 5 µm increments

from 50 – 100 µm in 10 µm increments

from 100 – 600 µm in 50 µm increments

Object feed:  24 mm ± 1 mm, feed motion via step motor

Vertical specimen stroke:  70 mm

Sectioning modes:  4

 

Specimen retraction:

In manual operation:  5 – 100 µm in 5 µm increments, can be turned off

In motorized operation:  varying with the sectioning speed, can be turned of

Electric coarse feed: 300 µm/s and 800 µm/s

Sectioning speed: 0.5 – 420 mm/s ± 10%

Maximum specimen size (L x H x W): 50 x 60 x 40 mm

Specimen orientation horizontal: ±8°, vertical: ±8°

Nominal supply voltages: 100/120/230/240 V AC ± 10%

Nominal frequency: 50/60 Hz

Power draw: 340 VA

 

Dimensions basic instrument

Width (incl. handwheel):  413 mm

Depth (incl. waste tray): 618 mm

Height (with storage area on cover): 305 mm

Weight (without accessories): Approx. 40 kg

 

Dimensions control panel: W x D x H 121 x 166 x 50 mm

Weight: approx. 0.66 kg, approx. 1.45 Ibs

Click Here To Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Leica Rotary Microtome”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsLeica Rotary Microtome removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer removeLittle Sister Table Top Autoclave removeAlcohol Pad Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
NameLeica Rotary Microtome removeAvalun LabPad Device removeSkyla Hi POC Clinical Chemistry Analyzer removeLittle Sister Table Top Autoclave removeAlcohol Pad Per Pack removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter remove
ImageAvalun Labpad machine
SKUSF1033560084-167SF1033560084-65SF1033560060-2SF1033560084-46SF1033560084-64SF1033560084-30
Rating
Price

$0.00

$0.00

$0.00

$1,350.00

$4.25

$9.50

Stock
Availability
Add to cart

DescriptionShipped From Abroad The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentThe fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections. Features:
  • Compact, ergonomic design
  • Ergonomically designed handwheel handle
  • Smooth-running handwheel with integrated quick-lock mechanism for safety
  • Enclosed micrometer feed mechanism
  • Low-maintenance cross-roller bearings
  • Two forward and backward coarse feed speeds
  • Alternate trimming and sectioning modes, as indicated on the display
  • Speed control through the cutting window for enhanced efficiency
  • Automatic, variable specimen retraction, depending on sectioning speed
  • Section thickness totalizer and section counter
  • Intuitive control panel
  • Integrated communication display
  • Precise specimen orientation with zero point reference
  • Knife holder design with red colored knife guard
  • Precise lateral knife holder adjustment with click stop settings
  • Spacious and easy-to-clean section waste tray
  • Wide range of accessories
  Technical Specifications: Section thickness Setting thickness setting range: 0.5 – 100 µm Setting values: from 0.5 – 5 µm in 0.5 µm increments from 5 – 20 µm in 1 µm increments from 20 – 60 µm in 5 µm increments from 60 – 100 µm in 10 µm increments Trimming section thickness setting range: 1 – 600 µm Setting values: from 1 – 10 µm in 1 µm increments from 10 – 20 µm in 2 µm increments from 20 – 50 µm in 5 µm increments from 50 – 100 µm in 10 µm increments from 100 – 600 µm in 50 µm increments Object feed:  24 mm ± 1 mm, feed motion via step motor Vertical specimen stroke:  70 mm Sectioning modes:  4   Specimen retraction: In manual operation:  5 – 100 µm in 5 µm increments, can be turned off In motorized operation:  varying with the sectioning speed, can be turned of Electric coarse feed: 300 µm/s and 800 µm/s Sectioning speed: 0.5 – 420 mm/s ± 10% Maximum specimen size (L x H x W): 50 x 60 x 40 mm Specimen orientation horizontal: ±8°, vertical: ±8° Nominal supply voltages: 100/120/230/240 V AC ± 10% Nominal frequency: 50/60 Hz Power draw: 340 VA   Dimensions basic instrument Width (incl. handwheel):  413 mm Depth (incl. waste tray): 618 mm Height (with storage area on cover): 305 mm Weight (without accessories): Approx. 40 kg   Dimensions control panel: W x D x H 121 x 166 x 50 mm Weight: approx. 0.66 kg, approx. 1.45 Ibs Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Features:
  • Indicator light indicates working state.
  • For 4~6 minutes rapidly sterilizing.
  • Sterilizing temperature and time can be preset.
  • Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
  • Over temperature & over pressure auto-protection.
  • Safe protection of water lacking.
  • Exhaust the cool air automatically.
  • With three stainless steel sterilizing plates.
  • The chamber of the sterilizer is made of stainless steel.
  • Automatically shut off with beep reminding after sterilization.
Technical Specifications:
   MODEL   MC-XB20J MC-XB24J

Sterilizing chamber volume

20L(φ250×420 mm) 24L(φ250×520 mm)
Maximum working pressure 0.22Mpa
Maximum working temperature 134℃
Adjustment of temperature 105-134℃
Timer 0-60 min
Chamber temperature equal ≤ ± 1℃
Source power 1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate 340×200×30 mm (3 piece) 400×200×30 mm (3 piece)
Dimension 480×480×384 mm 580×480×384 mm
Package dimension 700×580×500 mm 800×580×500 mm
 G. W/N.W 44/40 kg

50/45 kg

   
 
 
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
Twenty Five (25) Test Strip per Pack
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare